SECTION 5: INSTALL THE STRIKE 

 

SECTION 7: REMOTE SWITCH 

a.  Remote operation of the System may be accomplished by a momentary Switch 

closure. This may be desirable for someone monitoring a protected entrance, 
such as a receptionist. Momentarily pressing the Switch will cause the System 
to go through a normal unlock and lock sequence. If the Switch is held closed, 
the open time will be extended.  

 
b. Connect a twisted pair of wires from the Terminal Block on the PC Board to a 

normally open momentary contact Switch. Plan the route for your wire and the 
access route through the door to the PC Board in the OMNILOCK Module. Plan 
for disconnecting the wires in the module area so that the System can be 
removed from the door to change the Batteries as required.  Refer to Fig.14. 

(Website: WWW.OMNILOCK.COM) 

OMNILOCK

SWITCH 

TWISTED 

PAIR 

OMNILOCK

 

ACCESS CONTROL SYSTEMS 
 

 

SECURITY 

D E V I C E S

 

WARNING: THIS PRODUCT IS NOT WARRANTED FOR 
OUTDOORS USE! 
NOTE: A DOOR-CLOSER IS HIGHLY RECOMMENDED 
FOR USE WITH THIS PRODUCT.  

THIS PRODUCT IS NORMALLY FACTORY-PACKED 

FOR RIGHT-HAND 1-3/4” TO 2” THICK DOORS. 

TO CHANGE HAND OF LOCK, SEE 

INSTRUCTION SECTION 2. 

LOCK 

CONNECTOR 

(Routes through 

the slot in the 

Door) 

SCREW 

POST 

OUTER TRIM 

ASSEMBLY 

INTERCHANGEABLE CORE (I.C.) 

I.C. CORE 
(NOT SUPPLIED) 

CONTROL KEY 

(NOT SUPPLIED) 

I.C. CYLINDER 

 WITH CAM 

NYLON 

WASHER 

 

SCREW  

FLAT HEAD 

#12 X 1”  

(2-REQD) 

STRIKE 

BOX 

STRIKE 

SCREW 

FLAT HEAD 

#12 X 1” (2-REQD) 

WASHER 

THUMB TURN 

INSIDE 

 LEVER  

SCREW, FLAT 

HEAD #6X1/2” 

(2-REQD) 

SCREW  

FLAT HEAD 

#8X2-1/4”  
(2-REQD) 

INSTALLER NOTES: Leave these instructions and other Documents with the User. 

CYLINDER 
WITH CAM 

WAVY 

WASHER 

HOUSING 
ASSEMBLY 

KEY 

SCREW  

PAN HEAD 

#6-32X1/4” 

STANDOFF 

#8-32X1” 

(2-REQD) 

AA ALKALINE 

BATTERY, 1.5V 

(4-REQD) 

BATTERY 

COVER 

  

GASKET 

SEMS #4-40X1/4” 

PAN HEAD 

SCREWS,  
FLAT HEAD 
#8-32X3/8” 
 LG (2-REQD) 

GROUND 
SPRING 

CYLINDER 

COLLAR 

BACK 
PLATE 

ELECTRONICS MODULE 

CONNECTOR 

SPINDLE & SPRING 

ASSEMBLY 

SCREW, PAN HEAD TORX  
#8-32X1-1/2” FOR 2” THICK DOOR 
#8-32X1-1/4” FOR 1-3/4” THICK 
DOOR (2-REQD) 

LOCK 

 

FACE 

PLATE 

 

SCREW, FLAT 

HEAD #10-32 X 2” 

(2 REQD) 

 

INNER INSERT 

ASSEMBLY 

 

SPINDLE & SPRING 

ASSEMBLY 

PG. 8 OF 8 

PG. 1 OF 8 

INSTALLATION INSTRUCTIONS

 

FOR OM100, OM300, 

AND OM500 SERIES

 

NON-WEATHERIZED,

 

MORTISE 

LOCKSETS

 

USING

 

FALCON

 

LM SERIES LOCKS (LEVER) 

 

a.  Draw a vertical line on the Door Frame 1/2 the Door thickness 

from the Door Stop. Refer to Fig.13.  

CAUTION: Allow for paint buildup or weather stripping if required. 

b.  Select the Strike with the proper hand condition and align the 

bottom edge of the Strike Lip with the mark on the Door Frame 
and align the center of the mounting holes in the Strike with the 
vertical line on the frame. Using the Strike as a template, mark the 
Door Frame. 

c.  Using the Strike Box as a template, mark the Door Frame.  

d.  Mortise the Frame to accept the Strike and Strike Box.  

e.  Install the Strike Box and the Strike and secure with the Screws.

 

 

COLLAR 

 

SET 

SCREW 

ALIGNMENT 

MARKS 

 

STRIKE BOX 

SCREW 

#12X1 

STRIKE 

FIG.13 

FIG.14 

 

 

ALIGMENT 

MARKS 

 

SECTION 6: PROGRAM THE LOCK 

IMPORTANT: To avoid unauthorized access, it is important to program a new Master Code. 

For programming instructions refer to the Quick Reference Guide shipped with this product or to the OMNILOCK 
User Guide which may be ordered by calling Customer Service at 619-628-1000 or it may be downloaded from out 
website http:/omnilock.com/files/om135man.pdf 

DOOR HANDLING 

 

RIGHT HAND SHOWN 

DOOR HAND DETERMINED FROM OUTSIDE 

LEFT 
HAND 

RIGHT 
HAND  

INSIDE  

OUTSIDE 

INSIDE 

OUTSIDE 

RIGHT HAND 
REVERSE 
BEVEL 

LEFT HAND 
REVERSE 
BEVEL 

Содержание OM100

Страница 1: ...12 X 1 2 REQD WASHER THUMB TURN INSIDE LEVER SCREW FLAT HEAD 6X1 2 2 REQD SCREW FLAT HEAD 8X2 1 4 2 REQD CYLINDER WITH CAM WAVY WASHER HOUSING ASSEMBLY KEY SCREW PAN HEAD 6 32X1 4 STANDOFF 8 32X1 2 R...

Страница 2: ...R 1 Remove the Face Plate Remove the Deadlocking Bar reverse it and replace it back into the Assembly Push against Blocker Assembly to allow Deadlocking Bar to be easily inserted 2 Replace the Face Pl...

Страница 3: ...PG 3 OF 8 LOCK ASSEMBLY FOOT UPPER RETRACT ARM CYLINDER RETRACT LEVER COUPLING LATCH BOLT SPRING HUB T TURN HUB DEAD LOCKING BAR LOCK FRONT SCREW BLOCKER ASSEMBLY DEAD BOLT PIN FACE PLATE FIG 2...

Страница 4: ...he Lever securely rotate the Rose Assembly counterclockwise slightly past 90 f Reinstall the Plate with the L side up and in Line with the L on the Rose Assembly g Reinstall the Lock Washer and the Nu...

Страница 5: ...ce to locate the horizontal centerline position Mark the Door 3 16 below the bottom of the Strike Lip as illustrated in Fig 4 and draw horizontal centerlines on the Door at this position as illustrate...

Страница 6: ...BLE CONNECTOR RED AND BLACK WIRES CASE ATTACHMENT SCREWS THREADED POST SHANK THUMB TURN INNER INSERT ASSEMBLY SPINDLE SPRING ASSEMBLY OUTER TRIM ASSEMBLY INSIDE SCREW 10 32 X 2 OUTSIDE INSIDE HANDLE S...

Страница 7: ...CS MODULE a Guide the Connectors through the front hole in the Module and place the Module against the Door so that the Standoffs and the Grounding Spring enter their respective holes Refer to Fig 11...

Страница 8: ...Refer to Fig 14 Website WWW OMNILOCK COM OMNILOCK SWITCH TWISTED PAIR INSTALLER NOTES Leave these instructions and other Documents with the User PG 8 OF 8 a Draw a vertical line on the Door Frame 1 2...