background image

22

23

pixels). You will get the best guiding performance when your image background 
looks smooth and black. 
The Gamma Adjustment will help clip the low level background noise by adjusting 
the slider bar left or right as needed. You can also reduce the camera Gain or 
enable Noise Reduction (see “Advanced Autoguider Settings”). 
Take Dark saves a dark frame which is subtracted from your guiding images 
to remove most of the noise. Dark frames are images taken with the camera 
capped from incoming light, revealing only the camera noise in the image. This 
noise is subtracted from a “light frame” which is the image you want to see from 
the camera.
To take the dark frame:
1.  Cap the objective of your guide scope.
2.  Keep the Exposure Selection set to the same time you wish to use for guid-

ing. For example, if you choose 2.0 s, then you must keep this exposure time 
while guiding for the dark frame to be effective. 

3.  Click Take Dark.
4.  Remove the cap from your guide scope and resume taking pictures or guid-

ing. PHD Guide will automatically subtract the dark frames from all of your 
exposures. To remove the dark frame, go to Tools and select Erase Dark 
Frame.

Advanced Autoguider Settings

The Advanced Parameters (the brain icon) in PHD allows you to change several 
settings to better customize the guiding performance of your SSAIO. Under nor-
mal use, you should not have to make any major adjustments to the Advanced 
Parameters. All of the calibration and autoguiding is done automatically simply 
by pressing the PHD Guide icon. However the following settings can be adjusted 
to cater to your specific guiding setup:

Advanced Parameters

R.A. Aggressiveness: Adjusts the percentage of R.A. correction per step. The 
default value is 100, meaning that the guider will move the full distance of the 
correction. If the seeing conditions are not steady, the aggressiveness can be 
turned down to smooth out the quick movements and reduce the correctional 
movement. 
R.A. Hysteresis: Implements a percentage of the previous averaged tracking 
corrections to the current tracking corrections. This setting can be useful if you 
are experiencing some wind or severe periodic error, since the guider will partially 
ignore some of the radical movements and repeat a percentage of the previous 
tracking corrections.

Dec Guide Mode: Allows Dec guiding to be turned on or off, or switched which 
side of drift to guide on, or auto which will find the side of drift (N/S).
Dec Algorithm: Settings that attempt to smooth the declination corrections to 
one consistent movement and can be used to resist switching directions in Dec.
Calibration Step: Adjusts how long each guide pulse is during calibration. The 
default is 500 milliseconds. The calibration step can be increased to provide a 
better sample of movement. However, if the calibration step is increased too 
much, the guide star will move out of the camera’s field of view during calibration.
Min. Motion: Number of pixels the star must move before PHD will make a guid-
ing correction. The default is 0.25 pixels.
Search Region: The area in pixels that the guide star is searched for and looked 
at. The default is 15x15 pixels. Under normal use, this setting should not be 
changed.
Noise Reduction: Choose from 2x2 mean or 3x3 median to smooth out noise 
and blur out hot pixels. 
Time Lapse: This setting optionally sets a delay between each guiding correc-
tion. For mounts that track exceptionally well, you can add a delay between each 
correction.
Gain: The gain adjusts the camera’s internal brightness level and sensitivity. The 
default is 95%. If you are experiencing excessive noise or hot pixels, you can 
reduce the gain. The camera remains very sensitive as low as 50% gain. If you 
are guiding on a very bright guide star, you can afford to turn down the gain and 
further decrease the noise in your image.
Force Calibration: Enabling this setting makes PHD Guide calibrate every time 
a new star is chosen. If you move your telescope to another object in the sky, 
you will need to recalibrate the autoguider. The default has this setting enabled.
Log Info: You can log all actions into a text file saved in the PHD directory.
Disable Guide Output: This setting deliberately shuts off the autoguider output 
for potential troubleshooting measures.

Autoguiding tips & tricks

If all conditions are ideal, and your tracking is superb, you typically do not have to 
alter any of the camera’s default settings. However, if your setup is tracking much 
worse than usual (such as a night with high wind or poor seeing), you may need 
to customize your settings to better adapt to the current conditions in the field.
Reduce the R.A. Aggressiveness in the Advanced Parameters menu to better 
stabilize the guiding during bad seeing or wind gusts. You may also want to 
decrease the R.A. Aggressiveness if your guiding exposures/corrections are set 
very quickly (less than 1 second). If the guider sends several corrections per 
second to the mount, the mount’s movement may osculate due to the response 

Содержание StarShoot 52098

Страница 1: ...Astronomy Camera 52098 instruction Manual Providing Exceptional Consumer Optical Products Since 1975 IN 508 Rev A 08 13 Customer Support www OrionTelescopes com contactus Corporate Offices 89 Hangar W...

Страница 2: ...adcasting The SSAIO can even be used as a high resolution AllSky camera when used with an optional Fish Eye Lens with meteor detection and time lapse software sold separately Item 52052 All In One All...

Страница 3: ...nd Driver Installation Before the SSAIO can be used soft ware and camera drivers must be installed onto your computer Do not connect the camera to your computer before you have installed the software...

Страница 4: ...tware automatically 5 Windows may note that the driver has not passed Windows Logo testing This is normal Click the Continue Anyway button When the Wizard has completed click the Finish button Windows...

Страница 5: ...es that can only be done when the cam era color is disabled This format is much smaller in data size and produces a much faster cap ture rate Image processing programs like MaxImDL or RegiStax can con...

Страница 6: ...els will change according to the temperature so this should also be taken into consid eration Note Dark frames must match the live image exposure and gain values in order to work correctly To test you...

Страница 7: ...ope is suitable for the SSAIO when imaging the planets The longer the focal length of the tele scope the larger and more detailed the images will appear Unlike deep space astro imaging you actually wa...

Страница 8: ...needed for the object you are imaging Imaging Tip To speed up the frame rate and to acquire a rough focus a lit tle quicker select resolution 640x480 2x2 binning mode This will increase the frame rate...

Страница 9: ...ment For best results a guide camera should also be used The longer the exposure the higher the amount of noise and hot pixels there fore automatic dark frame subtraction can be used to calibrate imag...

Страница 10: ...unted on top of or beside the main imaging scope Adjustable guide scope tube rings available from Orion are rec ommended and allow you to move the guide scope around without moving the main imaging sc...

Страница 11: ...PHD Guide icon and the calibration will begin The rest is auto matic Yellow crosshairs are displayed around the guide star box when the calibration starts The calibration is automatic and takes a few...

Страница 12: ...auto which will find the side of drift N S Dec Algorithm Settings that attempt to smooth the declination corrections to one consistent movement and can be used to resist switching directions in Dec C...

Страница 13: ...or at least five minutes and the star should begin to drift north or south 8 If the star drifts south the telescope mount is pointed too low If the star drifts north the telescope mount is pointed too...

Страница 14: ...en unplug and re plug the camera into the computer s USB port Now open Orion AstroCap and select camera resolution The Live Video Window should now appear indicating re established connection between...

Страница 15: ...Rate 30FPS 1280x960 44 FPS 1024x768 75FPS 800x600 106 FPS 640x480 200 FPS 320x240 A D Conversion On chip 12bit 8 bit output Thermoelectric cooling No IR Cut filter Yes Mounting 1 25 nose piece Weight...

Отзывы: