background image

User’s manual

OSEF

AXIAL FAN

EN  

Содержание OSEF

Страница 1: ...User s manual OSEF AXIAL FAN EN...

Страница 2: ...is a main operating document intended for technical maintenance and operating staff The manual contains information about purpose technical details operating principle design and installation of the...

Страница 3: ...ians with a work permit for electrical units up to 1000V are allowed for installation The present user s manual should be carefully read before beginning works Check the unit for any visible damage of...

Страница 4: ...unit to adverse atmospheric agents rain sun etc Transported air must not contain any dust or other solid impurities sticky substances or fibrous materials Do not use the unit in a hazardous or explos...

Страница 5: ...vision or instruction concerning use of the unit by a person responsible for their safety Children should be supervised to ensure that they do not play with the unit Precautions must be taken to avoid...

Страница 6: ...nsure that the unit is switched off from the supply mains before removing the guard THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC...

Страница 7: ...for connection to single phase AC power mains Power supply parameters are stated on the unit packaging and or the label on the unit casing Ingress protection rating against access to hazardous parts...

Страница 8: ...tional options Z1 base model Z1PC pull cord switch Z1T turn off delay timer Z1PCT pull cord switch and turn off delay timer Z1H humidity sensor and turn off delay timer Z1PIR motion sensor Colour C Ch...

Страница 9: ...f Fig 3 Step 2 Run the power cable to the vent hole Fig 4 Step 3 Remove the front panel from the fan Then remove the circuit board cover Fig 5 Step 4 Mark and drill holes for mounting the fan fasten t...

Страница 10: ...from 0 up to 2 minutes off To adjust the fan turn off delay time turn the control knob Toff clockwise to increase and counter clockwise to decrease the turn off delay time respectively adjustable fro...

Страница 11: ...speed 1 by default The fan switches to the speed 2 when the switch is turned on or a sensor is activated Operation mode 4 two speed The fan is turned off by default The fan starts operating at low spe...

Страница 12: ...ndicator blinks green once in a second the turn on delay time is activated 60 seconds 3 The light indicator glows red the humidity sensor is activated and the fan runs at high speed 4 The light indica...

Страница 13: ...e into contact with electric components TROUBLESHOOTING Problem Possible reasons Troubleshooting When the unit is connected to power mains the fan does not rotate and does not respond to any controls...

Страница 14: ...hinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo Theunitcanbecarriedintheoriginalpackaging...

Страница 15: ...ific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation The faults are eliminated by means of replacement or repair of the...

Страница 16: ...Violation of the unit transportation regulations by the user Violation of the unit storage regulations by the user Wrongful actions against the unit committed by third parties Unit breakdown due to ci...

Страница 17: ...17 EN 1 2 Dimensions mm D B H L L1 OSEF 150 148 214 190 111 32 B D L L1 H...

Страница 18: ...18 EN 3 4 5 6 7 8 9 10 11...

Страница 19: ...run S switch to ON or pull cord switch Fan runs at speed 1 S switch to OFF or pull cord switch S S LT 1 L 2 N 3 LT 1 L 2 N 3 LT 1 L 2 N 3 L N L N L N 150 Z1 speed 2 150 Z1PC speed 2 Fan does not run...

Страница 20: ...L N LT 1 L 2 N 3 LT 1 L 2 N 3 LT 1 L 2 N 3 150 Z1 speed 1 and 2 150 Z1PCT speed 1 and 2 speed 1 and 2 Fan does not run S switch to ON or pull cord switch Speed switch Fan runs at speed 1 Fan runs at...

Страница 21: ...ay timer Yes No Fan runs at speed 1 S switch to ON or pull cord switch Fan does not run S switch to ON or pull cord switch Activation of turn off delay timer 0 2 minutes S switch is OFF during countdo...

Страница 22: ...turn on delay timer 0 2 minutes S switch is OFF during countdown of turn on delay timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull cord...

Страница 23: ...FF during countdown of turn on delay timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull cord switch Fan does not run Fan runs at speed 2 F...

Страница 24: ...ch is OFF during countdown of turn on delay timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull cord switch Fan runs at speed 2 Fan runs at...

Страница 25: ...during countdown of turn on delay timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull cord switch Fan runs at speed 2 Fan runs at speed 1...

Страница 26: ...ch to ON or pull cord switch Yes Humidity exceeds set point No Fan runs at speed 1 Fan runs at speed 1 Fan runs at speed 1 Fan does not run Fan runs at speed 2 Fan runs at speed 1 Fan runs at speed 1...

Страница 27: ...t speed 2 Fan runs at speed 1 No motion detected Activation of turn off delay timer 2 30 minutes Activation of turn off delay timer 2 30 minutes Activation of turn off delay timer 2 30 minutes Fan doe...

Страница 28: ...28 EN 22 23 24 25...

Страница 29: ...29 EN...

Страница 30: ...30 EN...

Страница 31: ...31 EN Quality Inspector s Stamp Manufacture Date Sold by name and stamp of the seller Purchase Date...

Страница 32: ...YESSS_Electrical_235 2EN 01 OSEF 150 C Z1PC Z1H Z1T Z1PCT Z1PIR...