Low-voltage
Red LED Lighting, and the buzzer beep 0.5s every 5s
Over-voltage
Red LED Lighting, and the buzzer beep 0.5s every 1s, and shut down after
60s.
Invert Mode
Over-Load
110%< load<125%, no alarm in 14 minutes, beeps every 5s in 15th minute,
and shut down after 1 minutes.
125% <load<150%, beeps 0.5s every 1s , and shut down after 60s.
Load>150%, shut down after 20s.
Over Temperature
Cooling fin temp. ≥105ºC, Over temp red LED Lighting, every 1s beeps 0.5s ;
Protection
Over Temperature
Protection
Cooling fin temp. ≥105ºC, start to protect after 30 seconds(Shutdown Output)
Back-Feed
Protection
Yes(Automatic Restart)
The resumption of
work after fault
Mode of operation: restart the inverter