SNMP Status
pop-up window will display:
The following settings can be configured in this window:
In the
sysObjectID
field, enter the SNMP system object ID.
In the
sysContact
field, enter the e-mail information for the system contact
you wish to use.
In the
sysLocation
field, enter the system location of your VelaSync unit.
4.
Click
Submit
, or cancel by clicking the
X
-icon in the top-right corner.
Accessing the SNMP Support MIB Files
Spectracom’s private enterprise MIB files can be extracted via File Transfer Protocol (FTP)
from VelaSync, using an FTP client such as FileZilla or any other shareware/freeware FTP
program.
To obtain the MIB files from VelaSync via FTP/SFTP:
1.
Using an FTP program, log in as an administrator.
2.
Through the FTP program, locate the Spectracom MIB files in the
/home/spec-
tracom/mibs
directory.
3.
FTP the files to the desired location on your PC for later transfer to the SNMP Man-
ager.
4.
Compile the MIB files onto the SNMP Manager.