- 15 -
Yes
OTHERS :
※
In order to prevent mechanical trouble, Be sure to lubricate and grease-up
the driving section.
Will the thermo-lamp blink in about 30
miniutes the thermostat is set at 150
℃
.
1.
If the voltage between the SSR terminal 3 and 4 is not DC 2.5V-7V
then the thermo-lamp lights up the thermostat is defective.
2.
If the SSR lamp doesn’t light up, and the temperature doesn’t rise.
The heater is defective.
3.
If the SSR lamp doesn’t off and the temperature doesn’t rise, SSR is
defective.
O.K.
1.
If the thermo-lamp doesn’t light , and the SSR lamp doesn’t off, the thermo-sensor is defective.
2.
if the thermo-lamp and SSR lamp don’t light, the SSR is defective, (the temperature doesn’t fall.)
3.
If the thermo-lamp doesn’t off, thermostat is defective. (The temperature doesn’t fall.)
No
No
Yes
When the belt warps, the belt doesn’t stop running.
Belt warping stop switch is defective.
When turning off the power switch, the belt doesn’t stop running.
The timer doesn’t off.
The time is defective.
Return conveyer doesn’t run.
Tense the tension of return conveyer.
Slipage of V belt
Содержание OP-1200
Страница 2: ...1 Work set Power switch Enter spirit Cooling system...
Страница 4: ...3 1 2 3 4 5 6 A 100...
Страница 5: ...4 B C 7 8 9 10 11...
Страница 6: ...5 0 P C V 30 SSR SSR 150 30 1 SSR 3 4 DC2 5V 7V 2 SSR 3 SSR SSR...
Страница 7: ...6 1 SSR 2 SSR SSR 3 V...
Страница 8: ...7 1 SET SV F OFF SET 2 SET ALI SLH F OFF 3 SET LCK 1 4 SV SV 0000 SV FFFF AL1 AL1 AL1 SHT...
Страница 9: ...8...
Страница 21: ...20...
Страница 22: ...21...
Страница 23: ...22...
Страница 26: ...25...
Страница 29: ...28 NO 5...
Страница 34: ...33 Part list NO 7...
Страница 38: ...37 34 1600B163 1 base for scraper 1...
Страница 39: ...38...
Страница 41: ...40...
Страница 44: ...43 Drum...
Страница 45: ...44...
Страница 46: ...45...
Страница 47: ...46...