![ORiNG IGS-9084GP-FB2-MM Скачать руководство пользователя страница 151](http://html1.mh-extra.com/html/oring/igs-9084gp-fb2-mm/igs-9084gp-fb2-mm_user-manual_1651952151.webp)
IGS-9084GP-FB2 Series User Manual
ORing Industrial Networking Corp
150
Input
: enable the 1 pps clock input
Disable
: disable the 1 pps clock in/out-put
External Enable
The box allows you to configure external clock output.
The following values are possible:
True
: enable external clock output
False
: disable external clock output
VCXO_Enable
The box allows you to configure the external VCXO rate
adjustment.
The following values are possible:
True
: enable external VCXO rate adjustment
False
: disable external VCXO rate adjustment
Clock Frequency
The box allows you to set clock frequency.
The range of values is 1 - 25000000 (1 - 25MHz).
Label
Description
Delete
Check this box and click
Save
to delete the clock instance
Clock Instance
Indicates the instance of a particular clock instance [0..3]
Click on the clock instance number to edit the clock details
Device Type
Indicates the type of the clock instance. There are five device
types.
Ord-Bound
: ordinary/boundary clock
P2p Transp
: peer-to-peer transparent clock
E2e Transp
: end-to-end transparent clock
Master Only
: master only
Slave Only
: slave only
Port List
Set check mark for each port configured for this Clock Instance.
2 Step Flag
Static member defined by the system;
true
if two-step Sync
events and Pdelay_Resp events are used