background image

 

37

OSBURN LIMITED LIFETIME WARRANTY 

 

The  warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This warranty covers brand 
new products only, which have not been altered, modified nor repaired since shipment from factory. Proof of purchase (dated bill of 
sale), model name and serial number must be supplied when making any warranty claim to your OSBURN dealer.   

This warranty applies to normal residential use only.  Damages caused by misuse, abuse, improper installation, lack of 
maintenance, negligence or accident during transportation are not covered by this warranty. 

This warranty does not cover any scratch, corrosion, warping, or discoloration caused by over firing, abrasives or chemical cleaners. 
Any defect or damage caused by the use of unauthorized parts or others than original parts void this warranty. An authorized qualified 
technician must perform the installation in accordance with the instructions supplied with this product and all local and national 
building codes. Any service call related to an improper installation is not covered by this warranty. 
The manufacturer may require that defective products be returned or that digital pictures be provided to support the claim. Returned 
products are to be shipped prepaid to the manufacturer for investigation. If a product is found to be defective, the manufacturer will 
repair or replace such defect and reasonable transportation fees will be refunded. Repair work covered by the warranty, executed at the 
purchaser’s domicile by an authorized qualified technician requires the prior approval of  the manufacturer. Labour cost and repair 
work to the account of the manufacturer are based on predetermined rate schedule and must not exceed the wholesale price of the 
replacement part. All labour and  freight costs covered by this warranty are  limited according to the table below.   
The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect. The 
manufacturer may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of 
any warranted but defective parts The manufacturer shall in no event be responsible for any special, indirect, consequential damages 
of any nature, which are in excess of the original purchase price of the product.

 

 

WARRANTY APPLICATION 

DESCRIPTION 

PARTS LABOUR 

Combustion chamber (welds only), heat exchanger,  and castings.  

Lifetime 

5 years 

Plating (defective manufacture) – subject to limitations above 

Lifetime 

n/a 

Burner 

5 years 

3 years 

Stainless steel baffle and parts 

5 years 

3 years 

Carbon steel baffle and parts 

2 years 

1 year 

Ceramic logs, masonry-like panels, and ceramic glass (thermal breakage 
only*) 

2 years 

n/a 

Gas valve, pilot assembly & related parts, blowers, switches, rheostat, and 
other controls.   

1 year 

1 year 

Paint (peeling) and gaskets 

1 year 

n/a 

*Pictures required 

 

Shall your unit or a components be defective, contact immediately your OSBURN  dealer. Prior to your call make sure you have the 
following information necessary to your warranty claim treatment: 
 

• 

Your name, address and telephone number;  

• 

Bill of sale and dealer’s name; 

• 

Serial number and model name as indicated on 
the nameplate fixed to the back of your unit; 

• 

Nature of the defect and any relevant 
information. 

 

Before shipping your unit or defective component to our plant, you must obtain from your OSBURN dealer an Authorization 

Number. Any merchandise shipped to our plant without authorization will be refused automatically and returned to sender. 

 

Содержание SATURNA

Страница 1: ...vicinity of this or any other appliance What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas...

Страница 2: ...N 11 3 3 3 THERMOSTAT OR WALL SWITCH INSTALLATION 11 3 3 4 VENT INSTALLATION 14 3 3 5 FACEPLATE INSTALLATION 19 3 3 6 FIRE BOX COMPONENTS INSTALLATION 21 3 3 6 3 DECORATIVE DOORS INSTALLATION 23 3 3 7...

Страница 3: ...l 13 3 w c 3 3 kPa GAS INLET SUPPLY PRESSURE Maximum 13 5 w c 3 4 kPa Maximum 13 5 w c 3 4 kPa ORIFICE SIZE 0 4500 36 DMS 120 3 05mm 50 DMS 070 1 78mm AIR SHUTTER OPENING CLOSED 25 to 50 OPEN CONTROL...

Страница 4: ...codes with the National Electric Code ANSI NFPA No 70 1990 in the U S or with the current CSA C22 1 Canadian Electrical Code in Canada In the state of Massachusetts this product can only be installed...

Страница 5: ...onry fireplace must meet the minimum building code requirements or the equivalent for a safe installation Factory built fireplaces and their chimneys must be certified and meet local code requirements...

Страница 6: ...CAUTION Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or contact with hot surfaces Young children should be carefully supervised...

Страница 7: ...7 2 2 Lighting instructions...

Страница 8: ...tions before starting installation and follow them carefully during installation to ensure maximum benefit and safety Failure to follow these instructions will void your warranty and may present a fir...

Страница 9: ...the vent system the gas piping and the fan wiring Combustible surfaces such as the hearth mantle and facing must also be planned for NOTE All Installations Require Venting 3 3 1 Minimum clearances to...

Страница 10: ...IDE WALL COMBUSTIBLE TOP MANTLE COMBUSTIBLE SHELF FLOOR PROTECTION COMBUSTIBLE SIDE MANTLE E H Figure 7a Figure 7b A Combustible side wall to unit B Combustible side mantle to unit C Combustible top m...

