DANGER!
This product relies on the building's installation for short-circuit
(overcurrent) protection. Ensure that the protective device is rated not
greater than: 250 V, 20 A.
2.
Plug in power to both power supplies (items 13 & 14
)..
As soon as at least one of the two power supplies has been connected to the mains
voltage, you may hear
fan noise
from inside the VelaSync housing. However, note
that the unit is not running yet (check the front indicator lamps: they will remain
dark).
3.
Switch the unit on by pressing the ON/OFF button on the front panel. Wait for the
device to boot up.
Note:
If only one power supply is running, and the other one is inser-
ted all the way, but not plugged in, or defective, VelaSync will emit a
long BEEP, so as to alert you of a problem with the backup power.
Figure 2-5:
ON/OFF button
4.
Once the boot process is completed, only the green POWER status LED should be
lit.
30
CHAPTER
2
•
VelaSync 1232 User Manual Rev. 4
2.5 Basic Connections Setup
Содержание Spectracom VelaSync 1232
Страница 2: ......
Страница 4: ...Blank page II VelaSync 1232 User Manual...
Страница 12: ...BLANK PAGE X VelaSync 1232 User Manual TABLE OF CONTENTS...
Страница 28: ...16 CHAPTER 1 VelaSync 1232 User Manual Rev 4 1 7 The VelaSync Web UI...
Страница 34: ...BLANK PAGE 1 9 Regulatory Compliance 22 CHAPTER 1 VelaSync 1232 User Manual Rev 4...
Страница 264: ...BLANK PAGE 252 VelaSync 1232 User Manual...