Power saving mode. 

 

The portable tester features a power saving mode: the backlight switches to screen-saver mode after 
15 minutes go by without a button being pressed (the values remain on display). Press any button to 
revert to full display mode. 
 
The  tester  shuts  down  automatically  if  two  hours  go  by  without  a  button  being  pressed.  Press  any 
button to exit standby mode: the three-minute countdown begins again. 

 

Important:

  If  the  values  displayed  on  the  screen  seem  stuck  or  if  the  tester  has  not  been  used  for 

quite some time, take the tester outdoors and leave it in a dry, protected place for 30 minutes to clear 
the sensors. 

 

Conditions of use and safety considerations:  

 

Use the indoor air quality tester only for its intended purpose.  
Do not alter the structure of the product or repair it yourself.  
Use only the cables and connectors supplied with the product.  
The manufacturer cannot be held liable for damages arising from improper use or maintenance of the 
product.  
Keep the appliance out of children’s reach. 

 

Troubleshooting guide: 

 

 

Fault symptoms 

Checks/solutions 

The tester does not turn on. 

Make sure the battery is charged. 

 

Make sure the charger is properly connected. 

 

Make  sure  the  USB  port  of  the  power  source 
(computer, mains adapter, etc.) is receiving current. 
Check whether the mains outlet socket has an on/off 
switch. If so, switch it on. 

 

Press  and  hold  in  button  (7)  until  the  screen  comes 
on. 

The alarm doesn’t go off. 

Make sure the alarm has not been cancelled. 

 

The visual alarm is set only for formaldehyde (HCHO) 
and  goes  off  when  the  user-set  threshold  is 
exceeded. 

The  stored  readings  interface  does  not  show 
any measurements. 
 

The  screen  should  display  the  last  ten  readings  of 
HCHO, 

PM2.5, 

temperature, 

and 

humidity 

measurements. 

 

Make sure this option has not been disabled. 

The tester display keeps switching off. 

The tester has a power saving mode. 

 

Press any button to exit power saving mode. 

 

Disable power saving mode in the settings (“Never”). 

 

Two  settings  affect  battery  charge  life:  the  screen 
backlight level and the power saver delay. 

Содержание 23660

Страница 1: ...s Measures concentrations of airborne pollutant formaldehyde HCHO particulates PM1 0 PM2 5 PM10 and total volatile organic compounds TVOC in a room and displays them on the LCD display Measures and di...

Страница 2: ...and adapt to the atmosphere A countdown of this time in seconds is shown on the TVOC display line 4 To recover from the effects of packaging and shipping the device must be placed outdoors in a dry p...

Страница 3: ...measured data points on the graphs select Clean Power saving mode Off Time to adjust the delay before the screen switches to standby mode Never or after 30 60 or 90 minutes If a set time is chosen the...

Страница 4: ...is switched on If no readings are displayed make sure the Clear Log option is not activated Clean Step 4 Measurements and comfort ratings 1 Particulates are airborne particles resulting from wood bur...

Страница 5: ...iod 2 Move away from the source of pollution Leave the room Ventilate 1 Guide values for Formaldehyde and Benzene based on French decree No 2015 1000 of the 17 August 2015 2012 14 Long exposure throug...

Страница 6: ...ach threshold is coupled to a specific exposure time If the measured values regularly exceed these limits a professional diagnosis is advisable to identify the source of the pollutants The AQI Air Qua...

Страница 7: ...held liable for damages arising from improper use or maintenance of the product Keep the appliance out of children s reach Troubleshooting guide Fault symptoms Checks solutions The tester does not tu...

Отзывы: