SECTION 2 – USER RESPONSIBILITIES, MACHINE PREPARATION, AND INSPECTION
2-10
– JLG Lift–
Overload Sensor Check
Check the overload indicator light/alarm to ensure proper
operation. Wedge a block (P/N: ST2741 - located in the
manual storage container) to activate the overload sensor
and keep it activated. Refer to Figure 2-4.
1.
From the Platform Control Console:
a.
Confirm an audible alarm sounds.
b.
Verify the overload indicator (Red) blinks.
c.
Check that all functions are disabled.
2.
From the Ground Control Panel:
a.
Confirm an audible alarm sounds.
b.
Verify the overload indicator (Red) blinks.
Figure 2-4. Overload Sensor
To
order go
to
Discount-Equipment.com