![ORPU Orcut TES 148 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/orpu/orcut-tes-148/orcut-tes-148_disassembly-assembly_1654299016.webp)
Assembly of cutting system with
end-face seal at TES 148
•
Tighten the fastening screws M6x20
•
By lifting the knife the cutting gap of
0,10-0,15 mm is adjusted
•
The knife is lifted by the studs M8x12
•
Tighten the fastening screws after adjustment
•
The adjustment must be carried out very
conscientiously
•
The cutting system is set well if a distance of
0.1-0.15 mm is set on all webs of the knife
•
Only a cutting system, which is set according
to the specifications, ensures a safe operation
16