Operating manual NR-12-TRS-2    Page: 7 

Installation instructions solenoid valve 

 

The piping system must be cleaned before the valve installation, because dirt will 
malfunction. 

 

If necessary, a strainer should be mounted in front of the valve inlet. 

 

Mechanically clamping the valve housing, for example for non-aligned pipes or 
improper sealing material is to be avoided. 

 

Use only suitable tools. 

 

Do not use the solenoid coil during mounting as a lever arm. 

 

During installation, the flow direction must be observed!

 The brass body is 

labeled near the thread with IN and OUT. The valve closes tightly only in the 
specified direction of flow. In the opposite direction, the solenoid valve may be 
damaged. 

 

The preferred installation location is " solenoid vertical on top ". In this position, the 
wear and contamination risk is lowest. 

 

Electrical connection 

The electrical connection may only be carried out by an authorised electrician taking 
into account the applicable regulations. The protective earth connection is essential. 

The junction box may be inserted or removed only when the power is off. AC 
solenoids are destroyed when operating without armature. 

 

Maintenance

 

Maintenance work must be performed by an expert only when the pipework is 
pressure-free and the magnet is voltage-free. 

 

Trouble shooting 

If the valve does not open or close, the control bores and the armature must be 
cleaned.  

 

We wish you a lot of fun and relaxation in your swimming pool.  

 

Subject to alterations!

 

 

 Mai 2018

 

Содержание NR-12-TRS-2

Страница 1: ...witching cycles which may be too short The submerged electrodes are operated using non hazardous safety low voltage The controller itself has been designed to comply with the currently applicable German VDE and CE regulations Specifications Control system Dimensions 220mm x 219mm x 100mm Operational voltage 230V 50Hz Control system power consumption ca 7VA Switching capacity max 1 1kW AC3 Protecti...

Страница 2: ...ced switching OPEN Dry run protection pump OFF In normal operation the water level varies between the solenoid valve CLOSED and solenoid valve OPEN The height difference is dependent on individual conditions A minimum of 5 cm should be ensured to achieve sufficient sensing distance Electrical power supply The electrical power supply may only be installed by an approved specialist electrician The f...

Страница 3: ...the electrodes the solenoid valve closes freshwater inflow off b Filter pump dry run protection If the water level sinks to below the dry run protection pump OFF submerged electrode due to water losses in the collection reservoir e g due to backflushing the collection reservoir control system switches the filter pump off so that it is not damaged by dry running As soon as the water level rises to ...

Страница 4: ...ing system K4 is activated if necessary see DIP 4 DIP 2 OFF Dry run protection works without time limitation When the water level sinks below the dry run protection electrode the pump K3 is switched off It is only switched on again once the water level has reached minimum operating level Dry run protection time limitation ON Dry run protection works with without time limitation When the water leve...

Страница 5: ...e set using trimmer 2 0 5 60 minutes the pump is switched off and the error message K4 is switched on DIP 4 Group error message OFF Relay K4 is used for group error messaging It is switched on if the dry run protection activates the solenoid valve time limitation activates see DIP 2 the forced switching time limitation activates see DIP 3 inadmissible measured values are detected in the electrodes...

Страница 6: ...ble troubleshooting Caution The service terminal may only be plugged in or unplugged when the control system is switched off Zwg Max Min TRS MV TRS Zwg K4 360s OFF 600s Samm Forced switching Maximum operating level Minimum operating level Dry run protection Water level display Solenoid valve time limitation Dry run protection time limitation Forced switching time limitation Use of contact K4 group...

Страница 7: ...he opposite direction the solenoid valve may be damaged The preferred installation location is solenoid vertical on top In this position the wear and contamination risk is lowest Electrical connection The electrical connection may only be carried out by an authorised electrician taking into account the applicable regulations The protective earth connection is essential The junction box may be inse...

Страница 8: ...Operating manual NR 12 TRS 2 Page 8 ...

Отзывы: