background image

New Multi Function Controller

| ORION CO., LTD.

ORION CO., LTD. | 

9

A. Power connector

Power connection for 5~9V

B. Service Port 

It is a port for program download and debugging.

C. USB Port (Type B) 

It is used for communication when the interface is changed to USB mode.

D. Ethernet Port 

If it is directly connected to an external control device, "Crossover Network Cable" must be used. 

If it is connected to a hub, "Straight-Through Network Cable" must be used.

E. 1 Channel Serial Port (R/A 9pin DSUB-female) 

It is a connection port between Main board and sub board.

F. 4-Channel daisy-chain Serial Port (R/A 9pin DSUB-male) 

It is used to connect with product. Each channel can used to connect 25 product daisy-chain.

2. Rear side

1.  Connect RS-232C cable and a power adapter and install at the location of good remote 

control reception. Use L-brackets to install at the side of the set. 

2. Connect a computer and the New MFC with at least one of Ethernet, RS-232C, and USB 

port and connect the product to the RS-232C output in the New MFC. Users can control 
product with one of Ethernet, RS-232, USB, and IR remote controller.

3.  Set the number of product units as instructed in <Configuration Mode> in the manual. 

(Initial setting is 3X3)

4.  The LED lamps in the New MFC indicate the previous or initial input source at first, please 

select input source once again after power supply. 

Caution  :  Please do not directly expose the IR Receiver to fluorescent lamps. It may cause 

malfunction.

04. 

New MFC Installation

L-Bracket

New MFC

A

B

C

D

E

F

Содержание Multi Function Controller

Страница 1: ... display model only User s Manual 2012 02 24 Address 257 6 Gongdan dong Gumi si Gyeongsangbuk do Korea Tel 82 2 6678 8533 Fax 82 2 6678 8599 ORION CO LTD www oriondisplay net REMOTE CONTROL ON OFF INFO A SET DVIC1 DVIC2 INFO AUTO VIDEO S VIDEO HDSDI DVI PC DTV HDMI B BROADCAST ID SETTING ON OFF 1 2 3 4 5 6 7 8 0 9 DVI 1 DVI 2 OUTPUT FUNCTION INPUT SELECT New Multi Function Controller ...

Страница 2: ...Guide Information 5 Remote Controller For MFC 4250 5 Remote Controller For MFC 4260 MFC MLCD 6 New MFC 7 04 New MFC Installation 9 05 How to use Remote Controller 11 05 1 Power ON OFF 11 05 2 BROADCAST 11 05 3 AUTO Tracking MFC 4250 12 05 4 DVI Selector MFC 4250 12 05 5 Model Select MFC 4260 12 05 6 Mode Select MFC 4260 MFC MLCD 12 05 7 Communication Mode change 13 05 8 Input Selection MFC 4260 MF...

Страница 3: ... fire Carefully move the product not to give any shock It may cause product malfunction Please do not stack heavy objects on top of the product It may damage the product Please be careful not to soak unknown material or liquid into the product It may damage the product Please keep away from children s reach If they drop Remote Controller it may hurt the children or cause product malfunction Use th...

Страница 4: ...ns of product and DVI converter by a remote controller without additional applications MFC 4250 1 Note Use two 1 5V AAA type batteries Do not mix old and new batteries Do not mix different types or makes of batteries Mixed use of Alkaline Manganese or Re chargeable batteries are NOT recommended Only use two batteries of the same type and make 2 How to mount batteries Slide the cap at the rear side...

Страница 5: ... DVI Output Indicator MFC 4250 It indicates the current DVI output H Converting switch and indicator for communication Interface They are push button switches and indicators for communication interface Serial IR USB Ethernet 1 Front side REMOTE CONTROL ON OFF INFO A SET F1 F2 F3 F4 VIDEO DVI PC 117 84 B BROADCAST ID SETTING ON OFF 1 2 3 4 5 6 7 8 0 9 MODEL SELECT MODE SELECT INPUT SELECT E BOARD B...

Страница 6: ... can used to connect 25 product daisy chain 2 Rear side 1 Connect RS 232C cable and a power adapter and install at the location of good remote control reception Use L brackets to install at the side of the set 2 Connect a computer and the New MFC with at least one of Ethernet RS 232C and USB port and connect the product to the RS 232C output in the New MFC Users can control product with one of Eth...

Страница 7: ...depending on the model 05 How to use Remote Controller 05 1 Power ON OFF Every command is executed on all product sets 1 POWER ON 1 Press POWER ON button 2 Product is turned on as the PWR LED of the New MFC is turned on 2 POWER OFF 1 Press POWER OFF button 2 Product is turned off as the PWR LED of the New MFC is turned off 05 2 BROADCAST BROADCAST is a command to make all product perform Power On ...

Страница 8: ...CONTROL ON OFF INFO A SET F1 F2 F3 F4 VIDEO DVI PC 117 84 B BROADCAST ID SETTING ON OFF 1 2 3 4 5 6 7 8 0 9 MODEL SELECT MODE SELECT INPUT SELECT E BOARD 05 7 Communication Mode change There are four interface Ethernet USB RS 232C and IR Remote control Users can select the mode Press one of the four LED switches to select a mode you want 1 IR mode IR interface is designed to execute some product c...

Страница 9: ...SET DVIC1 DVIC2 INFO AUTO VIDEO S VIDEO HDSDI DVI PC DTV HDMI B BROADCAST ID SETTING ON OFF 1 2 3 4 5 6 7 8 0 9 DVI 1 DVI 2 OUTPUT FUNCTION INPUT SELECT HOR VER 2 Load the provided program by executing MFC Master exe in your computer MFC 4250 PIC Configuration exe A status window is popped up as shown in the following picture Serial port cable must be connected MFC 4250 ID 1 ID 4 ID 7 ID 2 ID 5 ID...

Страница 10: ...tch the Com Port and press OPEN and click From PC Match the Com Port and press OPEN and click Test for MFC MFC 4250 4 Type in IP Address MFC 4250 MFC 4250 5 Click SET TCP IP Info 6 Click GET TCP IP Info and Confirm the IP Address 7 Close the program MFC 4250 MFC 4250 ...

Страница 11: ... S VIDEO HDSDI DVI PC DTV HDMI B BROADCAST ID SETTING ON OFF 1 2 3 4 5 6 7 8 0 9 DVI 1 DVI 2 OUTPUT FUNCTION INPUT SELECT HOR VER 2 Load the provided program by executing MFC Master exe in your computer MFC 4250 PIC Configuration exe Match the Com Port and press OPEN and click From PC Match the Com Port and press OPEN and click Test for MFC MFC 4250 MFC 4250 3 Click GET TCP IP Info and check the n...

Страница 12: ... 2 DTV VIDEO S VIDEO HDSDI HDMI DVIC1 DVIC2 IR RS232 ETHERNET USB New MFC MSCS control PC RS 232C RS 232C IR RS232 ETHERNET USB DVI Signal Distributor UXGA UP TO 165MHz 4 USB mode USB communication is performed based on RS 232C specification too The external interface is USB type and it is converted to RS 232C internally 1 To execute USB mode press USB LED switch on the front side of New MFC 2 To ...

Страница 13: ...ber is shown as COM23 The number of each USB port may be changed 05 8 Input Selection MFC 4260 MFC MLCD 1 When the input source of the product is selected by MSCS program on the computer or the remote controller of New MFC the corresponding LED is turned on ID 1 ID 4 ID 7 ID 2 ID 5 ID 8 ID 3 ID 6 ID 9 DVI D IN OUT DVI D IN OUT DVI D IN OUT DVI D IN OUT DVI D IN OUT DVI D IN OUT DVI D IN OUT DVI D ...

Страница 14: ...l PC RS 232C RS 232C RS 232C DVI Signal Distributor UXGA UP TO 165MHz Video Signal Input Selection All inputs are executed as full screen mode 1 DVI 1 Press DVI button 2 DVI LED is on 3 Input source of product is switched to DVI MFC 4260 Input source of DVI Converter is switched to DVI MFC 4250 2 PC 1 Press PC button 2 PC LED is on 3 Input source of product is switched to PC MFC 4260 Input source ...

Страница 15: ...T ID SETTING ON OFF 1 2 3 4 5 6 7 8 0 9 DVI 1 DVI 2 OUTPUT FUNCTION INPUT SELECT HDMI Horizontal configuration 1 Press SET button 2 Press Left and Right buttons sequentially to enter the horizontal configuration mode 3 When the 2 LEDs at lower right corner of each 7 segment of Horizontal line in the New MFC are turned on the horizontal configuration mode is started 4 Use the number buttons to set ...

Страница 16: ...TION INPUT SELECT HOR VER HOR VER REMOTE CONTROL ON OFF INFO A SET DVIC1 DVIC2 INFO AUTO VIDEO S VIDEO HDSDI DVI PC DTV HDMI B BROADCAST ID SETTING ON OFF 1 2 3 4 5 6 7 8 0 9 DVI 1 DVI 2 OUTPUT FUNCTION INPUT SELECT REMOTE CONTROL ON OFF INFO A SET DVIC1 DVIC2 INFO AUTO VIDEO S VIDEO HDSDI DVI PC DTV HDMI B BROADCAST ID SETTING ON OFF 1 2 3 4 5 6 7 8 0 9 DVI 1 DVI 2 OUTPUT FUNCTION INPUT SELECT 05...

Страница 17: ...REMOTE CONTROL Power 1 5V Battery AAA 2EA Size 55 W x 190 L x 25 H mm Environmental Condition 10 C 40 C Weight 130g NEW MFC Voltage 5 9V DC 1 25W MAX Power Consumption 250mA Max 5 9V Size 58 W x 216 L x 46 H mm Environmental Condition 0 C 40 C 20 80 RH Weight 480g Adapter Size 35 W x 80 L x 86 H mm Input 90 264V 47 63Hz Output 5V 2000mA Output Jack 2 1ø Internal diameter Vcc 5 5ø External diameter...

Страница 18: ...New Multi Function Controller 32 ORION CO LTD MEMO ...

Отзывы: