background image

PWR-1

PWR-2

V2+ V2-                      V1+ V1-

1A@24V

Q I G

Quick Installation Guide

Q

uick

I

nstallation

G

uide

Version 2.2

Q I G

Cable Types and Specifications:

For pin assignments for different types of cables, please refer to the following
tables.

10/100 Base-T(X) MDI/MDI-X

Pin Number

MDI port

MDI-X port

1

TD+(transmit)

RD+(receive)

2

TD-(transmit)

RD-(receive)

3

RD+(receive)

TD+(transmit)

4

Not used

Not used

5

Not used

Not used

6

RD-(receive)

TD-(transmit)

7

Not used

Not used

8

Not used

Not used

Note: “+” and “-” signs represent the polarity of the wires that make up each

wire pair.

10/100 Base-T(X) RJ-45

Pin Number

Assignment

1

TD+

2

TD-

3

RD+

4

Not used

5

Not used

6

RD-

7

Not used

8

Not used

Resetting

To reboot the switch, press the

button for 2-3 seconds.

Reset

To restore the switch configurations back to the factory defaults, press the

button for 5 seconds.

Reset

Wiring

The device  has  two  sets  of  power  inputs,  power input 1
and power input 2. Follow the steps below to wire redundant
power

Power inputs

The two relay contacts on the terminal block allow you to form fail close circuits.
The  relay  contacts will respond to user-configured events according to the wiring.

Relay contact

Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.

Grounding

Configurations

After installing the switch, the green power LED should turn on. Please refer to the
following tablet for LED indication.

1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is

192.168.10.1

2. Log in with default user name and password
(both are

).

After logging in, you should

admin

see the following screen. For more information
on

configurations, please refer to the user

manual. For information on operating the switch
using ORing’s Open-Vision management utility,
please go to ORing website.

Follow the steps to set up the card:

Specifications

Cable

Type

Max. Length

Connector

10BASE-T

Cat. 3, 4, 5 100-ohm

UTP 100 m (328 ft)

RJ-45

100BASE-TX

Cat. 5 100-ohm UTP

UTP 100 m (328 ft)

RJ-45

STEP 1:

Insert  the  negative/positive  wires  into  the  V-/V+ terminals,  respectively.

STEP 2:

To keep the wires from pulling loose, use a small flat-blade screwdriver

to  tighten  the  wire-clamp  screws  on  the  front  of the connector.

ORing Switch Model

IES-2050A

10/100 Base-T(X) Ports in RJ45 Auto
MDI/MDIX

Physical Ports

5

Technology

Ethernet Standards

IEEE 802.3 for 10Base-TX
IEEE 802.3u for 100Base-TX
IEEE 802.3x for Flow control
IEEE 802.1D for STP (Spanning Tree Protocol)
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol)
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)

Fault Contact

Relay

Relay output to carry capacity of 1A at 24 VDC

Power

Redundant Input power

Power consumption(Typ.)

Dual DC inputs, 12~48VDC on 6-pin terminal block

Overload current protection

Reverse polarity protection

Present

Present on terminal block

Physical Characteristic

Enclosure

IP-30

Metal (non UL certified)

Dimension (W x D x H)

26.1 mm (W) x 95 mm (D) x 144.3(H) mm (1.03 x 3.74 x 5.68 inch.)

Weight (g)

Environmental

-40 to 85 C (-40 to 185 F)

o

o

Storage Temperature

MAC Table

1K

≤4Watts, 12VDC/0.29A (3W), 24VDC/0.14A (3W), 48VDC/0.08A (4W)

* Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201 power supply only.
* Fourni par la source SELV évaluée uniquement par l'alimentation UL 61010-1 or 61010-2-201.

395 g

Priority Queues

4

Processing

Store-and-Forward

Switch Properties

Switching latency: 8.94 µs
Switching bandwidth: 1Gbps
Throughput (packet per second): 76.19Mpps@64Bytes packet
VLAN: Port based

Security Features

Enable/disable ports,
VLAN to segregate and secure network traffic

Software Features

STP/RSTP (IEEE 802.1D/w)
Redundant Ring (O-Ring) with recovery time less than 10ms over 250units
DHCP Client
Port base VLAN
LLDP (Link Layer Discovery Protocol)
Port configuration, status, statistics, monitoring, security
SNMP v1/v2c /v3 and private MIB support

Network Redundancy

O-Ring
O-Chain
Fast recovery
RSTP/STP

-40 to 75 C (-40 to 167 F)

o

o

Operating Temperature

5% to 95% Non-condensing

Operating Humidity

Regulatory Approvals

CE EMC (EN 55024, EN 55032, EN 61000-6-2, EN 61000-6-4), FCC Part 15 B

EMC

EN 55024 (IEC/EN 61000-4-2 (ESD: Contact 4KV, Air 8KV), IEC/EN 61000-4-3 (RS: 3V),
IEC/EN 61000-4-4 (EFT Power 0.5KV, Signal 0.5KV), IEC/EN 61000-4-5 (Surge: Power 0.5KV, RJ45 0.5KV),
IEC/EN 61000-4-6 (CS: 3V), IEC/EN 61000-4-8(PFMF), IEC/EN 61000-4-11 (DIP))

EN 61000-6-2 (IEC/EN 61000-4-2 (ESD: Contact 4KV, Air 8KV), IEC/EN 61000-4-3 (RS: 10V),
IEC/EN 61000-4-4 (EFT Power 2KV, Signal 1KV), IEC/EN 61000-4-5 (Surge: Power 0.5KV),
IEC/EN 61000-4-6 (CS: 10V), IEC/EN 61000-4-8(PFMF), IEC/EN 61000-4-11 (DIP))

EMS

IEC60068-2-27

Shock

IEC60068-2-31

IEC60068-2-6

Vibration

EN 60950-1 (LVD)

Safety

Free Fall

MTBF

1796601.9604 hrs

PRINTED  ON  RECYCLED  PAPER

SWITCH

I N D U S T R I A L

Industrial Lite-Managed Switch

DIP-Switch setting

P.F.

Trigger alert when power fails (

On

: Enable,

Off

: Disable function)

R.E.

Enable/Disable O-Ring function (

On

: Enable,

Off

: Disable)

R.M.

Enable/Disable Ring Master Mode (

On

: Enable,

Off

: Disable)

R.S.

Select O-Ring redundant port (

On

: ring port set to port-5 and port-6,

Off

: ring port set to port-1 and port-2)

LED

Color

Status

Description

P1

Green

On

Power module 1 is activated

P2

Green

On

Power module 2 is activated

R.M

Green

On

System running in Ring Master mode

Ring

Green

On

System running in Ring mode

Blinking

Ring structure is broken (i.e. part of the

ring is disconnected)

Fault

Amber

On

Faulty relay (power failure or port

malfunctioning)

10/100Base-T(X) Fast Ethernet ports

LNK

/ACT

Green

On

Links are connected

Blinking

Transmitting data

Duplex/

Collision

Amber

On

Full-duplex mode

Off

Half-duplex mode

Blinking

Half-duplex and collision occurred

IES-2050A

IES-2050A

Packet buffer

1Mbits

EN 55032, EN 61000-6-4, CISPR32, EN 61000-3-2, EN 61000-3-3, VCCI class A, FCC Part 15 B class A

EMI

Warranty

5 years

ORing Industrial Networking Corp.

Copyright©  2015 ORing

All rights reserved.

TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Address 3F

No 542 2 Zhongzheng Rd

Xindian Dist

New

:

.,

.

- ,

.,

.,

Taipei City 23148 Taiwan

,

Website: www.oringnet.com
E-mail: [email protected]

Contact for maintenance and repair service:

Warning [AVERTISSEMENT]

Take into consideration the following guidelines before wiring the device
[Tenez compte des directrices suivantes avant de câbler l’appareil.]
1. Terminal block is mating with Plug and suitable for 12-24AWG.
Torque value 4.5 lb-in.
[Le bornier est compatible avec les connecteurs et convient pour 12-24AWG.
Valeur de couple 4,5 lb-in.]
2. The temperature rating of the input connection cable should higher than 105°C
[La température de service nominale du câble d’entrée doit être supérieure à 105 °C]

* Indoor use and pollution degree II, it must be wiped with a dry cloth for clean up the

device and label.

* Utilisation en intérieur et degré de pollution II, il faut l'essuyer avec un chiffon sec pour

nettoyer l'appareil et son étiquette.

* Do not block air ventilation holes.
* Ne bouchez pas les orifices de ventilation.
* If the equipment is used in a manner not specified by the manufacturer, the protection

provided by the equipment may be impaired.”

* Si l’appareil est utilise d’une maniere non specifiee par le fabricant, la protection qu’il

apporte peut se voir diminuee.”

* Shall be mounted in the Industrial Control Panel and ambient temperature is not exceed

75 degree C

* doit être monté dans le panneau de commande industriel et la température ambiante ne

doit pas dépasser 75 degrés C

Up to 2000m

Operating Altitude

Отзывы: