DESCRIPTION OF THE PRODUCT 

The device is designed to analyze energy used by electric appliances. It can be installed in an easy and fast way by connecting it 
between the socket and the power plug of the device you want to control. This power meter is suitable for use with standard power 
sockets only (230V AC). The maximum load of the socket cannot exceed 3680W. In order to forecast the cost, you need to enter a 
unitary price for electric energy (currency in EUR). This device cannot be calibrated thus it cannot be used as consumption costs 
calculator. It is not suitable for use in moist areas, nor in inadequate conditions.  
Inadequate conditions include: 

wet or increased humidity areas, 

dust, flammable gases, vapors, dissolvents, 

storm or other harsh weather conditions that can generate strong electrostatic field, etc. 

OPERATION AND USE 

RESET button: 
Before first use, make sure to reset the device with the RESET button.  
If the device does not respond when you press the buttons, make sure to reset it with the RESET button.  
Once  you  plug  in  the  meter,  all  icons  will  be  visible  on  the  LCD  display  for  about  1  second.  After  this  time,  the  device  will 
automatically shift to a working mode.  

 

DATA ON THE DISPLAY:

 

ENERGY - first line of the display shows power. 
In order to change the data on the display, press ENERGY button. The data are displayed in the following order:  
Power (W)→Voltage (V)→Current (A)→Frequency (Hz) →Power factor →Power (W) 
1. Power range

0.0 W

3680 W 

2. Voltage range

150 V AC

276 V AC 

3. Current range

0,000 A

16 A 

4. Frequency range

50 Hz

60 Hz 

5. Power factor range

0.00

1.00  

 
TOTAL – second line of the display shows total cost. 
In order to change the data on the display, press COST button. The data are displayed in the following order:  
Total  electric  energy  (kWh)→Total  electric  energy  cost  (€)→  Total  amount  of  generated  CO2  (Kg)→Total  time  in  days 
(Day)→Electric energy cost (€/kWh)→Total electric energy (kWh). 
 
1. Total electric energy range

0.000 kWh

9999 kWh

 

2. Total electric energy cost range

0.00 €

9999 €  

3. CO2 emission range

0.00-9999 kg 

4. Total time

0-9999 days 

5. Electric energy cost adjustment range: 00.00 €/kWh

99.99 €/kWh 

 
ON TIME – third line of the display shows total time.  
Data are displayed in 00:00 format, where two first digits express minutes (2 digits first appear after 10 minutes lapse) and the other 
two digits express seconds. When 60 minutes lapse, 00:00 will be again displayed, where two first digits express hours (2 digits first 
appear after 10 hours lapse) and the other two digits express minutes. After 24 hours, the time will be recalculated.  
NOTE: In real time status, all data are updated every second.  
 
ADJUSTING THE PRICE PER 1kWh: 
Press and hold SET for 3 seconds, in order to enter electric energy cost settings (in €/kWh). 
Press UP in order to change the values. 
Press SET in order to select next digit. 
Press COST in order to confirm the settings. 
 
** If you don’t press any button within 10 seconds, the device will automatically exit the settings mode.  
 
ENERGY OVERLOAD:
 
If you connect the socket with the load exceeding 3680W, ENERGY interface will flash on the display. 
 
In order to completely reset the device and to return to default settings, press RESET for a short while.  

TECHNICAL SPECIFICATION: 

Power source:  230VAC, 50 Hz

 

Max. current:  16A

 

Rated load:  3680W

 

Voltage range:  150VAC

276VAC

 

Total time range:  0 sec 

9999 days

 

Displayed price range:  00.00 €/kWh

99.99 €/kWh

 