Specifications

S w i tc h

E N 5 0 1 5 5

I N D U S T R I A L

1. Launch the Internet Explorer and type in IP address of the device. The default static
IP address is

10.0.0.1

Follow the steps below to log in and access the system:

2. Log in with default user name and password (both are

).

admin

3. After logging in, you should see the following screen. For more information on
configurations, please refer to the user manual. For information on operating the device
using ORing’s Open-Vision management utility, please go to ORing website.

Resetting

Configurations

Power

Redundant Input Power

24~110 (16.8~137.5) VDC on M12 5-pin A-coding Male connector

≤17Watts, 24VDC/0.69A (17W), 36VDC/0.45A (16W), 72VDC/0.21A (15W), 110VDC/0.13A (15W)

Physical Characteristic

Enclosure

IP-30 Aluminum

Dimension (W x D x H)

260 (W) x 50 (D) x 220 (H)mm (10.24 x 1.97 x 8.66 inch.)

Weight (g)

Environmental

-40 to 85 C (-40 to 185 F)

o

o

Storage Temperature

5% to 95% Non-condensing

Operating Humidity

Regulatory Approvals

CE EMC (EN 55024, EN 55032), FCC Part 15 B, EN 50155(EN 50121-1, EN 50121-3-2)

EMC

EN 55024 (IEC/EN 61000-4-2 (ESD: Contact 6KV, Air 8KV),

IEC/EN 61000-4-3 (RS 80MHz to 1GHz: 20V/m, 1.4-2GHz:10V/m 1kHz 80% AM),

IEC/EN 61000-4-4 (EFT Power 2KV, Single 2KV), IEC/EN 61000-4-5 (Surge: Power 2KV, RJ45 2KV),

IEC/EN 61000-4-6 (CS 150K-80MHz: 10Vrms 1kHz 80% AM), IEC/EN 61000-4-8(PFMF),

IEC/EN 61000-4-11 (DIP))

EMS

IEC60068-2-27

Shock

IEC60068-2-31

IEC60068-2-6

Vibration

Free Fall

Warranty

5 years

EN60950-1(LVD)

Safety

Fault Contact

Relay

Relay output to carry capacity of 3A at 24VDC on M12 connector (5-pin M12 A-coding female)

Overload Current Protection

Reverse Polarity Protection

Present

Present

-25 to 70 C (-13 to 158 F)

o

o

Operating Temperature

ORing Switch Model

10/100/1000Base-T(X) Ports

in M12 Auto MDI/MDIX

Physical Ports

Technology

Ethernet Standards

IEEE 802.3 for 10Base-T

IEEE 802.3u for 100Base-TX

IEEE 802.3ab for 1000Base-T

IEEE 802.3x for Flow control

IEEE 802.3ad for LACP (Link Aggregation Control Protocol)

IEEE 802.1p for COS (Class of Service)

IEEE 802.1Q for VLAN Tagging

IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol)

IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)

IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)

2K (WAN port), 16K (LAN port)

MAC Table

8

Priority Queues

WAN-4 (8-pin female X-coding with 2 x bypass function included)

Store-and-Forward

Processing

Switch Properties

Switching latency: 0.9 us

Switching bandwidth: 24 Gbps

Throughput (packet per second): 17.857Mpps@64Bytes packet

Max. Number of Available VLANs: 256

VLAN ID Range: VID 1 to 4095

IGMP multicast groups: 128 for each VLA

Port rate limiting: User Define

Security Features

Enable/disable ports, MAC based port security

Port based network access control (802.1x)

VLAN (802.1Q) to segregate and secure network traffic

Radius centralized password management

SNMPv3 encrypted authentication and access security

Https / SSH enhance network security

Web and CLI authentication

Software Features

IEC 61375-2-5 TTDP (Train Topology Discovery Protocol)

IEC 61375-2-3 TRDP (Train Real-Time Data Protocol)

RSTP/MSTP (IEEE 802.1D/w/s)

NAT: N-1 NAT, 1-1 NAT

TOS/Diffserv supported

Quality of Service (802.1p) for real-time traffic

VLAN (802.1Q) with VLAN tagging

IGMP Snooping

Port configuration, status, statistics, monitoring, security

DHCP Server/Client

SMTP Client

Network Redundancy

O-Ring (Pending)

O-Chain (Pending)

MSTP (RSTP/STP compatible)

TGRS-T120-M12X-BP2-WV

Up to 10K Bytes

Jumbo frame

RS-232 Serial Console Port

RS-232 in M12 connector (5 pin female A-coding) with console cable. 115200bps, 8, N, 1

(support backup unit)

Power Consumption(Typ.)

After installing the

and connecting cables, he green power LED

switch

t

should turn on. Please refer to the following tablet for LED indication.

LED

Color

Status

Description

PWR

Green

On

DC power module activated

Status

Green

On

System activated

R.M

Green

On

Device operating in Ring Master mode

Ring

Green

On

Ring enabled

Blinking

Ring structure is broken

Fault

Amber

On

Errors occur (i.e. power failure or port malfunctioning)

10/100/1000Base-T(X) Ethernet ports

LNK/ACT

Green

On

Port is linked

Blinking

Transmitting data

Speed

Green

On

Port is running at 1000Mbps

Off

Port is running at 10/100Mbps

1.865 Kg

EN 55032, CISPR32, EN 61000-3-2, EN 61000-3-3, FCC Part 15 B class A

EMI

EN 50155 (IEC 61373) compliant

Other

MTBF

155,786hrs

ORing Industrial Networking Corp.

Copyright©  2020 ORing

All rights reserved.

TEL: +886-2-2218-1066
FAX: +886-2-2218-1014

Website: www.oringnet.com
E-mail: [email protected]

LAN-8 (8-pin female X-coding)

1MB share

Packet Buffer Size

Reset Function

Reset Button

< 5 sec: System reboot, > 5 sec: Factory default

TGRS-T120-M12X-BP2-WV

TGRS-T120-M12X-BP2-WV

EN50155 managed router switch

http://10.0.0.1

To reboot the switch, press the

button less than 5 seconds.

Reset

To restore the switch configurations back to the factory defaults, press the

button

Reset

more than 5 seconds.

Отзывы: