Icon
Light
Meaning
OFF
No network detected
FAST
Network malfunction detected (e.g., no auto-negotiation)
ON
Network OK, configuration OK
OFF
Unit OK
FAST
Unit requires attention; check other status LEDs, see Web UI
HEARTBEAT
See table
"LED Lighting Patterns" on page 10
OFF
Temperature OK
FAST
High temperature detected
1.4.3.1
LED Patterns during Boot Sequence
For the first five seconds after power-up all LEDs will be OFF. Then the Power LED will be
blinking before it will be lit permanently. If you have configured your unit to operate in
Blackout Mode, this will take effect once the blinking cycle ends.
1.4.4
Blackout Mode
All LEDs can be turned off via the Web UI.
The LED brightness level can be set from
63
(as bright as possible) to
0
(not visable).
To disable all LED activity via the WebUI:
Navigate to
MANAGEMENT > OTHER: LED Configuration
, and set the Brightness
level to "0".
1.5
The VersaPNT Web UI
VersaPNT has an integrated web user interface (referred to as "Web UI" throughout this
documentation) that can be accessed from a computer over a network connection, using a
standard web browser. The Web UI is the most complete way to configure the unit, and for
status monitoring during everyday operation.
Note:
If you prefer, an integrated Command- Line Interpreter interface
(CLI) allows the use of a subset of commands.
12
VersaPNT Getting Started Guide Rev. 3.0
1.5 The VersaPNT Web UI