VII. Final Proof Characteristics 

All certified proofs must display the ORIS Digital Proof Control Strip. The control strip must be 
checked for color quality using the following expected color and image characteristics. 
 

 

 

Color Density 

TVI 

Print 

Contrast 

Color 

 

 

Dot Gain @ 50% 

@ 75% 

h(ab) 

 

( ± 0.05 ) 

( ± 3% ) 

( ± 5% ) 

( Delta E

*

 < 2.5 ) 

Cyan 

1.30 20.0% 32.0% 

54.81 

55.39 

228.50 

Magenta 

1.41 20.0% 36.0% 

46.65 

68.76 

357.83 

Yellow 

1.01 18.0% 26.0% 

84.89 

84.49 

94.13 

Black 

1.65 22.0% 39.0% 

17.54 

2.82 

65.05 

Red 

NA NA  NA 

46.11 

76.12 

34.05 

Green 

NA NA  NA 

51.07 

66.38 

155.73 

Blue 

NA NA  NA 

24.89 

46.87 

293.47 

Gray 25 

NA NA  NA 

71.42 

-1.01 

3.95 

Gray 50 

NA NA  NA 

52.59 

-1.02 

2.23 

Gray 75 

NA NA  NA 

38.33 

-2.11 

2.52 

 

Paper White Density Measurements 

(Tolerance ± 0.02)

 

Dc Dm Dy  Dk 

0.12 0.11 0.13 0.16 

Paper White CIE LCh(ab) Measurements 

(Delta E

*

 < 2.5)

 

 L C 

h(ab) 

 

89.26 5.44 87.82 

 

*

 Delta E represent values within material color difference measured at target density 

 

The above CIE LCh(ab) measurements were made using a calibrated GretagMacbeth Spectrolino with 
GretagMacbeth KeyWizard software. All CIELCh values are in accordance with CGATS.5 Standard on Colorimetric 
Calculations. 

 

The TVI values were calculated using the Murray-Davies equation, Print Contrast as absolute. All calculations are in 
accordance with the CGATS.4 Standard for densitometry. 

 

The above density measurements were made using a calibrated GretagMacbeth Spectrolino with GretagMacbeth 
KeyWizard software with absolute Status-T response, no filter, D50 illuminant and a 2

°

 observer and black backing. 

All density values are in accordance with CGATS. 4 Standard for densitometry.

 

 

VIII. Sample Proofs 

CGS Publishing Technologies International has submitted two sample proofs that confirm 
to this application data sheet specification. These have been submitted to the SWOP 
certification committee for their analysis. Copies of this document are on file with SWOP 
Inc., or can be downloaded via CGS’ web site: 

www.cgsusa.com

.

 