Orion SkyQuest XX12g Скачать руководство пользователя страница 23

23

Recalling a user-defined object

1.  See Step 1-2 of “Saving an object to the database” for 

details on how to access to the User Objects menu. 
Select Recall Object and press ENTER.

2.  Use the scroll buttons to browse through the User Object 

numbers until the number representing the object you 
wish to view is displayed. Press ENTER to show its 
coordinates. Press ENTER again and you’ll see “View 
object?” Press ENTER to slew the telescope to the 
object. The hand control will not respond if an unassigned 
User Object number is selected. Use the scroll buttons to 
choose another number and try again.

Hint: If the recalled object is below the horizon, the hand con-
troller will display “Below Horizon! Try another obj.” and auto-
matically return to the Recall Object menu.

Identifying an “Unknown” Object

The GoTo system has the ability to identify an unknown (to you) 
celestial object that the telescope it pointing at. Here’s how:
Press the ID button or scroll to IDENTIFY in the main menu 
and press ENTER

 to identify the object.

3.  The hand controller will display a list containing the clos-

est known object in different catalogs and its distance to 
the exact location where the telescope is pointed. Use 
the scroll buttons to view these objects.

4.  Press ESC

 to exit this function.

Linking with a Computer

The SkyQuest XXg can be connected to a computer via the 
supplied computer interface (serial) cable. Many commer-
cially available planetarium software programs can be used 
to control the SkyQuest XXg. Look for software that is com-
patible with the Orion SkyQuest XXg Dobsonians, Celestron 
NexStar5i/8i, or NexStar GPS series. Starry Night Pro is one 
such astronomy software package. The description below will 
lead you through the procedure on how to connect and dis-
connect the SkyQuest XXg to a computer.
1.  Align the base as described previously (see “Alignment 

for GoTo Operation”).

2.  Connect the supplied serial cable to the smaller of the 

two modular jacks (RJ-12) on the bottom end of the hand 
controller 

(Figure 29b). Connect the other end of the 

cable to the serial port of your computer. (If your com-
puter uses USB ports instead of serial ports, as most 
do these days, you will need the included USB-to-serial 
adapter cable.)

3.  In the planetarium software of your choice, choose “Orion 

SkyQuest GoTo or Celestron NexStar5i/8i or Celestron 
8/9/11 GPS (any of these will work) in the driver setup 
and follow the instructions provided by the program to 
connect the mount and computer. The SkyQuest XXg will 
be under the full control of your computer once the con-
nection is successfully established.

Disconnecting from the Computer

Follow the instructions provided by the planetarium software 
to close the connection to the hand controller.
On the hand controller, press ESC to resume normal hand 
controller operations.
NOTE: Do NOT disengage the SkyQuest XXg unit before 
you close the connection in the planetarium program. 
Doing so may cause some programs to freeze.

Updating the GoTo Hand Controller’s Firmware

From version 3.0 and up, the GoTo hand controller’s firmware 
can be updated over the internet. The firmware loader and 
firmware updates are available for download on the Orion 
website, OrionTelescopes.com

System Requirements

•  SynScan AZ GoTo hand controller version 3.0 or later
•  Windows95 or later
•  An available RS-232 COM port on the PC
•  Computer interface cable (supplied)
•  DC power supply (7.5V to 15V @ 100mA or greater output 

with 2.1mm tip positive plug)

Preparing the Computer for the Update

1.  Create a folder where you will store the files necessary 

for the update.

2.  On the OrionTelescopes.com website, go to the product 

page for your telescope. Look in the text description and 
you’ll see the Download Firmware Loader link. Click on it 
and save the Firmware Loader program to the folder you 
have created on your computer. You will need to download 
this program only once; after it is saved on your computer, 
only the firmware data file is needed for future updates.

3.  On the same web page, find the Download Firmware 

Files link and click on it. Download and save the firmware 
update data file to the folder you created. The file will be 
named OrionVxxxxAZ.ssf, where xxxx indicates the ver-
sion number of the firmware.

Updating the GoTo Hand Controller

1.  Plug the modular plug end of the computer interface cable 

into the middle jack in the hand controller. Plug the serial 
connector end of the cable to the COM port on your PC.

2.  Press and hold down the 0 and 8 numerical buttons simul-

taneously, then plug the power supply into the hand con-
troller’s DC power jack. The hand controller will beep and 
display “SynScan Update Ver. x.x” on the LCD screen.

3.  Run the Firmware Loader program on your computer.
4.  Click on the “Browse” box and select the OrionVxxxx.

ssf file location where it was saved previously on your 
computer.

5.  Click on the “Update” button, and the new firmware will 

begin loading into the hand controller. The Firmware 
Loader will show the progress of the update on your com-

Содержание SkyQuest XX12g

Страница 1: ...ail support telescope com Corporate Offices 831 763 7000 89 Hangar Way Watsonville CA 95076 2010 2012 Orion Telescopes Binoculars Orion SkyQuest XX12g XX14g GoTo Truss Tube Dobsonians 10137 XX12g 8964...

Страница 2: ...tube section 12 5mm Illuminated Pl ssl 1 25 eyepiece Eyepiece rack Dobsonian base Top baseplate Bottom baseplate Polyethylene foam dust guard EZ Finder II 35mm DeepView 2 eyepiece 2 Dual speed Crayfo...

Страница 3: ...g the primary mirror and mirror cell The XX14g model has a fourth box containing the truss poles which for the XX12g are included in the OTA box Before beginning assembly unpack each box and confirm t...

Страница 4: ...3 Counterweight mounting bolts XX14g only 6 Counterweights 2 2 lbs ea XX14g only 1 Cooling accelerator fan with battery holder XX12g only 1 Instruction manual not shown 1 Starry Night CD ROM Figure 2...

Страница 5: ...12g only feet are pre installed on XX14g 3 Feet wood screws 1 long XX12g only 1 SynScan AZ hand controller 1 Hand controller cable coiled 1 Azimuth motor connection cable 1 RS 232 computer cable 1 DC...

Страница 6: ...e motor housing the right side panel and the front panel For the initial assembly of the base you will need a Philips screwdriver To install the feet XX12g only feet are pre installed at the factory o...

Страница 7: ...wood screws and the 4mm hex key On the XX12g the left side brace is shorter than the right side brace On the XX14g the side braces are the same length Figure 8 Locations for insertion of connecting b...

Страница 8: ...g connect ing bolts with the threaded inserts in the baseplate Turn the connecting bolt hand knobs to fasten the side panel front panel structure to the baseplate Firmly tighten all 12 connecting bolt...

Страница 9: ...mirror is installed there will be no need to remove it except if clean ing is necessary see Section 11 Care Maintenance First the mirror will be installed in the tube then the upper and lower section...

Страница 10: ...erneath the screw heads Then gradually tighten both screws just until the metal plate is no longer loose Repeat this with the other two retaining clips Now the clips are properly tensioned 5 Assemblin...

Страница 11: ...t three of the six counterweights onto the rear cell of the lower tube section The XX12g does not utilize counterweights Installing the counterweights now will make the tube heavier to lift but they w...

Страница 12: ...con necting knob is facing upward Then the telescope tube can be held horizontally and just lowered into the base by gently sliding the tube s altitude hub into the altitude trun nion on the base Fig...

Страница 13: ...tube in place if it is too heavy or unwieldy for you to do by yourself 1 Grasp the rear end ring of the tube with one hand and one of the truss tubes with the other hand as shown in Figure 26 Lift th...

Страница 14: ...to see the dot without difficulty Typically a dimmer set ting is used under dark skies and a brighter setting is needed under light polluted skies or in daylight Aligning the EZ Finder II When the EZ...

Страница 15: ...components of an XX12g or XX14g Dobsonian short distances without assistance Of course having a helper will facilitate these activities but if or when you find yourself on your own for an evening obse...

Страница 16: ...To Hand Controller s Features and Functions The GoTo hand controller Figure 29a allows direct access to all the motion controls of the telescope and a database with some 42 000 pre set objects The con...

Страница 17: ...the RJ 12 connector of the cable into the jack labeled HC on the altitude motor housing see Figure 12 Plug the 12 volt DC power cable connected to your 12 volt DC power source into the Power jack on...

Страница 18: ...reference The descriptions below will lead you through step by step procedures for both alignment methods NOTE Before performing either of the alignment meth ods be sure that the EZ Finder II is preci...

Страница 19: ...ou have a star chart handy or are able to identify two bright stars visible in the night sky To perform the two star alignment you follow the same steps described for the Brightest Star alignment exce...

Страница 20: ...gh to land an object somewhere in the field of view of a low power eyepiece such as the DeepView 35mm If dur ing an observing session you discover that the GoTo point ing is off a bit the PAE function...

Страница 21: ...position The Custom position is the previously set parking position The hand controller will remember the coor dinates of a park position that you have specified PAE Allows user to fine tune star ali...

Страница 22: ...hen press ENTER to confirm 5 The hand control will prompt Re align Encoder complet ed on the LCD screen Press ENTER to confirm and finish the Re align Encoder procedure Handset Setting This submenu al...

Страница 23: ...ow the instructions provided by the program to connect the mount and computer The SkyQuest XXg will be under the full control of your computer once the con nection is successfully established Disconne...

Страница 24: ...rs with each other and with the mechanical axis of the telescope is called collimating Collimating is relatively easy to do and can be done in day light or at night Because the primary mirror is shipp...

Страница 25: ...ub of the 4 vaned spider several turns Now grasp the mirror to prevent it from rotat ing be careful not to touch the surface of the mirror while turning the center screw with a Phillips screwdriver Fi...

Страница 26: ...ocusing knob If the telescope is correctly collimated the expanding disk should be a perfect circle Figure 36 If the image is unsymmetrical the tele scope is out of collimation The dark shadow cast by...

Страница 27: ...supplied 35mm 2 eyepiece is 1500 mm 43x 35mm The magnification provided by the 12 5mm illuminated eye piece is 1500 mm 120x 12 5mm The maximum attainable magnification for a telescope is directly rela...

Страница 28: ...ill need to remove it from the telescope Before doing so remove the upper tube section from the assembled telescope Hold the secondary mirror sta tionary while loosening the center Phillips head screw...

Страница 29: ...face of the mir ror in the solution and gently swish it around for a minute or so 3 Now remove the mirror from the water and keep it tilted for a few seconds to allow the water to drain off 4 For the...

Страница 30: ...8 planets moon 212 named stars 55 well known double stars 20 well known variable stars 25 user defined objects SkyQuest XX14g GoTo Primary mirror 356mm diameter parabolic center marked Focal length 1...

Страница 31: ...31 Menu Tree...

Страница 32: ...32 Appendix A Time Zones of the World...

Страница 33: ...ckRateLowByte 0 0 b Negative Azm tracking 80 3 16 7 TrackRateHighByte TrackRateLowByte 0 0 c Positive Alt tracking 80 3 17 6 TrackRateHighByte TrackRateLowByte 0 0 d Negative Alt tracking 80 3 17 7 Tr...

Страница 34: ...34 Star Charts...

Страница 35: ...35...

Страница 36: ...36...

Страница 37: ...37...

Страница 38: ...38...

Страница 39: ...39...

Страница 40: ...rranty Repair 89 Hangar Way Watsonville CA 95076 Proof of purchase such as a copy of the original receipt is required This warranty does not apply if in Orion s judgment the instrument has been abused...

Отзывы: