IDS-5011F Series User’s Manual 

 

35 

 

ORing Industrial Networking Corp. 

 

 

5.2.1.1 System 

 
 Time 

(SNTP)

 

 

Figure 5-19 Time (SNTP) 

 

The following table describes the labels in this screen.     

Label 

Description 

Name 

You can set the name of DS.     

SNTP 

Enable the SNTP server.     

Time zone 

After you set the SNTP enable, select the time zone you located.     

Time server 

Input SNTP server domain name or IP address and Port.     

Console 

Telnet Console (SSH) is included for security reasons.    In some cases, you may need 

to disable this function to prevent unauthorized access from internet.    The factory 

default is enable. 

Table 5-12 Time (SNTP)

Содержание IDS-5011F Series

Страница 1: ...1F Series Version 1 0 May 2008 ORing Industrial Networking Corp 4F NO 3 Lane235 Baociao Rd Sindian City Taipei County 23145 Taiwan R O C Tel 886 2 2918 3036 Fax 886 2 2918 3084 Website www oring netwo...

Страница 2: ...IDS 5011F on wall 5 HARDWARE OVERVIEW 8 3 1 Front Panel 8 3 2 Front Panel LEDS 9 3 3 Top Panel 10 3 4 Bottom Panel 10 3 5 Rear Panel 12 CABLES 13 4 1 Fibers 13 MANAGEMENT INTERFACE 14 5 1 DS Tool 14 5...

Страница 3: ...IDS 5011F Series User s Manual 5 2 1 4 Save Reboot 51 5 3 Configuration by SSH Console 52 5 3 1 Connect to DS 52 TECHNICAL SPECIFICATIONS 53...

Страница 4: ......

Страница 5: ...eaking or host PCs failure Secondly the IDS 5011F provides dual redundant power inputs on DC power jack and terminal block IDS 5011F also provides NAT pass through function so that users are able to m...

Страница 6: ...XP 2003 VISTA 1 3 Hardware Features Redundant Power Inputs 12 48 VDC on terminal block and power jack Operating Temperature 10 to 60o C Storage Temperature 20 to 85 o C Operating Humidity 5 to 95 non...

Страница 7: ...DS 5011F on DIN Rail Each IDS 5011F has a Din Rail kit on rear panel The Din Rail kit helps IDS 5011F to fix on the Din Rail It is easy to install the IDS 5011F on the Din Rail 2 1 1 Mount IDS 5011F o...

Страница 8: ...sh the IDS 5011F toward the Din Rail until you heard a click sound Figure 2 2 2 2 Wall Mounting Installation Each IDS 5011F has another installation method for you A wall mount panel can be found in t...

Страница 9: ...IDS 5011F Series User s Manual 5 ORing Industrial Networking Corp 2 2 1 Mount IDS 5011F on wall Step 1 Remove Din Rail kit Figure 2 3...

Страница 10: ...can be found in the package to combine the wall mount panel Just like the picture shows below Figure 2 4 The screws specification shows in the following two pictures In order to prevent IDS 5011F fro...

Страница 11: ...IDS 5011F Series User s Manual 7 ORing Industrial Networking Corp Step 3 Mount the combined IDS 5011F on the wall Figure 2 6...

Страница 12: ...1 1 Product description of IDS 5011F 2 LED for PWR1 and system status When the PWR1 links the green led will be light on 3 LED for PWR2 and system status When the PWR2 links the green led will be ligh...

Страница 13: ...ed PWR1 Green Red Red blinking Indicates an IP conflict or DHCP or BOOTP server did not respond properly On DC power 2 activated PWR2 Green Red Red blinking Indicates an IP conflict or DHCP or BOOTP s...

Страница 14: ...p Panel The Top panel components of IDS 5011F are showed as below 1 Terminal block include PWR1 12 48V DC 2 Power Jack include PWR2 12 48V DC 3 100Base FX Ethernet interface Figure 3 2 3 4 Bottom Pane...

Страница 15: ...RXD RXD 2 RXD RXD RXD 3 TXD TXD TXD DATA 4 DTR TXD TXD DATA 5 GND GND GND GND 6 DSR 7 RTS 8 CTS 9 RI RS 232 mod act as DTE Table 3 2 Pin assignment 3 DIP Switch Termination for RS 422 485 DIP 1 DIP 2...

Страница 16: ...anual ORing Industrial Networking Corp 12 3 5 Rear Panel The rear panel components of IDS 5011F are showed as below 1 Screw holes for wall mount kit and DIN Rail kit 2 Din Rail kit 3 Wall Mount kit Fi...

Страница 17: ...orts The fiber optical port is multi mode 0 to 2 km 1310 nm 50 125 m to 62 5 125 m or single mode 0 to 30 km 1310 nm 9 125 m with SC connector Please remember that the TX port of IDS 5011F should be c...

Страница 18: ...ndows utility for DS series It supports device discovery device configuration group setup group firmware update monitoring functions etc It is easy for you to install and configure devices over the ne...

Страница 19: ...IDS 5011F Series User s Manual 15 ORing Industrial Networking Corp Step 2 When installation complete successfully then click OK Figure 5 2 Step 3 Check for your selection Figure 5 3...

Страница 20: ...roadcast to the network and search all available DS devices in the network The default IP address of device is 192 168 10 2 and selects the searching device you wish to use and press Add button You ca...

Страница 21: ...NTP server and Auto IP Report Figure 5 5 General settings The following table describes the labels in this screen Label Description Device Name location You can set the device name or related informat...

Страница 22: ...tion option show the device server status The report interval is 0 indicate disable this setting default But you can set the other IP or Port Security Figure 5 6 Security The following table describes...

Страница 23: ...tached in your network environment Your network administrator should provide you the IP address and related settings The IP address must be unique within the network otherwise DS will not have a valid...

Страница 24: ...assigned by a DHCP server in your network Static IP Address Manually assigning an IP address Subnet Mask All devices on the network must have the same subnet mask to communicate on the network Gatewa...

Страница 25: ...P trap or system log Figure 5 8 Notification The following table describes the labels in this screen Label Description SNMP Trap To notify events by SNMP trap Email Notification To notify events by Em...

Страница 26: ...Description Web Management Enable To enable management from Web Click Goto Web Management button to access web Telnet Management Enable To enable management by Telnet Click Goto Telnet Management butt...

Страница 27: ...describes the labels in this screen Label Description Browsing Browse the file and upgrade Upgrade Enable the firmware upgrade Table 5 5 Upgrade Firmware Save Load Figure 5 11 Save Load The following...

Страница 28: ...efault you need to press Reset button on the device Hardware restore Reboot Device Reboot the device server warm start Import Configuration Restore the previous exported configuration Export Configura...

Страница 29: ...will be hold until the delimiters are received or the option Flush Serial to Ethernet data buffer times out 0 means disable Factory default is 0 Flush Data Buffer After The received data will be queu...

Страница 30: ...ans disable Factory default value is 0 Table 5 7 Serial settings Service Mode Virtual COM Mode In Virtual COM Mode The driver establishes a transparent connection between host and serial device by map...

Страница 31: ...ction is effective for this setting Alive Check The serial device will send TCP alive check package in each defined time interval Alive Check to remote host to check the TCP connection If the TCP conn...

Страница 32: ...ed and try to connect with other hosts 0 indicate disable this function Factory default value is 0 If Multilink is configured only the first host connection is effective for this setting Alive Check T...

Страница 33: ...thod you have settled Startup or any character After the data has been transferred device can disconnect automatically from the server by using the TCP alive check time or Idle time settings Figure 5...

Страница 34: ...ive Check to remote host to check the TCP connection If the TCP connection is not alive the connection will be closed and the port will be freed 0 indicate disable this function Factory default is 0 C...

Страница 35: ...DS 5011F Series User s Manual 31 ORing Industrial Networking Corp Figure 5 15 UDP mode Notification Specify the events that should be noticed The events can be noticed by E mail SNMP trap or system lo...

Страница 36: ...ipment is powered off A Notification will be sent RI changed When RI Ring Indicator signal changes it indicates that the incoming of a call A Notification will be sent CTS changed When CTS Clear To Se...

Страница 37: ...be trigger In Virtual COM Mode When Virtual COM is not available this event will be trigger A notification will be sent Table 5 11 Notification 5 2 Configuration by Web Browser 5 2 1 CONNECT TO THE WE...

