background image

English

REFLEXOTHERAPY DEVICE

REFLEXOTHERAPY DEVICE

6

Symbol for "Authorized Representative in the European 

Community”

("EU authorized representatve" tag), the tag should include the 

company name and address Of the company authorized bythe 

European Union.

The waste products should behand ledlegally.

BF devices

Upside

Fragile

Keepdry

Stacking

Device's serial number

Protected from touch by fingers and objects greater than 12 
millimeters and protected from water spray less than 15 degrees 
from vertical. 

7

8

9

10

11

12

13

14

IP21

The Relexotherapy Device comes with gel electrodes to activate or relax the muscles. 
Muscular stimulation using electrodes is a technique used to tone, remodel, reaffirm 
and maintain muscle definition. 
1. Connect the electrodes to the main device. 
2. Place the electrodes on the area you wish to treat (arms, legs, abdomen or back). 
3. Select the programme for your purpose: Programme 9 (muscle relaxation) 
or Programme 10 (muscle activation). 
4. Increase the intensity gradually until you feel the impulses (the level of intensity may 
vary in accordance with the sensitivity of the individual).
5

Please do not mantle, repair or rebuild the machine yourself, ormanufacturer will not 

guarantee the repairing and after-sale services

6

If not used for a long time, please remove batteries from the remote controller.

Please make a rubbish classification after use, such as electrode pads, carton box 
and so on.

Model number:AST-300D
This equipment belongs to Type BF of Class Il according to Clause5

Rated: 5 V dc, 1000 mA 
Powered by adaptor: WT0502400 
Rated Voltage: 100-240V 
Rated input: 0.1 A 
Output waveform: Square wave 
Pulse repetition frequencies: 10-100HZ 
Maximum amplitude Of output voltage: 72V 
Software version No:MC0188F-REV-V1.O 

Operation condition: 
10-40 °C
30% RH~75%RH 

860 hpa to 1060 hpa 

   

Store and transport condition: 
0-40 °C 
≤80% RH 
860 hpa to 1060 hPa 

Rated frequency: 50-60Hz 
Rated output: 5v 1000mA 
Pulse duration: 115 

μ

Effect Of load impedance: IK

Ω

Shenzhen OSTO Technology Company Limited 
No.43, Longfeng road,Xinsheng community, 
Longgang street, Longgang district, 
Shenzhen city,Guangdong Prinvice, China

Wellkang Ltd 
SuiteB,29 Harley Street, LONDON WIG 9QR, England,lJnited Kingdo

Storage / Maintenance

Specificaons

Environmental  protection

11

12

Содержание AST-300D

Страница 1: ... or in the sunlight Never use the device when asleep or when going to sleep UNSUITABLE USERS You should consult your doctor prior to using the Reflexotherapy Device if You re pregnant You have a fever The doctor has recommended you rest or you are not feeling well You are convalescing on the doctor s orders You suffer from a chronic illness or cancer You have cerebral lesions clots lacerations tra...

Страница 2: ...nutes THE USE OF THE ELECTRODES If it has fallen into water the device should not be placed in or come into contact with water or other liquids If you feel strange or extremely uncomfortable when using the device turn it off immediately and call your doctor During an electrical storm If you have a damaged or mal functioning plug or cable THE DEVICE SHOULD NOT BE USED IN THE FOLLOWING CONDITIONS En...

Страница 3: ...ting a programme halfway through treatment is not advisable in order to guarantee a greater effect Reflexotherapy Programmes 23 Accupuncture Therapy Massage 1 Accupuncture Pushing 3 Accupuncture Kneading 4 Accupuncture Tapping 8 Pushing Massage 9 Pushing Squeezing 10 Accupuncture Squeezing 11 Accupuncture Hammering 14 Scrapping Pressing 18 Massage Tapping 22 Stoke 20 Rolling Pounding 25 Rolling Kn...

Страница 4: ... or relax the muscles Muscular stimulation using electrodes is a technique used to tone remodel reaffirm and maintain muscle definition 1 Connect the electrodes to the main device 2 Place the electrodes on the area you wish to treat arms legs abdomen or back 3 Select the programme for your purpose Programme 9 muscle relaxation or Programme 10 muscle activation 4 Increase the intensity gradually un...

Страница 5: ...and batch number and so on Examples ABC123 Symbol for DATE OF MANUFACTURE This symbol should be next to number Production date of medical equipment use mark in front of theoroduction date After the adoption of the CE certification CE mark is as followed drawn Its vertical height shall not be less than 5mm clearly visible clear durable the CE conformity assessment procedures are made by a Notified ...

Страница 6: ...el of intensity may vary in accordance with the sensitivity of the individual 5 Please do not mantle repair or rebuild the machine yourself ormanufacturer will not guarantee the repairing and after sale services 6 If not used for a long time please remove batteries from the remote controller Please make a rubbish classification after use such as electrode pads carton box and so on Model number AST...

Страница 7: ...uct has been used beyond its capacity or usefulness abused beaten exposed to humidity treated with any liquid or corrosive substance as well as for any other fault attributable to the consumer If the product has been disassembled modified or repaired by persons not authorized by the official OSITO If the incident is caused by normal wear of the parts due to use The cost of the postage for the coll...

Отзывы: