Q I G
Quick Installation Guide
PRINTED ON RECYCLED PAPER
Q
uick
I
nstallation
G
uide
Version 1.0
Q I G
Specifications
S w i tc h
E N 5 0 1 5 5
I N D U S T R I A L
1. Launch the Internet Explorer and type in IP address of the device. The default static
IP address is
10.0.0.1
Follow the steps below to log in and access the system:
2. Log in with default user name and password (both are
).
admin
3. After logging in, you should see the following screen. For more information on
configurations, please refer to the user manual. For information on operating the device
using ORing’s Open-Vision management utility, please go to ORing website.
Resetting
Configurations
Power
Redundant Input Power
24~110 (16.8~137.5) VDC on M12 5-pin A-coding Male connector
≤17Watts, 24VDC/0.69A (17W), 36VDC/0.45A (16W), 72VDC/0.21A (15W), 110VDC/0.13A (15W)
Physical Characteristic
Enclosure
IP-30 Aluminum
Dimension (W x D x H)
260 (W) x 50 (D) x 220 (H)mm (10.24 x 1.97 x 8.66 inch.)
Weight (g)
Environmental
-40 to 85 C (-40 to 185 F)
o
o
Storage Temperature
5% to 95% Non-condensing
Operating Humidity
Regulatory Approvals
CE EMC (EN 55024, EN 55032), FCC Part 15 B, EN 50155(EN 50121-1, EN 50121-3-2)
EMC
EN 55024 (IEC/EN 61000-4-2 (ESD: Contact 6KV, Air 8KV),
IEC/EN 61000-4-3 (RS 80MHz to 1GHz: 20V/m, 1.4-2GHz:10V/m 1kHz 80% AM),
IEC/EN 61000-4-4 (EFT Power 2KV, Single 2KV), IEC/EN 61000-4-5 (Surge: Power 2KV, RJ45 2KV),
IEC/EN 61000-4-6 (CS 150K-80MHz: 10Vrms 1kHz 80% AM), IEC/EN 61000-4-8(PFMF),
IEC/EN 61000-4-11 (DIP))
EMS
IEC60068-2-27
Shock
IEC60068-2-31
IEC60068-2-6
Vibration
Free Fall
Warranty
5 years
EN60950-1(LVD)
Safety
Fault Contact
Relay
Relay output to carry capacity of 3A at 24VDC on M12 connector (5-pin M12 A-coding female)
Overload Current Protection
Reverse Polarity Protection
Present
Present
-25 to 70 C (-13 to 158 F)
o
o
Operating Temperature
ORing Switch Model
10/100/1000Base-T(X) Ports
in M12 Auto MDI/MDIX
Physical Ports
Technology
Ethernet Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX
IEEE 802.3ab for 1000Base-T
IEEE 802.3x for Flow control
IEEE 802.3ad for LACP (Link Aggregation Control Protocol)
IEEE 802.1p for COS (Class of Service)
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol)
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
2K (WAN port), 16K (LAN port)
MAC Table
8
Priority Queues
WAN-4 (8-pin female X-coding with 2 x bypass function included)
Store-and-Forward
Processing
Switch Properties
Switching latency: 0.9 us
Switching bandwidth: 24 Gbps
Throughput (packet per second): 17.857Mpps@64Bytes packet
Max. Number of Available VLANs: 256
VLAN ID Range: VID 1 to 4095
IGMP multicast groups: 128 for each VLA
Port rate limiting: User Define
Security Features
Enable/disable ports, MAC based port security
Port based network access control (802.1x)
VLAN (802.1Q) to segregate and secure network traffic
Radius centralized password management
SNMPv3 encrypted authentication and access security
Https / SSH enhance network security
Web and CLI authentication
Software Features
IEC 61375-2-5 TTDP (Train Topology Discovery Protocol)
IEC 61375-2-3 TRDP (Train Real-Time Data Protocol)
RSTP/MSTP (IEEE 802.1D/w/s)
NAT: N-1 NAT, 1-1 NAT
TOS/Diffserv supported
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging
IGMP Snooping
Port configuration, status, statistics, monitoring, security
DHCP Server/Client
SMTP Client
Network Redundancy
O-Ring (Pending)
O-Chain (Pending)
MSTP (RSTP/STP compatible)
TGRS-T120-M12X-BP2-WV
Up to 10K Bytes
Jumbo frame
RS-232 Serial Console Port
RS-232 in M12 connector (5 pin female A-coding) with console cable. 115200bps, 8, N, 1
(support backup unit)
Power Consumption(Typ.)
After installing the
and connecting cables, he green power LED
switch
t
should turn on. Please refer to the following tablet for LED indication.
LED
Color
Status
Description
PWR
Green
On
DC power module activated
Status
Green
On
System activated
R.M
Green
On
Device operating in Ring Master mode
Ring
Green
On
Ring enabled
Blinking
Ring structure is broken
Fault
Amber
On
Errors occur (i.e. power failure or port malfunctioning)
10/100/1000Base-T(X) Ethernet ports
LNK/ACT
Green
On
Port is linked
Blinking
Transmitting data
Speed
Green
On
Port is running at 1000Mbps
Off
Port is running at 10/100Mbps
1.865 Kg
EN 55032, CISPR32, EN 61000-3-2, EN 61000-3-3, FCC Part 15 B class A
EMI
EN 50155 (IEC 61373) compliant
Other
MTBF
155,786hrs
ORing Industrial Networking Corp.
Copyright© 2020 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oringnet.com
E-mail: [email protected]
LAN-8 (8-pin female X-coding)
1MB share
Packet Buffer Size
Reset Function
Reset Button
< 5 sec: System reboot, > 5 sec: Factory default
TGRS-T120-M12X-BP2-WV
TGRS-T120-M12X-BP2-WV
EN50155 managed router switch
http://10.0.0.1
To reboot the switch, press the
button less than 5 seconds.
Reset
To restore the switch configurations back to the factory defaults, press the
button
Reset
more than 5 seconds.