- 66 -
- 67 -
ORION
Infinitely Expandable
*X:ThenumberofallXaxisline,1:1screenratio(Fullscreen)is“0x01”
*MakeallLCDdothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
Broadcastcommand:e.g.)Incaseof5x5MLCDformation
ⓐ
ⓑ
ⓒ
ⓓ
ⓔ
1
4
13
11
ⓐ
0x02(STX)
0xDD(CMD)
0x04(Length)
0x00(ID)
0x33(XY)
0x01(S)
0x05(X)
0x03(ETX)
ⓑ
0x02(STX)
0xDD(CMD)
0x04(Length)
0x00(ID)
0x33(XY)
0x0D(S)
0x05(X)
0x03(ETX)
ⓒ
0x02(STX)
0xDD(CMD)
0x04(Length)
0x00(ID)
0x22(XY)
0x04(S)
0x05(X)
0x03(ETX)
ⓓ
0x02(STX)
0xDD(CMD)
0x04(Length)
0x00(ID)
0x41(XY)
0x0B(S)
0x05(X)
0x03(ETX)
ⓔ
0x02(STX)
0xDD(CMD)
0x04(Length)
0x00(ID)
0x11(XY)
0x00(S)
0x01(X)
0x03(ETX)
-
Receive from MLCD
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0x01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
3.4. Infomation
-
Command for displaying the information on the screen (Input source and resolution by OSD)
-
It is available only on Power On (Operative) status.
-
CMD: 0x42
-
Send to MLCD
A. Normalcommand
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
0x42
0x02
Variable
0X01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
B. Broadcastcommand
STX
CMD
Length
Data: ID
ETX
Value
0x02
0x42
0x01
0x00
0x03
*AllLCDwilldothesameoperationsimultaneously.But,therewillbenoreturncommunication.(Onewaycommand)
-
Receive from MLCD
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
0x40
0x02
Variable
0X01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
3.5. Input-Mode Change
-
Command for changing input mode without screen scaling
-
It is available only on Power On (Operative) status.
-
CMD: 0xDD(DVI), 0XDE(PC), 0XE2(Video)
-
Send to MLCD
A. NormalCommand
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
B. BroadcastCommand
STX
CMD
Length
Data: ID
ETX
Value
0x02
Variable
0x01
0x00
0x03
*MakeallLCD(Master/Slave)dothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
-
Receive from MLCD
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
3.6. Global Offset
-
Command for removing the image data in seam area (On) or displaying all the data on the screen (Off)
-
It is available only on Power On (Operative) status.
-
CMD: 0x74(On), 0x73(Off)
-
Send to MLCD
A. NormalCommand
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
B. BroadcastCommand
STX
CMD
Length
Data: ID
ETX
Value
0x02
Variable
0x01
0x00
0x03
*MakeallLCD(Master/Slave)dothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
-
Receive from MLCD
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
MLCD