IM0973120 A 01
3
UNITS IN MM
122,0
96,0
13,0
80,0
74,9
7,7
40,0
14,7
R4,5 +0,5 -0,0
∅
10,0
122,0
141,5
260,0
109,0
140,2
122,0
141,5
Installation Manual
1. Introduction
The Thermal Image Camera TIC gives in all weather, day or night, in fog
or smoke a clear picture of the situation.
The Camera TIC can be operated with the Orlaco Monitor 7" RLED/LEDD
and the Orlaco Monitor 12" RLED.
2. Mounting
A camera bracket is supplied with the Camera TIC Alu/Sst; the package
includes the necessary nuts, bolts and washers.
Use of a different type of bracket or bracket made by a different
manufacturer is not permitted.
This bracket is suitable for mounting the camera in hanging, standing and
overhead positions, see figure 1. Use a Allen key to adjust the bracket to
the camera with M6 socket head cap screws. Use a 13-mm open-ended
spanner to secure the camera bracket with four M8 bolts, nuts and wash-
ers. See figure 2.
3. Operation
3.1. Overpressure in the enclosure
The enclosure of the Camera TIC is with dry-nitrogen filled and has a 1,4
Bar overpressure, therefore IP68 according to IEC 60529 (25 m under
water).
3.2. Valve
WARNING:
Do not open the enclosure.
The enclosure is protected by static pressurisation (Nitrogen).
The enclosure shall be filled only by the manufacturer.
The filling valve, may
ONLY
be used by the manufacturer.
Do not remove
the blue seal.
See figure 3
A
.
The warranty expires when the blue seal
is broken!
The warranty expires when the user does not act according the
instructions.
If the pressure is lost send the device back to the manufacturer for inves-
tigation, repair and testing.
3.3. Switching on and off
The Camera TIC Alu/SSt is switched on by connecting the connector
cables to the power supply. It is switched off by disconnecting the Power
cable from the power supply. Under normal circumstances, the system
starts once the power is 24V/DC+/-10%.
Ensure that all parts are firmly fixed, stable and secure.
Figure 2
Figure 3
Figure 1
Filling valve
with blue seal
A
A
Bracket overhead
Bracket standing
Bracket hanging
Camera TIC Sst; Art. no. 0103740
M8
M6
1221300
5m cable
Attention:
Always use the
Isolation manchets
Camera TIC Sst
Art. no. 0103740
Содержание 0103732
Страница 10: ...10 IM0973120 A 01 Installation Manual ...