Orolia kannad aviation RC100 Скачать руководство пользователя страница 2

25-63-20

© Orolia S.A.S.

Abbreviated Component Maintenance Manual

S1820513-03 / S1820513-07

 Page 

2

FEB 03/2014

3

A red LED.

4

An adhesive label (production marking) bonded on the cable bundle near the switch. It
gives this information:

-

Part Number, P/N.

-

Amendment, AMDT.

-

Serial Number, S/N.

-

Number of evolution since the production release (1, 2, 3, 4).

-

Control status (V, D, C, CF).

(b)

The RC100 / RC150 name plate is bonded on the rear of the switch. It gives this information:

1

Manufacturer code

2

P/N

3

Pin assignment (1, 2, 3).

B.

Technical Data

(1)

Overall Dimensions: 

Refer to Figure 2 / 25-63-20-991-02-1 Overall Dimensions

Figure 2  / 25-63-20-991-02-1

Overall Dimensions

(2)

Weight: 13 g. (0.0286 lbs).

(3)

Environmental Characteristics

-

Operating temperature: -20 Degrees Celsius to +55 Degrees Celsius.

-

Storage temperature: -55 Degrees Celsius to +85 Degrees Celsius.

-

Magnetic effects: DO 160C / ED14C Category Z.

-

Induced signal susceptibility: DO 160C / ED14C Category Z.

-

Radio frequency signal susceptibility: in compliance with ED 62 § 4.4.10.

Note: all dimensions are in millimeters
          (inches in brackets).

30 (1.18)

35 (1.378)

26 (1.028)

44 (1.732)

The document reference is online, please check the correspondence between the online documentation and the printed version.

Содержание kannad aviation RC100

Страница 1: ...line cabin installations or cockpit retrofit b The RC150 is a variant of the RC100 This version has a more rugged toggle switch c The RC100 and RC150 permit remote control of the primary functions of...

Страница 2: ...echnical Data 1 Overall Dimensions Refer to Figure 2 25 63 20 991 02 1 Overall Dimensions Figure 2 25 63 20 991 02 1 Overall Dimensions 2 Weight 13 g 0 0286 lbs 3 Environmental Characteristics Operati...

Страница 3: ...f activated before or to do a self test b Monitoring is done through a red LED 2 Hz pulsed signal during ELT transmission on 121 5 and 243 MHz One long flash during ELT transmission on 406 MHz at 50 s...

Страница 4: ...ch to RESET TEST position c Make sure that the resistance between pins G and A is between 7125 Ohms and 7875 Ohms 4 Energize the LED with the 9V battery through a 470 Ohms resistor to pin J to pin G M...

Страница 5: ...4 CLEANING 5 CHECK 6 REPAIR 7 ASSEMBLY B Consumables NOTE You can use alternative consumable from other suppliers if the consumable has equivalent properties Table 9002 25 63 20 992 02 List of Consuma...

Страница 6: ...ASS 1 1A S1820513 03 KIT REMOTE CONTROL PANEL RC 100 RF 1B S1820513 07 KIT REMOTE CONTROL PANEL RC 150 RF 10A 0134162 SUPPORT NP 1 20A 0134146 LED RED NPNP 1 30A 0125759 SWITCH TOGGLE NPNP 1A 1 30B 0...

Страница 7: ...7 FEB 03 2014 Storage and Transportation TASK 25 63 20 500 801 A01 1 Storage and Transportation A General 1 Storage temperature 55 Degrees Celsius to 85 Degrees Celsius The document reference is onli...

Страница 8: ...ated Component Maintenance Manual S1820513 03 S1820513 07 Page 8 FEB 03 2014 PAGE INTENTIONALLY LEFT BLANK The document reference is online please check the correspondence between the online documenta...

Отзывы: