background image

Instruction Manual

1-888-543-6473
1-888-541-6474

13376 Comber Way 

Surrey BC V3W 5V9

[email protected] 
www.ortechindustries.com

375 Admiral Blvd

 

Missis

s

auga

ON L5T 2N1

LED Security Light

 Sensors

MODEL

 OL-

CAUTION

INSTALLATION GUIDE

1. Turn OFF all power by removing fuse or flipping circuit breaker to OFF position
2. Screw motion sensor arm into the desired hole on junction box's cover plate.

Ensure that the sensor is positioned as shown with the LEDs on top.

3. Connect wires. Connect WHITE wires together using wire nuts provided. Connect BLACK

house wire to BLACK wire from sensor. Connect the RED wire from the sensor to the
BLACK wire(s) from the light fixture(s) using the wire nut provided. Tighten securely.
Carefully push all of the wires into the junction box. (See the diagram on the left)

NEUTRAL = White          LIVE = Black          RED = Load

DO NOT MOUNT ON THE GROUND. Recommended installation height is 6-1/2ft to 10ft/

This product is intended for use with enclosed gasket and with a junction box marked for 

use in wet locations. Before you begin, make sure that your power is turned OFF at your 

circuit breaker box. DO NOT rely on the switch power being turned OFF.

1. Install the cross bar to the junction box and secure with the (2) mounting screws. If installing to a wall or building, pre-drill holes and use

appropriate plugs / anchors. Once your holes are drilled, you can install the cross bar to the surface using the two mounting screws

2. On the cross bar locate GND, attach the ground wire with the grounding screw to the cross bar
3. Use a wire nut to connect the ground wire to the house ground wire (typically copper).

For proper connection, place wire nut over wires and twist clockwise until tight

4. Connect supply wires with wire nuts. BLACK supply wire connects to the BLACK power supply wire (Live).

WHITE product wire connects to the WHITE supply wire (Neutral)

5. You may use the optional gasket at this time round
6. Install the light fixture to the cross bar. Use silicon sealant (not included) around the perimeter of the light to seal for moisture
7. Screw in the stainless steel screw to hold fixture in place. Insert plastic screw cover into screw hole
8. Turn ON your electricity after the installation has been completed
9. Turn ON power switch. (if power is NOT ON, the light will NOT cycle ON or OFF)

Adjusting Your Motion Sensor

Your sensor head can be adjusted by turning the individual 

light head to detection area. 

You can also adjust your sensor head up and down to your detection distance.

REMINDER: If fixture is mounted higher 

than 

ft (2.4m),

 

aiming the sensor 

down will reduce coverage distance. 

The detector is less sensitive to motion 

directly towards it.

Rotate joint for

left and right 

directions (180°)

Rotate joint for 

left and right 

direction (180°)

Installation

For easy installation, select tan existing light operated by a wall switch for replacement.

 For best performance, mount the fixture about 8 ft (2.4m) above the ground. 

If fixture is mounted higher than 8 ft (2.4m), aiming the sensor down will reduce coverage distance. 

Setting the Motion Sensor

Detection Range: 70 ft

Detection Angle: 240°

CAUTION 

KEEP THE SENSOR AT LEAST 

2" (51 mm) AWAY FROM 

THE LAMPS.

Содержание OL-S

Страница 1: ... or high ambient temperatures 7 The security light CANNOT be used with a dimmer switch motion or occupancy sensor or other electronic switching device 8 This product is intended to be connected to a properly installed and grounded UL listed junction box WARNING RISK OF ELECTRICAL SHOCK Turn OFF electrical power at fuse or circuit breaker box before wiring product to the power supply Verify if the ...

Страница 2: ...und wire with the grounding screw to the cross bar 3 Use a wire nut to connect the ground wire to the house ground wire typically copper For proper connection place wire nut over wires and twist clockwise until tight 4 Connect supply wires with wire nuts BLACK supply wire connects to the BLACK power supply wire Live WHITE product wire connects to the WHITE supply wire Neutral 5 You may use the opt...

Страница 3: ...o come ON when it is darker outside slide the switch to Night To adjust the light to come on at dust slide the switch to Dusk To adjust the light to come on when it is lighter outside slide the switch to the Day SENS Setting The SENS slide switch knob control Set the slide switch knob to the Min position The sensor is low sensitivity setting Set the slide switch knob to the Mid position The sensor...

Страница 4: ...oo high reduce range setting Lights come on in daylight 1 Light control may be installed in a relatively dark location Lights stay ON continuously 1 A lamp is positioned too close to the sensor or pointed at nearby objects that cause heat to trigger the sensor reposition the lamp away from the sensor or nearby objects 2 Light control is pointed toward a heat source like an air vent dryer vent or b...