oserio FSC-330 Скачать руководство пользователя страница 6

5

 How to Use

3.1 Weight measurement

1

Place product on stable, flat, solid, non-slippery surface (no carpet).

Tap the measurement platform to turn on product. Welcome message 
will be displayed, as product conducts self-calibration.  

Do not step on measurement platform during this time.

2

WEIGHT

When "0.0" appears on display, step onto measurement platform.

Try and stand as still as possible.

3

WEIGHT

Body weight result will appear on screen once measurement is completed.

Product will automatically shut down after 20 seconds. 
Press and hold SET button to turn off manually.

Select Gender

      

       Male /         Female    

Press SET to confirm.

6

How to Use

3.2 User data setup

AGE

Place product on stable, 
flat, solid, non-slippery 
surface (no carpet). 
Tap to turn on device.

Press SET button.

Use 

▲▼

 to select user 

ID. Press SET to confirm 
selection.

Input Age

Input age using 

▲▼

 buttons.

 

(press and hold buttons to 
advance at a faster speed)

Press SET to confirm.

Input height

Input height using 

▲▼

 buttons. 

(press and hold buttons to 
advance at a faster speed)

Press SET to confirm.

New User

Содержание FSC-330

Страница 1: ...instruction manual at hand all the time for future reference Manufactured by on behalf of Charder Electronic Co Ltd No 103 Guozhong Rd Dali Dist Taichung City 41262 Taiwan R O C Krell Precision Yangz...

Страница 2: ...r of medical product including address Electro medical appliance with attachment for type BF Carefully read this operation manual before setup and commissioning even if you are already familiar with o...

Страница 3: ...der Electronic Co Ltd All rights reserved This user manual is protected by international copyright law All content is licensed and usage is subject to written authorization from Charder Electronic Co...

Страница 4: ...e treated as regular household waste but should be taken to a designated collection points for electronics Further information should be provided by local waste disposal authorities Usage of Results T...

Страница 5: ...elete all measurement data from product NOTE 4 Product Description 2 2 Inserting Batteries Ensure batteries are inserted in correct orientation If batteries are inserted incorrectly product will not f...

Страница 6: ...appear on screen once measurement is completed Product will automatically shut down after 20 seconds Press and hold SET button to turn o manually Select Gender Male Female Press SET to con rm 6 How to...

Страница 7: ...carpet Tap to turn on device Press SET button Use to select user ID Press SET to con rm selection Con rm user data Screen will display personal details for selected ID To change user data please pres...

Страница 8: ...no buttons are touched for 30 seconds NOTE 4 Basal Metabolic Rate BMR 5 Body Age 6 Body Weight Target Weight 9 How to Use 3 3 Conducting Body Fat Measurement Weight result will be displayed on screen...

Страница 9: ...ly exist it is still an important value in assessing change in body composition and health Body Fat Percentage Basal metabolic rate is the minimum required energy to sustain the body s vital functions...

Страница 10: ...Impedance Measurement R Gallagher M Walker Karen O Dea K The in uence of a breakfast meal on the assessment of body composition using bioelectrical impedance European journal of clinical nutrition 52...

Страница 11: ...clean soft cloth Avoid rough sticky cloth to prevent scratching the measurement platform and screen panels The FSC 330 does not contain user maintained parts Service and maintenance not described in t...

Страница 12: ...11 The product is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for...

Страница 13: ...istic of a typical location in a typical commercial or hospital environment Power frequency 50 60 Hz magnetic eld IEC 61000 4 8 30 A m 30 A m NOTE UT is the a c mains voltage prior to application of t...

Страница 14: ...the frequency of the transmitter where p is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE1 At 80 MHz and 800 MHz the separation distance...

Отзывы: