Power Input
The switch supports triple redundant power supplies which are
located on a 7-pin terminal block.
Insert the negative/positive wires into the V-/V+ terminals,
respectively.
To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
STEP 1:
STEP 2:
Version 1.0
Q I G
Configurations
After installing the device and connecting cables, the green power LED
should turn on. Please refer to the following tablet for LED indication.
LED indication table
Specifications
Wiring
For pin assignments for different types of cables, please refer to the following tables.
Media
C o nv ert e r
Media
C o nv ert e r
I N D U S T R I A L
ORing Media Converter Model
ITGMC-111GP+
1G/10GBase-T in RJ45 Auto
MDI/MDIX
Physical Ports
Technology
Ethernet standards
IEEE 802.3ae for 10Gigabit Ethernet
IEEE 802.3an for 10GBase-T
IEEE 802.3ab for 1000Base-T
IEEE 802.3z for 1000Base-X
Power
Input power
Power consumption(Typ.)
Dual 12 ~ 48 VDC voltage power inputs in 6 pin terminal block
8.6 Watts
Overload current protection
Reverse polarity protection
Present
Present on terminal block
Physical Characteristic
Enclosure
IP-30
Dimension (W x D x H)
40 (W) x 108 (D) x 154 (H)mm (1.57 x 4.25 x 6.02 inch)
Weight (g)
1
(*Note)
Jumbo Frame
10K
437g
Fault contact
Relay
Relay output to carry capacity of 1A at 24VDC at pin terminal block
Regulatory Approvals
FCC Part 15, CISPR (EN55022) class A
EMI
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge),
EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
EMS
IEC60068-2-27
Shock
IEC60068-2-6
IEC60068-2-32
Vibration
Free Fall
100/1000Base-X SFP port
1
Environmental
-40 to 85 C (-40 to 185 F)
o
o
Storage Temperature
Operating Temperature
5% to 95% Non-condensing
Operating Humidity
-20 to 60 C (-4 to 140 F)
o
o
MTBF
TBD
Warranty
5 years
1G/10G Base-T(X) RJ-45 Pin Assignments
Pin Number
Assignment
1
TD+
2
TD-
3
RD+
4
Not used
5
Not used
6
RD-
7
Not used
8
Not used
1G/10G Base-T MDI/MDI-X Pin Assignments
Pin Number
MDI port
MDI-X port
1
TD+(transmit)
RD+(receive)
2
TD-(transmit)
RD-(receive)
3
RD+(receive)
TD+(transmit)
4
Not used
Not used
5
Not used
Not used
6
RD-(receive)
TD-(transmit)
7
Not used
Not used
8
Not used
Not used
Fiber Cables
The device comes with a SFP fiber optical port. The fiber optical ports are in multi-
mode (0 to 550M, 850 nm with 50/125 m, 62.5/125
m fiber) and single-mode with
LC connectors. Please remember that the TX port of Switch A should be connected to
the RX port of Switch B.
LED
Color
Status
Description
PW1
Green
On
DC power module 1 activated
PW2
Green
On
DC power module 2 activated
Relay
Amber
On
Relay activated (closed)
Off
Relay de-activated (opened)
LED for SFP Port
LNK/ACT
Green
On
Port is linked
LED for RJ45 Port
LNK/ACT
Green
On
Port is linked
Speed
Green
On
Port is running at 10Gbps
Amber
On
Port is running at 1Gbps
ORing Industrial Networking Corp.
Copyright© 2017 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oring-networking.com
E-mail: [email protected]
*Note : 10GBase-T must use shielding twisted pair cable of Cat6a or above.
ITGMC-111GP+
ITGMC-111GP+
Industrial Gigabit Media Converter