OLM2 PRO S2 vibration detection and flame detection
sensitivity setting instructions
Note: This document applies only to OLM2 PRO S2 models
1. Vibration detection & flame detection sensitivity adjustment and closure
1.1 Operate on laserGrbl software
1.1.1 Connecting the Device using laserGrbl
1.1.2 On the software menu bar, click Grbl and then click Grbl Configuration to enter the Grbl
parameter Configuration page
1.1.3 Grbl parameters related to flame and vibration detection:
$260: Flame detection count threshold, higher to reduce sensitivity, lower to increase sensitivity,
used with $261;The default value is 15.
$261: Fire test count trigger alarm threshold, higher to reduce sensitivity, lower to increase
sensitivity, use with $260;When 0, the flame detection function is off;The default value is 250.
$262: trigger threshold of vibration detection count, which can be adjusted to reduce the
sensitivity and lowered to improve the sensitivity;When the value is greater than 1000, the
function becomes invalid.
Click the value in the "Value" column. After changing the value, click the "Write" button to make
the setting take effect