SECTION 6 - ACCESSORIES
3121606
– JLG Lift –
6-9
All power regulation components are located in a watertight box
connected by cable to the generator. The generator supplies
power when running at the specified speed with the power
switch on (switch is located on platform). A three-pole, 30 Amp
circuit breaker protects the generator from overload.
Generator Output
ANSI Specifications:
• 3-phase: 240 V, 60 Hz, 7.5 kW
• 1-phase: 240 V/120 V, 60 Hz, 6 kW
CE Specifications:
• 3-phase: 240 V, 7.5 kW, 18.3 A, 1.0-pf
• 1-phase: 240 V, 6.0 kW, 26 A, 1.0-pf
• 1-phase: 120 V, 6.0 kW, 50 A, 1.0-pf
Peak:
• 3-phase: 8.5 kW
• 1-phase: 6.0 kW
Accessory Ratings
• 3000 rpm (50 Hz)
• 3600 rpm (60 Hz)
Safety Precautions
DO NOT OVERLOAD PLATFORM.
• Ensure no personnel are beneath platform.
• This factory-installed option is available only on specified
models.
• Keep lanyard attached at all times.
• Do not use electrical tools in water.
• Use correct voltage for tool being used.
• Do not overload circuit.
Preparation and Inspection
• Ensure generator is secure.
• Check condition of belt and wiring.
Operation
Start the engine, then turn on the generator.
Refer to the Miller Generator Technical Manual (PN 3121677) for
more information.