New Multi Function Controller
8
| ORION CO., LTD.
ORION CO., LTD. |
9
A. Power connector
Power connection for 5~9V
B. Service Port
It is a port for program download and debugging.
C. USB Port (Type B)
It is used for communication when the interface is changed to USB mode.
D. Ethernet Port
If it is directly connected to an external control device, "Crossover Network Cable" must be used.
If it is connected to a hub, "Straight-Through Network Cable" must be used.
E. 1 Channel Serial Port (R/A 9pin DSUB-female)
It is a connection port between Main board and sub board.
F. 4-Channel daisy-chain Serial Port (R/A 9pin DSUB-male)
It is used to connect with product. Each channel can used to connect 25 product daisy-chain.
2. Rear side
1. Connect RS-232C cable and a power adapter and install at the location of good remote
control reception. Use L-brackets to install at the side of the set.
2. Connect a computer and the New MFC with at least one of Ethernet, RS-232C, and USB
port and connect the product to the RS-232C output in the New MFC. Users can control
product with one of Ethernet, RS-232, USB, and IR remote controller.
3. Set the number of product units as instructed in <Configuration Mode> in the manual.
(Initial setting is 3X3)
4. The LED lamps in the New MFC indicate the previous or initial input source at first, please
select input source once again after power supply.
※
Caution : Please do not directly expose the IR Receiver to fluorescent lamps. It may cause
malfunction.
04.
New MFC Installation
L-Bracket
New MFC
A
B
C
D
E
F