background image

Alentec & Orion AB

 Grustagsvägen 4, SE-13840, Älta, SWEDEN · [email protected] · www.alentec.com

3

GENERAL / ALLMÄNT / GÉNÉRALITÉS

INSTALLATION / INSTALLATION

MECHANICAL INSTALLATION

EN

This equipment is designed to be installed directly in distribution line pipe. 

The meter has a 1/2" or 3/4" BSP connection at the inlet and outlet. It also 

includes an inlet flange and a flange at the outlet with seating for an O-ring 

seal. 

Never mount the meter between two rigid connections. Use a hose to make 

a flexible connection.

It is recommended to install a pressure relief system on the line to prevent 

damage from thermal expansion.

To prevent damage from dirt or solid particles it is recommended the 

installation of a 200-mesh strainer at the meter inlet.

Using fluids with high or low viscosity, as well as if working with high flows or 

very low flows, calibration may be required.

ELECTRICAL CONNECTION

The electronic board LED allows quickly display of the open (LED on) or 

closed (LED off) state of the solenoid valve. Ensure proper connection to the 

positive and negative poles of the electronic board. The power supply unit 

must not exceed 30 V.

1.  Remove the cover by removing the two screws.

2.  Connect the meter according to the diagram.

3.  Re-attach the cover.

MEKANISK INSTALLATION

SE

Denna utrustning är avsedd att installeras direkt i distributionsledningar. 

Mätaren har en 1/2" eller 3/4" anslutning vid in- och utlopp. Det finns även 

möjlighet till flänsanslutning med O-ringsspår.

Montera aldrig mätaren mellan två fasta rör. Använd en slang så att en 

flexibel anslutning bildas.

Vi rekommenderar att en tryckbegränsningsventil monteras i rörsystemet för 

att förebygga skador på grund av termisk expansion.

För att förebygga skador från smuts eller hårda partiklar rekommenderar vi 

att man installerar ett 200-mesh filter innan mätarens inlopp.

När man hanterar vätskor med hög eller låg viskositet, eller om man 

använder mätaren med väldigt högt eller lågt flöde kan en kalibrering vara 

nödvändig.

ELEKTRISK INKOPPLING

En LED på kretskortet indikerar om öppet (LED på) eller stängt (LED av) 

tappställe. Säkerställ att plus- och minuspolerna ansluts till rätt ställe. 

Strömförsörjningen får ej överstiga 30V.

1.  Öppna locket genom att skruva bort de två skruvarna.

2.  Anslut mätaren enligt kopplingsschemat.

3.  Återmontera locket.

Содержание 24736

Страница 1: ...840 Älta SWEDEN info alentec se www alentec com USER MANUAL BRUKSANVISNING Part No Art Nr Réf 24736 24772 24776 24766 LINE METER FOR OIL GLYCOL WINDSCREEN FLUID DEGREASER INBYGGNADSMÄTARE FÖR OLJA GLYKOL SPOLARVÄTSKA AVFETTNINGSMEDEL 105026E ...

Страница 2: ... line and connection to a monitoring equipment It is recommended that the flow rate measured is placed approximately in the middle of the operating range of the meter Operation with flow near the ends of the operating range may cause a decrease in measurement accuracy Mounting electrical installation commissioning and maintenance must be carried out by qualified staff Only use the unit for the pur...

Страница 3: ...ive poles of the electronic board The power supply unit must not exceed 30 V 1 Remove the cover by removing the two screws 2 Connect the meter according to the diagram 3 Re attach the cover MEKANISK INSTALLATION SE Denna utrustning är avsedd att installeras direkt i distributionsledningar Mätaren har en 1 2 eller 3 4 anslutning vid in och utlopp Det finns även möjlighet till flänsanslutning med O ...

Страница 4: ...IN EN 292 2 11 91 and has been declared in conformity with the EC Directive 2004 108 EEC Alentec Orion AB Grustagsvägen 4 SE 13840 Älta Sverige deklarerar genom detta certifikat att de omnämnda utrustningarna är i överensstämmelse med följande standarder eller normerande dokument TÜV S9211282 DIN 24558 10 91 DIN EN 292 2 11 91 och har blivit deklarerade i enlighet med EC Direktiv 2004 108 EEC Kris...

Отзывы: