![Orion Dynamo Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/orion/dynamo/dynamo_instruction-manual_1652706003.webp)
3
replacing the spotlight Bulb
Should the spotlight bulb break or burn out, it can be replaced
with an H3, 12V, 55W halogen bulb, available at hardware
stores. Make certain the power switch is in the “OFF” position
before replacing the bulb.
To replace the bulb, unthread the spotlight head (Figure 1) by
turning it counterclockwise. Make certain the old bulb and the
reflector have had plenty of time to cool down before you touch
either one. Separate the reflector from the bulb as shown in
Figure 2. Remove the wire retaining clip and replace the bulb.
Replace the retaining clip and insert the bulb back into the
reflector. Rethread the entire assembly back into the Dynamo.
specifications
Primary DC output: Two 12V cigarette-lighter type sockets,
maximum 10 amp total, tip positive.
Primary DC output regulation: 10 amp circuit breaker.
Secondary DC output: 3V, 6V, and 9V output jacks, maximum
1 amp output, tip positive.
Secondary DC output regulation: 2 amp fuse.
Flashlight: 12V, .5 A Krypton bulb, with red filter.
Spotlight: H3, 12V, 55W Halogen bulb, 800,000 candlepower,
angle adjustable
Internal battery: 12V, 7 amp-hour rechargeable sealed lead-
acid battery
Recharging current requirements: 120V, 60Hz AC or 14.5 to
15.5V DC
Operating temperature: 32° F to 86° F
Weight: 8.4 lbs.
Dimensions: 11.3" x 9.3" x 5.2"
Reflector
Remove this clip
Bulb
Figure 2.
The spotlight reflector dish and bulb.
90‑day limited Warranty
This Dynamo is warranted against defects in materials or workmanship for a period of 90 days from
the date of purchase. This warranty is for the benefit of the original retail purchaser only. During this
warranty period Orion Telescopes & Binoculars will repair or replace, at Orion’s option, any warranted
instrument that proves to be defective, provided it is returned postage paid to: Orion Warranty Repair,
89 Hangar Way, Watsonville, CA 95076. If the product is not registered, proof of purchase (such as a
copy of the original invoice) is required.
This warranty does not apply if, in Orion’s judgment, the instrument has been abused, mishandled, or
modified, nor does it apply to normal wear and tear. This warranty gives you specific legal rights, and
you may also have other rights, which vary from state to state. For further warranty service information,
contact: Customer Service Department, Orion Telescopes & Binoculars, P. O. Box 1815, Santa Cruz,