Only qualified personnel should work with the product. Use the product correctly after 

thoroughly reading the section “Safety precautions.” In addition, be sure to observe the 

contents described in warning, caution, and note in this manual. The product described in 

this manual has been designed and manufactured to be incorporated in general industrial 

equipment. Do not use for any other purpose. Oriental Motor Co., Ltd. is not responsible for 

any damage caused through failure to observe this warning.

Safety precautions

The precautions described below are intended to ensure the safe and correct use of the 

product, and to prevent the customer and others from exposure to the risk of injury. Use 

the product only after carefully reading and fully understanding these instructions.

WARNING

Handling the product without observing the instructions 

that accompany a "WARNING" symbol may result in serious 

injury or death.

CAUTION

Handling the product without observing the instructions 

that accompany a "CAUTION" symbol may result in injury or 

property damage.

Note

The items under this heading contain important handling 

instructions that the user should observe to ensure safe use 

of the product.

Explanation of 
graphic symbols

 :

Indicates "prohibited" actions that must not be performed.

 :

Indicates "compulsory" actions that must be performed.

WARNING

 

Do not use the product in explosive or corrosive environments, in the 

presence of flammable gases, locations subjected to splashing water, or near 

combustibles. Doing so may result in fire, electric shock or injury.

 

Do not transport, install, connect, or inspect the product while the power is 

supplied. Always turn off the power before carrying out these operations. Injury 

may result.

 

Do not forcibly bend, pull or pinch the lead wire. Doing so may result in fire or 

electric shock.

 

Do not disassemble or modify the fan. Doing so may cause injury.

 

Only qualified and educated personnel should be allowed to perform 

installation, connection, operation and inspection/troubleshooting of the 

product. Handling by unqualified and uneducated personnel may result in fire, 

electric shock or injury.

 

Turn off the power in the event the overheat protection device (thermal 

protector) is triggered. Failure to do so may result in injury or damage to 

equipment, since the fan will start abruptly when the overheat protection 

device (thermal protector) is automatically reset.

 

The fan for Class

equipment. Be sure to ground the Protective Earth Terminal 

when installing the fan. Failure to do so may result in electric shock.

 

Install the fan in an enclosure. Failure to do so may result in electric shock or 

injury.

 

Be sure to keep the input power voltage within the specified range. Failure to 

do so may result in fire or electric shock.

 

Perform connections securely according to the connection diagram. Failure to 

do so may result in fire or electric shock.

 

Turn off the power in the event of a power failure. Otherwise, the fan will start 

unexpectedly when the power is restored. This may cause injury or damage to 

equipment.

CAUTION

 

Do not use the fan beyond its specifications, or electric shock, injury or damage 

to equipment may result.

 

Keep your fingers and objects out of the openings in the fan. This may cause 

injury.

 

Do not touch the motor part while operating or immediately after stopping. 

The surface is hot and it may cause a skin burn(s).

 

Do not lift the product by holding the rotating part (impeller) or lead wire of 

the fan. Doing so may cause injury.

 

Keep the area around the fan free of combustible materials. Failure to do so 

may result in fire or a skin burn(s).

 

Do not leave anything around the fan that would obstruct ventilation. Doing so 

may result in damage to equipment.

 

Do not touch the rotating part (impeller) when the fan is in operation. Doing 

so may cause injury. The use of the finger guard is recommended to ensure 

protection.

CAUTION

 

Immediately when trouble has occurred, stop operation and turn off the power 

supply. Failure to do so may result in fire, electric shock or injury.

 

Securely install the fan in an enclosure. Failure to do so may result in injury or 

damage to equipment.

 

The motor surface temperature of the fan may exceed 70 °C (158 °F) 

even under normal operating conditions. If the operator is allowed to 

approach the fan that is operating, attach a warning label as shown 

in the figure in a conspicuous position. Failure to do so may result in 

a skin burn(s).

Warning 

label

Checking the product

„

„

Package contents

Verify that the items listed below are included. Report any missing or damaged items to 

the branch or sales office from which you purchased the product.

 Fan  .................................. 1 unit

 Capacitor  ...................... 1 piece

(single-phase input only)

 OPERATING MANUAL 

(this document)  ......... 1 copy

 Capacitor cap  .............. 1 piece

(single-phase input only)

„

„

Checking the model name

Verify the model name of the purchased product against the model shown on the name 

plate of the product. Tell us the model name, product serial number, and manufacturing 

date shown on the name plate when you contact us.

MB  S  12  - JA

Series name

MB

MB 

Series

Type

S

type

Impeller Diameter

12

: Ø120 mm (Ø4.72 in.)

Power supply 

voltage

JA

: Single-phase 100 VAC 

UA

: Single-phase 110/115 VAC

JC

: Single-phase 200 VAC 

EC

: Single-phase 220/230 VAC

JS

: Three-phase 200 VAC 

ES

: Three-phase 220/230 VAC

Installation

„

„

Location for installation

Install the product in a well-ventilated location that provides easy access for inspection. 

The location must also satisfy the following conditions:

 

Inside an enclosure that is installed indoors 

 

Operating ambient temperature:−10 to +50 °C [+14 to +122 °F] (non-freezing)

*

When the intake air temperature (temperature of air to be sucked) exceeds 

+50 °C [+122 °F]: −10 to +40 °C [+14 to +104 °F].

(Range of intake air temperature: -10 to +90 °C [+14 to +194 °F])

 

Operating ambient humidity: 85 % or less (non-condensing)

 

Area that is free from an explosive atmosphere or toxic gas (such as sulfuric gas) or liquid

 

Area not exposed to direct sun

 

Area free of excessive amount dust, iron particles or the like

 

Area not subject to splashing water (storms, water droplets), oil (oil droplets) or other 

liquids

 

Area not subject to continuous vibration or excessive shocks

 

Area free of radioactive materials, magnetic fields or vacuum

 

Altitude Up to 1000 m (3300 ft.) above sea level

 

Area free of excessive electromagnetic noise (from welders, power machinery, etc.)When 

using near a switching circuit or high-frequency power supply, the induced current may 

flow inside the fan due to electromagnetic noise (conductive noise, radiative noise). If 

the induced current flows, the electric corrosion is caused in the bearings of the fan. As a 

result, it may generate the noise or shorten the service life of the products. Use the fan in 

the environment that the electromagnetic noise does not cause.

HF-3171-4

O P E R AT I N G   M A N U A L

Thank you for purchasing an Oriental Motor product.

This Operating Manual describes product handling procedures and safety precautions.

 

Please read it thoroughly to ensure safe operation.

 

Always keep the manual where it is readily available.

AC Centrifugal Blowers

MB Series  

Type

  

Содержание MB S Series

Страница 1: ...1 70 C 1 1 1 1 MB S 12 JA MB MB S S 12 120 mm JA 100 V UA 110 115 V JC 200 V EC 220 230 V JS 200 V ES 220 230 V 10 50 C 50 C 10 40 C 10 90 C 85 1000 m HF 3171 4 AC MB S...

Страница 2: ...4 PASF12 PAS12 z z M5 4 2 5 N m 4 M5 8 mm mm 61 40 0 2 4 5 5 81 95 0 2 M5 4 2 5 N m PASF12 M6 4 3 0 N m mm 90 0 2 110 95 0 2 65 4 M6 z z M6 3 3 0 N m mm 1 3 5 3 6 5 20 80 107 90 60 30 M4 1 3 N m PAS12...

Страница 3: ...1 0 N m 90 180 M6 4 3 0 N m 125 mm M5 4 2 5 N m FD12A M5 4 2 5 N m FGB12ES FGB12ES PASF12 FD12A 12 mm FGB12 FLB12 50 C M4 1 0 1 3 N m AWG18 0 75 mm2 4 1 mm 4 8 mm 9 5 mm AWG20 0 5 mm2 z z L N z z L1...

Страница 4: ...6 4 2 8 6 4 2 8 6 4 M3 3 0 4 N m OFF 130 5 C ON 85 20 C z z WEB WEB https www orientalmotor co jp 10 50 C 50 C 10 40 C 10 90 C 85 1000 m 10 60 C 85 3000 m UL CSA UL CSA No UL 507 UL E58377 CSA C22 2 N...

Страница 5: ...art impeller or lead wire of the fan Doing so may cause injury Keep the area around the fan free of combustible materials Failure to do so may result in fire or a skin burn s Do not leave anything aro...

Страница 6: ...11 5 lb in Installation pedestal PAS12 Note Be sure to assemble using the included screws Using a longer screw than the included screws may cause damage to product Installation direction When install...

Страница 7: ...parately The finger guard FGB12 and the filter FLB12 both sold separately are provided for intake side Use them in a condition where the intake air temperature is 50 C 122 F or below Connection Insula...

Страница 8: ...0 4 N m 3 5 lb in Note Be sure to assemble using the included screws Using a longer screw than the included screws may cause damage to product Locked rotor burnout protection The fan is equipped with...