MANUFACTURER’S WARRANTY

The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. 
We hereby declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/
EU of the European Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and 
of the Council and CE-marking Council Directive 93/68/EEC. This certificate is issued following test carried out on samples 
of the product referred to above.
The manufacturer hereby warrants normal operation of the unit for 60 months after the retail sale date provided the user's 
observance of the transportation, storage, installation, and operation regulations. Should any malfunctions occur in the 
course of the unit operation through the Manufacturer's fault during the guaranteed period of operation, the user is entitled 
to get all the faults eliminated by the manufacturer by means of warranty repair at the factory free of charge. The warranty 
repair includes work specific to elimination of faults in the unit operation to ensure its intended use by the user within the 
guaranteed period of operation. The faults are eliminated by means of replacement or repair of the unit components or a 
specific part of such unit component.

The warranty repair does not include: 

• 

routine technical maintenance

• 

unit installation/dismantling 

• 

unit setup

To benefit from warranty repair, the user must provide the unit, the user's manual with the purchase date stamp, and the 
payment paperwork certifying the purchase. The unit model must comply with the one stated in the user’s manual. Contact 
the Seller for warranty service. 

The manufacturer’s warranty does not apply to the following cases:

• 

User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission 
with missing component parts previously dismounted by the user.

• 

Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user's 
manual.

• 

User’s failure to ensure timely technical maintenance of the unit.

• 

External damage to the unit casing (excluding external modifications as required for installation) and internal 
components caused by the user.

• 

Redesign or engineering changes to the unit.

Содержание OSEF

Страница 1: ...User s manual OSEF AXIAL FAN EN...

Страница 2: ...is a main operating document intended for technical maintenance and operating staff The manual contains information about purpose technical details operating principle design and installation of the...

Страница 3: ...ians with a work permit for electrical units up to 1000V are allowed for installation The present user s manual should be carefully read before beginning works Check the unit for any visible damage of...

Страница 4: ...unit to adverse atmospheric agents rain sun etc Transported air must not contain any dust or other solid impurities sticky substances or fibrous materials Do not use the unit in a hazardous or explos...

Страница 5: ...vision or instruction concerning use of the unit by a person responsible for their safety Children should be supervised to ensure that they do not play with the unit Precautions must be taken to avoid...

Страница 6: ...nsure that the unit is switched off from the supply mains before removing the guard THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC...

Страница 7: ...for connection to single phase AC power mains Power supply parameters are stated on the unit packaging and or the label on the unit casing Ingress protection rating against access to hazardous parts...

Страница 8: ...tional options Z1 base model Z1PC pull cord switch Z1T turn off delay timer Z1PCT pull cord switch and turn off delay timer Z1H humidity sensor and turn off delay timer Z1PIR motion sensor Colour C Ch...

Страница 9: ...f Fig 3 Step 2 Run the power cable to the vent hole Fig 4 Step 3 Remove the front panel from the fan Then remove the circuit board cover Fig 5 Step 4 Mark and drill holes for mounting the fan fasten t...

Страница 10: ...from 0 up to 2 minutes off To adjust the fan turn off delay time turn the control knob Toff clockwise to increase and counter clockwise to decrease the turn off delay time respectively adjustable fro...

Страница 11: ...speed 1 by default The fan switches to the speed 2 when the switch is turned on or a sensor is activated Operation mode 4 two speed The fan is turned off by default The fan starts operating at low spe...

Страница 12: ...ndicator blinks green once in a second the turn on delay time is activated 60 seconds 3 The light indicator glows red the humidity sensor is activated and the fan runs at high speed 4 The light indica...

Страница 13: ...e into contact with electric components TROUBLESHOOTING Problem Possible reasons Troubleshooting When the unit is connected to power mains the fan does not rotate and does not respond to any controls...

Страница 14: ...hinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo Theunitcanbecarriedintheoriginalpackaging...

Страница 15: ...ific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation The faults are eliminated by means of replacement or repair of the...

Страница 16: ...Violation of the unit transportation regulations by the user Violation of the unit storage regulations by the user Wrongful actions against the unit committed by third parties Unit breakdown due to ci...

Страница 17: ...17 EN 1 2 Dimensions mm D B H L L1 OSEF 150 148 214 190 111 32 B D L L1 H...

Страница 18: ...18 EN 3 4 5 6 7 8 9 10 11...

Страница 19: ...run S switch to ON or pull cord switch Fan runs at speed 1 S switch to OFF or pull cord switch S S LT 1 L 2 N 3 LT 1 L 2 N 3 LT 1 L 2 N 3 L N L N L N 150 Z1 speed 2 150 Z1PC speed 2 Fan does not run...

Страница 20: ...L N LT 1 L 2 N 3 LT 1 L 2 N 3 LT 1 L 2 N 3 150 Z1 speed 1 and 2 150 Z1PCT speed 1 and 2 speed 1 and 2 Fan does not run S switch to ON or pull cord switch Speed switch Fan runs at speed 1 Fan runs at...

Страница 21: ...ay timer Yes No Fan runs at speed 1 S switch to ON or pull cord switch Fan does not run S switch to ON or pull cord switch Activation of turn off delay timer 0 2 minutes S switch is OFF during countdo...

Страница 22: ...turn on delay timer 0 2 minutes S switch is OFF during countdown of turn on delay timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull cord...

Страница 23: ...FF during countdown of turn on delay timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull cord switch Fan does not run Fan runs at speed 2 F...

Страница 24: ...ch is OFF during countdown of turn on delay timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull cord switch Fan runs at speed 2 Fan runs at...

Страница 25: ...during countdown of turn on delay timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull cord switch Fan runs at speed 2 Fan runs at speed 1...

Страница 26: ...ch to ON or pull cord switch Yes Humidity exceeds set point No Fan runs at speed 1 Fan runs at speed 1 Fan runs at speed 1 Fan does not run Fan runs at speed 2 Fan runs at speed 1 Fan runs at speed 1...

Страница 27: ...t speed 2 Fan runs at speed 1 No motion detected Activation of turn off delay timer 2 30 minutes Activation of turn off delay timer 2 30 minutes Activation of turn off delay timer 2 30 minutes Fan doe...

Страница 28: ...28 EN 22 23 24 25...

Страница 29: ...29 EN...

Страница 30: ...30 EN...

Страница 31: ...31 EN Quality Inspector s Stamp Manufacture Date Sold by name and stamp of the seller Purchase Date...

Страница 32: ...YESSS_Electrical_235 2EN 01 OSEF 150 C Z1PC Z1H Z1T Z1PCT Z1PIR...

Отзывы: