background image

Instruction Manual

1-888-543-6473
1-888-541-6474

13376 Comber Way 

Surrey BC V3W 5V9

[email protected] 
www.ortechindustries.com

375 Admiral Blvd

 

Missis

s

auga

ON L5T 2N1

Adjusting Your Light Heads

LED 

Security Lights

MODEL

 

OL-

2

H

S

CAUTION

INSTALLATION GUIDE

Your light heads can be adjusted by turning the individual light head to desired position. 
You can also adjust your light head up and down to your desired position.

WARNING

Risk of fire. DO NOT aim the bulbs at a combustible surface within 3 ft (1m).

Adjusting Your Motion Sensor

Your sensor head can be adjusted by turning the individual 

light head to detection area. 

You can also adjust your sensor head up and down to your detection distance.

Sensor head adjust 

Pan:

 left 170° / right 170°

Tilt:

 up 0° / down 60°

REMINDER: If fixture is mounted higher 

than 

ft (2.4m),

 

aiming the sensor 

down will reduce coverage distance. 

The detector is less sensitive to motion 

directly towards it.

Installation

For easy installation, select an existing light operated by a wall switch for replacement.
For better performance, mount the fixture about 8 ft (2.4m) above the ground.
If the fixture is mounted higher than 8 ft (2.4m), aiming the sensor down will reduce coverage distance.

Setting the Motion Sensor

Detection Range:

 50'

Detection Angle:

 180°

CAUTION

Keep the sensor at least 

2" (51 mm) away from 

the lamps.

Sensor Detection Range

Night Dusk Day

5s

1 5 12 min

Содержание OL-2HS

Страница 1: ...TRICAL SHOCK Turn OFF electrical power at fuse or circuit breaker box before wiring product to the power supply Verify if the supply voltage is correct before installing 110V 240V Make all electrical and grounded connections in accordance with the National Electric Code and any applicable local code requirements All wiring connections should be capped with UL listed wire connectors WARNING RISK OF...

Страница 2: ...ross bar locate GND attach the GROUND wire G with the grounding screw F to the cross bar 4 Use a wire nut H to connect the grounding wire G to the house ground wire typically copper For proper connection place wire nut over wires and twist clockwise until tight 5 Connect supply wires with wire nuts H as shown in the figure on the bottom left BLACK supply wire connects to BLACK power supply wire Li...

Страница 3: ...dual light head to detection area You can also adjust your sensor head up and down to your detection distance Sensor head adjust Pan left 170 right 170 Tilt up 0 down 60 REMINDER If fixture is mounted higher than 8 ft 2 4m aiming the sensor down will reduce coverage distance The detector is less sensitive to motion directly towards it Installation For easy installation select an existing light ope...

Страница 4: ... objects reflecting light may trigger the shut off feature DO NOT point other lights at the sensor REMINDER Sensor has a 1 1 2 minute warm up period before it will detect motion When first turned ON wait for 1 1 2 minute TROUBLESHOOTING Lights will not come on 1 Light switch is turned OFF 2 Light is loose or burned out 3 Fuse is blown or circuit breaker is turned OFF 4 Daylight turnoff is in effec...