Precautions For Safety 

Precautions for Use (Warning / Caution) 

      Warning

 

Indicates a potentially hazardous situation that, if the product is misused, may bring about death or   
serious injury to the operator. 

 

Installation must be done by specialized personnel. 

The product may fall down or drop if it is improperly installed.   

It may result in 

personal injury, electric shock or fire. 

Do not operate this product under abnormal conditions. 

Stop the operation when it is abnormal. Then, pull out the power plug or shut off the 
main power supply, and consult with our dealer or a specialized company. If the 
operation is continued under such conditions, 

it may cause electric shock or fire.

 

Shut off the main power supply before cleaning, maintenance and   

inspection. 

Shut off the main power supply before cleaning, maintenance, and inspection, and 
clearly post a sign on the power supply switch to indicate it is under cleaning, 
maintenance, and inspection.   

Failure to do so may result in electric shock or 

personal injury. 

Consult with a specialized company for maintenance and inspection. 

Inspect the power plug periodically. 

If the product is operated with the power plug, periodically inspect the power plug 
and confirm it is not covered with dust. The power plug must be fully inserted to the 
root of pins. If the power plug is covered with dust or not fully inserted, 

it may cause 

electric shock or fire

Be sure to install the protective device. 

Consult with a specialized company to install an earth leakage breaker. 

Failure to 

do so may cause electric shock or fire.

    Also, install an overload protection 

device (thermal relay).   

Operation without such a device may cause 

malfunction due to overload or fire. 

Contact with a specialized company when the earth leakage breaker is 

activated. 

When the earth leakage breaker is activated, contact with a specialized company.    If 
you force to turn on the power supply, 

it may cause electric shock or fire. 

Do not use this product outdoors. 

This product is intended for indoor use.    If the product is used outside and is 
exposed to wind or rain, the motor may suffer from incomplete insulation and may 
cause 

electric shock or fire.

 Caution 

Indicates a critical situation that, if the product is misused, may bring about injury to the operator or   
damage to the product. 

 

Do not use the machine over the specified pressure. 

If using the machine over the specified pressure, it may shorten the life of product   
and may cause failure, abnormal generation of heat or trouble.

 

Prohibition of operation with the vacuum pipe closed (V type and V

B type)

Do not operate the pump with the vacuum controller closed completely to close the   
vacuum pipe.    Negligence may cause an abnormal pump temperature rise resulting 
in a product failure, protective cover deformation or burn injury.     

Do not sit on, lean on, or place objects on this product. 

Do not place heavy objects or object containing water on the product, and do not get 
on it. If you get on the product, you may fall and be injured. If water spills, it may   
cause rust inside or poor insulation and 

may cause leakage or electric shock.

 

Содержание KRF110

Страница 1: ...ORION DRY PUMP CAUTION This product is intended only for industrial use Use with caution Read this Instruction Manual and follow the instructions described herein Please keep this Instruction Manual...

Страница 2: ...ge to the product Additionally the situation that is explained in Caution column may cause serious accident All safety information must be followed for safe operation After reading this manual keep it...

Страница 3: ...r Operation 6 Names of Components 7 Preparation and Confirmation 9 Operation Procedure 13 Maintenance and Inspection 16 Troubleshooting 18 Consumable Parts 20 Storage Not in Use for a Long Time 23 Dis...

Страница 4: ...n Do not operate this product while the main cover is removed Otherwise your hand s may be cut off or be seriously hurt because the cooling fan and the coupling rotate at high speeds Prevent the power...

Страница 5: ...a specialized company to install an earth leakage breaker Failure to do so may cause electric shock or fire Also install an overload protection device thermal relay Operation without such a device ma...

Страница 6: ...use electric shock or short circuit ignition due to degenerated insulation Be sure to wear personal protective equipment for cleaning and maintenance When you carry out cleaning or maintenance be sure...

Страница 7: ...and may cause generation of heat or deterioration Precautions For Safety Warning Label Position on the Product Warning Label Position on the Product The following warning labels are selected as most i...

Страница 8: ...pump away from oil water dust rain etc Also never lubricate the product Be sure to use under specified pressure or less Do not remove the main cover and top and bottom partition plates Removing these...

Страница 9: ...t Suction case Rubber packing Spring tube Filter Case Packing Knob nut Long cap 70 Gasket Delivery case Squeezing tube Muffler case Stay bolt Rubber packing Packing Knob nut Stay bolt Dry pump deal dr...

Страница 10: ...ide Plate B Blade Rotor Bearing Liner Bearing Retainer Liner Cylinder Bearing Retainer Filter Element F Gasket B Suction case Spring tube Filter Case B Packing Cap Delivery case Muffler case Stay bolt...

Страница 11: ...ct Upon receiving the product check it carefully for signs of shipping related damage like scratches deformation etc If you notice a problem contact with your dealer Be sure to check the name plate wh...

Страница 12: ...alve within 50cm from the inlet or outlet port of the pump No installation of check valve may cause malfunction Gauge controller KRF70 Be sure to install the gauge according to following procedure For...

Страница 13: ...dust inside the hose before piping 2 When intake air contains a big amount of dust or if dust grains are very fine 10 m or less use an appropriate filter in addition to the accessory filter 3 Install...

Страница 14: ...mark E or mark near the screw Select a copper wire with a nominal cross section bigger than the cross section shown in the example as grounding wire Motor rated output kW Nominal cross section mm2 2 2...

Страница 15: ...tten on the motor name plate for the set value Before using a machine that has not been used for a long period of time be sure to check that the power is off and then rotate the rotor fan motor fan et...

Страница 16: ...vacuum level and exhaust pressure Adjustment of vacuum level Vacuum controller 1 Turn the locking nut clockwise to unlock the control screw 2 Turn the control screw until the desired vacuum level is...

Страница 17: ...c pressure can exert its optimal performance life operation noise etc at a vacuum pressure within this range Use the pump within the recommended range unless the higher vacuum pressure is required Con...

Страница 18: ...eaning the filter element do not use organic solvents such as thinner alcohol benzine gasoline and kerosene It may result in explosion or fire Caution Be sure to wear protective wear When you carry ou...

Страница 19: ...rt of each part 3 Inspection of Piping Be sure to tighten the knob nut of filter case surely and ckeck that there is no air leakage clogging or loosening in the piping Inspection period Contents Once...

Страница 20: ...s under maintenance Failure to do so may result in electric shock or personal injury Consult with a specialized company for maintenance and inspection Caution Be sure to wear protective wear When you...

Страница 21: ...noise is occurred because the pressure is out of allowable range Return the pressure to the applicable pressure range Excessive exhaust pressure causes an abnormal noise Adjust the exhaust resistance...

Страница 22: ...side Delivery side Parts Number 03042561010 04000020010 Quantity unit 2 Inspection period At the time of removal of Suction case to Delivery case Replacement criterion When it was damaged or crushed...

Страница 23: ...10 04101504010 04100653010 Quantity unit 6 6 6 Replace ment time 10 000 6 000 5 500 Bearing Parts Number 0A000332000 0A000332000 0A000333000 Quantity unit 2 2 2 Replace ment time 10 000 6 000 5 500 Co...

Страница 24: ...ne Pcs Unit 6 Bearing 2 Liner white 2 Liner black 2 Liner yellow 4 Liner red 6 Maintenance of plastic parts affecting operation safety Caution Replace the following plastic parts affecting operation s...

Страница 25: ...here it is protected from water oil and dust 3 Store the product in a dry and clean place 4 Store the product in an airy place where the ambient temperature is 40 degrees in Celsius or less 5 Do not s...

Страница 26: ...440V 60Hz 7 1 460V 50Hz Mass 2 Three phase 200V spec kg 75 120 Three phase 400V spec Operation noise Three phase 2 dB 67 68 73 74 74 75 74 76 76 77 Applicable environment Installation site Indoor Perm...

Страница 27: ...rmity This EC declaration of conformity applies only to models that are equipped with ORION specified 3 phase motors Models with single phase motors models without motors and those models where the CE...

Страница 28: ...26 Dimensional Outline Drawing KRF70 V 01 04 KRF70 VH 01 04 unit mm...

Страница 29: ...27 Dimensional Outline Drawing KRF70 B 01 04 KRF70 BH 01 04 unit mm...

Страница 30: ...28 Dimensional Outline Drawing KRF70 VB 01 04 KRF70 VBH 01 04 unit mm...

Страница 31: ...29 Dimensional Outline Drawing KRF110 V 01 04 unit mm...

Страница 32: ...30 Dimensional Outline Drawing KRF110 B 01 04 unit mm...

Страница 33: ...31 Dimensional Outline Drawing KRF110 VB 01 04 unit mm...