Страница 11: ...ssure tap located on the front of the control valve Figure 3 WARNING Do not use an open flame to test for gas leaks 3 3 3 Thermostat or wall switch installation The burner control switch is located on...

Страница 12: ...14 1 6 100 30 5 TABLE 2 2 Solder an appropriate wire connector to each wire To connect to the burner switch 1 4 female quick connects are required and to connect directly to the valve use spade tongue...

Страница 13: ...13 INLET P IL O T TH OFF ON LO HI TP TH TP OUTLET THERMOPILE Figure 8a INLET OFF ON P IL O T TP TH LO HI TP TH OUTLET THERMOPILE Figure 8b...

Страница 14: ...ing this appliance into large fireplace cavities the vents may be connected directly to their attachments with the appliance in place Smaller cavities may require detaching the flue collar plate so th...

Страница 15: ...flashing onto the existing chimney c Attach the liners to the two 3 outlets on the approved Chimney Liner Termination Kit by first liberally applying High Temperature Sealant to the gasketed joint an...

Страница 16: ...16 3 LINER COUPLER ADAPTERS OPTIONAL INTAKE VENT EXHAUST 3 LINER FLASHING HIGH WIND CAP ADAPTER ADAPTERS OPTIONAL EXHAUST INTAKE VENT 3 LINER FLASHING ADAPTER HIGH WIND CAP Figure 10...

Страница 17: ...17 Figure 11...

Страница 18: ...406 508mm above the hearth d Push the insert back into the enclosure feeding the positioning strap through the slot at the top rear of the air jacket Ensure that the strap passes freely under the air...

Страница 19: ...ing one 1 screw each side Figure 14 5 Attach the left and right brass trim sides to the top trim with the corner brackets supplied Figure 15a 6 Slip the assembled trim over the faceplate and push the...

Страница 20: ...20 Figure 15a Figure 15b Figure 16 Figure 17...

Страница 21: ...1 3 3 6 Fire box components installation 3 3 6 1 Installing logs Step 1 Place the rear log on the pins located on the burner tray Step 2 Place the front right log on the pins located on the burner tra...

Страница 22: ...g Logs continued Step 3 Place the left front log on the pins located on the burner tray Step 4 Place the top Y log on the rear and front right log using the fixation pins located on the back and front...

Страница 23: ...me then attached the two 2 hook clamps located on the front underside of the firebox to the bottom door hinges Removal is reverse order Warning Do not operate the appliance with the glass front remove...

Страница 24: ...e off some odor It is important to ventilate the house during these initial burns We advise removing young children elderly persons and anyone suffering from breathing disorders or are sensitive to ox...

Страница 25: ...proper operation the pilot and main burner flames must be steady and not lifting off or floating The top 3 8 1 2 10 13mm of the thermopile should be engulfed by the pilot flame The pilot flame adjustm...

Страница 26: ...in access to the air shutter lever open the decorative front doors the lever passes through the control panel cover Pushing the lever to the rear increases aeration which will cause the flames to appe...

Страница 27: ...gure 22 To adjust damper 1 Open the decorative doors 2 Loosen but do not remove actuator lock screw 3 3 Pull or push the actuator to the required setting for your vent length see Table 3 4 Tighten act...

Страница 28: ...he USA derate the heater from sea level according to the gas installation code Altitude adjustment by changing the burner orifice Natural Gas ALTITUDE up to ft REDUCTION ORIFICE SIZE DMS TARGET INPUT...

Страница 29: ...cooled to room temperature Open the door remove the logs remove the 2 burner mounting screws one on the left and one on the right and lift the burner out of the unit When re installing the burner mak...

Страница 30: ...it up and towards you then out of the firebox 6 Remove the pilot hood by pulling it straight up and then unscrew the pilot orifice using an Allen key Screw in the new orifice and replace the pilot ho...

Страница 31: ...Safety screens removed for service must be replaced prior to operating the heater Annual service An annual service call should take between 1 2 hours Start by disassembling the unit take off the glas...

Страница 32: ...flame pattern with the figures in Section 3 3 6 For re lighting refer to the lighting instructions in Section 2 2 4 6 Fan replacement electrical schematic Caution Label all wires prior to disconnectio...

Страница 33: ...33 Figure 24 GROUND ON OFF SWITCH AND SPEED CONTROL THERMODISC BLOWER WHITE NEUTRAL BLACK HOT GREEN GROUND Figure 25...

Страница 34: ...nect all gas lines 5 Low pressure may be caused by bent line 5 Check for a kinked line 6 Valve control knob not fully depressed in PILOT position 6 Fully depress control knob II Pilot will not stay li...

Страница 35: ...ge is still insufficient replace thermopile 9 Wall switch thermostat or wires are defective 9 Follow previous corrective action check switch and wiring Replace where defective 10 Defective spill switc...

Страница 36: ...The following information s will be asked for the model name Saturna the type of gas used serial number and proof of purchase The damaged parts must be replaced by Osburn genuine parts You can consul...

Страница 37: ...are based on predetermined rate schedule and must not exceed the wholesale price of the replacement part All labour and freight costs covered by this warranty are limited according to the table below...