1.2 Using the Lightburn software
1.2.1 Grbl parameters related to flame and vibration detection:
$260: Flame detection count threshold, higher to reduce sensitivity, lower to increase sensitivity,
used with $261;The default value is 15.
$261: Fire test count trigger alarm threshold, higher to reduce sensitivity, lower to increase
sensitivity, use with $260;When 0, the flame detection function is off;The default value is 250.
$262: trigger threshold of vibration detection count, which can be adjusted to reduce the
sensitivity and lowered to improve the sensitivity;When the value is greater than 1000, the
function becomes invalid.
Enter $xx=value on the command line and press enter. The console returns OK.Xx indicates the
parameter number. Value indicates the value to be set. For example, to disable flame detection,
"$261=0".
Содержание OLM2 PRO S2