NORLAND
13
5.4 BOILER COVERING model. 350 - 860 (Fig. 6)
•
Mount the panels (1D) fixing the lower folds on to the metal strut on the boiler and attaching the upper
ones to the centre with the appropriate screws. Repeat the same procedure for the panels (1S).
•
Mount the panels (2D) fixing the upper folds to the rectangular tube and inserting them into the appropri-
ate slits in the lower panels. Repeat the same procedure for the panels (2S) leaving the burner-control
panel connection cables sticking out from the existing opening
(for the wiring harness please refer to the
control panel diagram and to the standard plugs connection kit).
•
Unwind the thermostat capillaries, attach the control panel (3) to the side with a screw, then insert the
bulbs into the shaft.
•
Mount the upper panels (4P), (4D) and (4S) with screws and plug the holes with the caps.
•
Mount the panel (5); attach the support bracket (6) to the frame base, position the panel (7D) and then
the panel (7S) with fairlead attached to its side panels. Screw on tightly and plug the passage holes with
the appropriate caps.
•
Attach and screw on the front/central (8) and front/lower (9) panels.
•
Finally, screw the document holder (10) on to the opposite side of the control panel.
Fig. 6