OSAKA- CI 49 Operating instructions. PAGE 1
CI 49
MICROPROCESSOR-BASED
DIGITAL ELECTRONIC
PULSE COUNTER
OPERATING INSTRUCTIONS
PREVIOUS STATEMENT
In this manual are contained all the necessary information for a
correct installation and the instructions for the use and the
maintenance of the product; we recommend, therefore, to read
carefully the following instructions.
The maximum care has been used in the realisation of this
document, anyway OSAKA does not assume any responsibility
deriving from the use of itself.
The same consideration has to be done for each person or
Company involved in the creation of this manual.
The herewith issue is an exclusive property of OSAKA which
forbids any reproduction and divulgation, although partial, if not
expressly authorised.
OSAKA reserves the right to execute aesthetically and
functional modifications, at any moment and without any notice.
INDEX
1
INSTRUMENT DESCRIPTION
1.1
GENERAL DESCRIPTION
1.2
FRONT PANEL DESCRIPTION
2
PROGRAMMING
2.1
SET POINT PROGRAMMING
2.2
PARAMETERS PROGRAMMING
2.3
PARAMETERS LOCK
3
INSTALLATION AND USE ADVICES
3.1
USE ALLOWED
3.2
MECHANICAL MOUNTING
3.3
ELECTRICAL CONNECTIONS
3.4
ELECTRICAL CONNECTION DRAWING
4
OPERATING MODE
4.1
COMMANDS OPERATING MODE
4.2
DISPLAY OPERATING MODE
4.3
OUT 1 OPERATING MODE
4.4
OUT 2 OPERATING MODE
5
PROGRAMMABLE PARAMETERS
5.1
PARAMETERS TABLE
5.2
PARAMETERS DESCRIPTION
6
TROUBLES, MAINTENANCE, WARRANTY
6.1
CLEANING
6.2
WARRANTY AND REPAIRS
7
TECHNICAL DATA
7.1
ELECTRICAL DATA
7.2
MECHANICAL DATA
7.3
MECHANICAL DIMENSIONS, PANEL CUT OUT AND
FIXING DEVICE
7.4
FUNCTIONAL DATA
7.5
INSTRUMENT CODE
1 - INSTRUMENT DESCRIPTION
1.1 – GENERAL DESCRIPTION
CI 49 is a programmable microprocessor based counter with
1or 2 outputs. The instrument offers the possibility to program:
up to 2 set points, 3 operating modes for the output OUT1, 4
operating modes for the output OUT2, 2 counting mode (UP or
DOWN) and offers the possibility of counting division. The
counting state is visualised on 4 digits display while the outputs
state is signalised by 2 led. The instrument can have 2 outputs
(relay or to drive solid state relays) and 2 digital inputs, one for
counting (CNT) and one programmable as RESET or reverse
counting. The digital inputs signals can be for free voltage
contacts or voltage signals (the same voltage supply value).
The programming of the instrument is possible by means of the
3 keys placed on the front where is also a reset key (F)..
1.2 - FRONT PANEL DESCRIPTION
1 - Key Set
: Used for the set point setting and to program the
functioning parameters
2 - Key DOWN
: Used to decrease the values or to select
parameters
3 - Key UP
: Used to increase the values or to select
parameters
4 - Key F
: Used to reset the count
5 - Led OUT 1
: It indicates when the output OUT1 is on or off.
6 - Led OUT 2
: It indicates when the output OUT2 is on or off.
7 - Led SET/CNT
: Signalize the set point or the parameters
programming mode (flashing fast), the count on (on) or reset
mode (off).
2 - PROGRAMMING
2.1 - SET POINTS PROGRAMMING
The instrument permits to program up to 2 sets:
“C1”
and
“C2”.
To program this sets do proceed as follows :
Pushing Key Set and keeping it pushed for 1 sec. approx., the
display will visualize
“C1”
and led SET/CNT will blink rapidly.
Releasing the key, on the display will be visualized the
programmed Set Point “C1”.
To modify it, work on keys UP, to increase the value or on key
DOWN, to decrease it.
If the OUT2 programmed functioning mode require the set “C2”
(F2 = 3 or 4), for programming this pressing Key Set again and
the display will show
“C2”.
Releasing the key, on the display will be visualized the
programmed Set Point “C2” and will be possible to modify it by
the key UP or DOWN.