2

 

Disassembly for storage of Light Unit 
 
1. 

Unplug Power Supply

.  

2.  Locate the four (4) Pry Slots at the joint between the DNL Can and the DNL Cap. 
3.  Using a Standard “Flat-Head” screwdriver, carefully separate the unit apart. 
4.  Unscrew the reflector assembly from the back of the light body. 
5. 

Leaving the DNL Cap assembly attached to the poolside

, carefully coil up the 25’ 

of cord and disconnect the power supply from its mounted location.  Lifting up and 
slightly pulling forward on the power supply box does this.  

6.  Store in box.  (Step 11) 
 
Reinstallation of Light Unit 
 
1.  Follow the installation steps 4, 5, 6, 7, 9, 10, and 11. 
 
Lamp Installation 
 
1.  Unplug Light unit from power source. 
2.  Locate the four (4) Pry Slots at the joint between the DNL Can and the DNL Cap 
3.  Using a Standard “Flat-Head” screwdriver, carefully separate the unit apart 
 
*

At this point, you have exposed a 12 volt 20 watt halogen bulb.  The bulb is 

attached to the socket by two male prongs extending from the bulb that connect 
to two female ports on the socket. 
 

4.  Pull gently on the bulb to remove it. 
5.  Take new bulb and insert it into the socket. The tabs are universal.  So there is no 

right or wrong way of inserting the bulb into the socket.  Push male end tabs, on 
bulb, into the female ports on the socket. 

6.  Take the DNL Can and push it back onto the DNL Cap.  Arrange the DNL Can so 

that the cord hangs down perpendicular to the ground. 

7.  Plug the Light unit back into the power source 
 

 
Important Safety Instructions 

 

1.  Light fixture is not intended as a step.  Using it as a step may cause injury to 

persons or damage to equipment.  

2.  Warning – Risk of electrical shock.  Connect only to a grounded type 

receptacle protected by a Ground Fault Circuit Interrupter (GFCI). 

3.  For a unit that does not have an integral GFCI, contact a qualified electrician if 

in doubt about whether or not a receptacle is protected by a GFCI 

4.  An extension cord should not be used. 
5.  The pool manufacturer determines the maximum water depth of lighting 

fixture. 

6.  Do not install on Therapeutic Pools, Hydro massage Bathtubs, Spas, or Hot 

tubs.  

 
 

 

Содержание PoolStar 3000

Страница 1: ...pool of the body Hand tighten firmly Fill pool with water to check for sufficient seal before proceeding The combination you should now have is Body Gasket Pool side Liner Gasket and DNL Cap 4 The DNL Can has a Ceramic Socket with a 12 volt Light Cord and a halogen reflector already installed Take the DNL Can and install bulb The pins on the bulb are universal There is no right or wrong way of ins...

Страница 2: ...bulb is attached to the socket by two male prongs extending from the bulb that connect to two female ports on the socket 4 Pull gently on the bulb to remove it 5 Take new bulb and insert it into the socket The tabs are universal So there is no right or wrong way of inserting the bulb into the socket Push male end tabs on bulb into the female ports on the socket 6 Take the DNL Can and push it back ...

Страница 3: ...h the mounting tab of the Power Supply and around the bail carriage handle 3 Insert the male end of the zip tie into the locking buckle Pull the male end through the buckle to form a large loop You will have approximately 1 of tie exposed Do not cinch the zip tie completely down 4 Repeat steps 1 through 3 for second zip tie installation The PoolStar 3000 is to be installed according to the manufac...

Страница 4: ...olStar 3000 Instructions for the Through The Wall Above Ground Pool Light 4 FOR EVERY ABOVE GROUND POOL THERE IS LIGHT ETL LISTED ONE YEAR WARRANTY EASILY CUSTOMIZABLE LOW COST EASY TO INSTALL LOW VOLTAGE ...

Отзывы: