background image

vi

Содержание 9306

Страница 1: ...Model 9306 1 GHz Preamplifier Operating and Service Manual Printed in U S A ORTEC Part No 761700 1202 Manual Revision F ...

Страница 2: ...rn so that a Return Authorization Number can be assigned to the unit Also ORTEC must be informed either in writing by telephone 865 482 4411 or by facsimile transmission 865 483 2133 of the nature of the fault of the instrument being returned and of the model serial and revision Rev on rear panel numbers Failure to do so may cause unnecessary delays in getting the unit repaired The ORTEC standard ...

Страница 3: ...RUCTIONS AND SYMBOLS iv SAFETY WARNINGS AND CLEANING INSTRUCTIONS v 1 DESCRIPTION 1 2 SPECIFICATIONS 1 2 1 PERFORMANCE 1 2 2 INPUTS AND OUTPUTS 1 2 3 ELECTRICAL AND MECHANICAL 1 2 4 WEIGHT 2 3 INSTALLATION AND OPERATION 2 4 MAINTENANCE 2 ...

Страница 4: ...s a hazard that could result in bodily harm if the safety instruction is not observed CAUTION Indicates a hazard that could result in property damage if the safety instruction is not observed Please read all safety instructions carefully and make sure you understand them fully before attempting to use this product In addition the following symbol may appear on the product ATTENTION Refer to Manual...

Страница 5: ...the instrument during external cleaning use only enough liquid to dampen the cloth or applicator SAFETY WARNINGS AND CLEANING INSTRUCTIONS Cleaning Instructions To clean the instrument exterior Unplug the instrument from the ac power supply Remove loose dust on the outside of the instrument with a lint free cloth Remove remaining dirt with a lint free cloth dampened in a general purpose detergent ...

Страница 6: ...vi ...

Страница 7: ...r power connector 2 SPECIFICATIONS 2 1 PERFORMANCE All specification are measured with a pulser having a pulse width of 2 ns FWHM and a rise time of 150 ps Where significant the measurement is corrected for the rise times of the pulser coaxial cable and oscilloscope The specifications are identical for OUTPUTS 1 and 2 GAIN Nominally 100 50 to 150 non inverting into a 50 ohm output load OUTPUT RISE...

Страница 8: ...to note that it is not possible to provide input over voltage protection at such high frequencies Therefore the magnitude of the input signal must be less than 1 V Excessive input voltages will damage the 9306 To utilize the high frequency performance of the 9306 careful signal handling is required The input and output cables for the 9306 should be short high quality 50 ohm cables since only a few...

Отзывы: