4.2. Binding
A new relay must be bound to the control panel in order to successfully transmit commands
from receiver.
To register a relay, do the following:
1. In the control panel configuration, pre-set the required number of radiozones, their type,
group membership and other parameters;
2. Turn on the control panel in the operating mode and switch to the desired control
panel’s group;
3. Switch the control panel to the wireless relays binding mode (see the corresponding
control panel programming manual);
4. Connect power cable from mains to the relay (use the
IN
terminal block);
5. Switch the relay to the binding mode by short-circuit the
RESET
contacts for 2…3 sec-
onds (until the blinking green – the signal "
Binding
");
6. Binding will processed automatically and, if successful, ends by turning on the red LED
for 2…3 seconds (signal "
Bound
").
The relay waits 100 seconds for binding. To reinitialize the binding process, briefly close the
RESET
contacts again.
4.3. Schematic diagram
Relays should be connected in strict accordance with Figure 2.
Figure 2: Relay connection diagram
Relay-R
Version en_2