Страница 38: ...Manual ORing Industrial Networking Corp 34 Step 3 Input the name and password then click OK Figure 5 17 Certificate Only if password is set Step 4 The system information will be shown as below Figure...

Страница 39: ...can set the name of DS SNTP Enable the SNTP server Time zone After you set the SNTP enable select the time zone you located Time server Input SNTP server domain name or IP address and Port Console Tel...

Страница 40: ...ironment Your network administrator should provide you with the IP address and related settings The IP address must be unique and within the network otherwise DS will not have a valid connection to th...

Страница 41: ...Mask Set the subnet mask to communicate on the network Gateway Enter the IP address of the router in you network DNS Server Enter the IP address of the DNS server to translate domain names into IP add...

Страница 42: ...Industrial Networking Corp 38 Authentication You can set the password to prevent unauthorized access from network Input the Old password and New password to change the password Factory default is no...

Страница 43: ...iguration The following table describes the labels in this screen Label Description Port Alias Remark the port to hint the connected device Interface RS232 RS422 RS485 2 wires RS485 4 wires Baud rate...

Страница 44: ...eout when no data has been transmitted When the timeout is reached or TX buffer is full 4K Bytes the queued data will be sent 0 means disable Factory default value is 0 Performance Throughput This mod...

Страница 45: ...way The data will be hold until the delimiters are received or the option Flush Serial to Ethernet data buffer times out 0 means disable Factory default is 0 Ethernet to serial Flush Data Buffer Afte...

Страница 46: ...onnections so that multiple hosts can send or receive data by the same serial device at the same time Figure 5 22 Virtual COM mode The following table describes the labels in this screen Label Descrip...

Страница 47: ...ion can support simultaneous connections are 5 default values is 1 Table 5 16 Virtual COM mode Not allowed to mapping Virtual COM from web Service Mode TCP Server Mode In TCP Server Mode DS is configu...

Страница 48: ...setting Alive Check The serial device will send TCP alive check package in each defined time interval Alive Check to remote host to check the TCP connection If the TCP connection is not alive the conn...

Страница 49: ...e freed and try to connect with other hosts 0 indicate disable this function Factory default value is 0 If Multilink is configured only the first host connection is effective for this setting Alive Ch...

Страница 50: ...ed serial device starts to send data Table 5 18 TCP client mode Service Mode UDP Client Mode Compared to TCP communication UDP is faster and more efficient In UDP mode you can Uni cast or Multi cast d...

Страница 51: ...host will be allowed to access the DS You can choose one of the following cases by setting the parameter 1 Only one host with a special IP address can access the device server IP address 255 255 255 2...

Страница 52: ...your name and password There are 4 Email addresses that you can specify to receive the notification SNMP Server configuration includes the SNMP Trap Server IP address Community Location and Contact Th...

Страница 53: ...mail SNMP trap or system log Figure 5 28 SMTP SNMP conf The following table describes the labels in this screen Label Description Hardware Reset Cold Start This refers to starting the system from powe...

Страница 54: ...hanged A Notification will be sent DSR changed When DSR Data Set Ready signal changes it indicates that the data communication equipment is powered off A Notification will be sent RI changed When RI R...

Страница 55: ...orp Eth1 link down When Eth1 link down a notification will be sent and Fault LED will be lighted Eth2 link down When Eth2 link down a notification will be sent and Fault LED will be lighted Table 5 19...

Страница 56: ...the five seconds on the device Hardware restore Restore Configuration Restore the previous exported configuration Backup Configuration Export the current configuration to a file Upgrade Firmware Upgr...

Страница 57: ...9 125 um Protocols ICMP IP TCP UDP DHCP BOOTP ARP RARP DNS SNMP MIB II HTTPS SSH Serial Interface Interface 1x RS232 RS422 4 2 Wire RS485 Which can be configured by DS Tool Connector Male DB9 Serial B...

Страница 58: ...ernet Green ON Blinking 100 Mbps Ethernet Serial TX RX LEDS Red Serial port is receiving data Green Serial port is transmitting data Power Requirements Power Input PWR1 12 48VDC in power jack PWR1 12...

Страница 59: ...nsole SSH console Console Command DS Tool for Windows NT 2000 XP VISTA Environmental Operating Temperature 10 to 60 C 14 to 140 F Operating Humidity 5 to 95 Non condensing Storage Temperature 20 to 85...

Отзывы: