background image

4

 

Unauthorized reproduction or copying of all or part of this manual is 

prohibited.

 

Oriental Motor shall not be liable whatsoever for any problems relating 

to industrial property rights arising from use of any information, circuit, 

equipment or device provided or referenced in this manual.

 

Characteristics, specifications and dimensions are subject to change without 

notice.

 

While we make every effort to offer accurate information in the manual, 

we welcome your input. Should you find unclear descriptions, errors or 

omissions, please contact the nearest office.

 

 is a registered trademark or trademark of Oriental Motor Co., 

Ltd., in Japan and other countries.

© Copyright ORIENTAL MOTOR CO., LTD. 2014

Published in December 2017

Technical Support  Tel:(800)468-3982

8:30 

A.M.

 to 5:00 

P.M.

, P.S.T. (M-F)

7:30 

A.M.

 to 5:00 

P.M.

, C.S.T. (M-F)

www.orientalmotor.com

Schiessstraße 44, 40549 Düsseldorf, Germany

Technical Support  Tel:00 800/22 55 66 22

www.orientalmotor.de

Tel:01256-347090

www.oriental-motor.co.uk

Tel:01 47 86 97 50

www.orientalmotor.fr

Tel:02-93906346

www.orientalmotor.it

Tel:+55-11-3266-6018

www.orientalmotor.com.br

• Please contact your nearest Oriental Motor office for further information.

4-8-1Higashiueno,Taito-ku,Tokyo 110-8536 

Japan

Tel:03-6744-0361

www.orientalmotor.co.jp

Tel:0800-060708

www.orientalmotor.com.tw

Singapore

Tel:1800-8420280

www.orientalmotor.com.sg

Tel:1800-806161

www.orientalmotor.com.my

Korea

Tel:080-777-2042

www.inaom.co.kr

Tel:1800-888-881

www.orientalmotor.co.th

Tel:400-820-6516

www.orientalmotor.com.cn

Tel:+91-80-41125586

www.orientalmotor.co.in

Hong Kong Branch

Tel:+852-2427-9800

Operation

The motor rotates when the power supply is turned on.

For protection against electric shock, do not turn on the power supply until the 

wiring is complete.

Note

Make sure that the motor case temperature does not exceed  

90 °C (194 °F) when operating the motor. Operation exceeding case 

temperature 90 °C (194 °F) may significantly deteriorate the coils and 

ball bearings of the motor and shorten the motor's life span. Motor 

case temperature can be measured by fixing a thermometer on 

the motor surface. It can also be measured using thermo tape or a 

thermocouple.

Time rating

Reversible motors have a 30 minutes rating. “30 min” is indicated on the nameplate.

Overheat protection for locked condition

This motor is equipped with one of the two features listed below to prevent the 

motor from burning out as a result of abnormal heating which may be caused 

by misapplication.

„

„

Thermally protected motors

"TP" is marked on the motor nameplate. This motor contains a built-in 

automatic return type thermal protector in the motor windings. If the motor 

internal temperature exceeds the specified value, the thermal protector is 

activated and the motor is stopped.

Always turn the power off before performing inspections.
Operating temperature of thermal protector:

Open (motor standstill) ............ 130±5 °C (266±9 °F)

Close (resuming operation) .... 85±20 °C (185±36 °F)

„

„

Impedance protection

"ZP" is stamped on the motor nameplate. The motor has higher coil impedance. 

When the motor goes into locked rotor condition due to a malfunction, coil 

impedance rises, suppressing input power to the motor and protecting the 

motor coil from burnout.

Troubleshooting

When the motor cannot be operated correctly, refer to the contents provided in this 

section and take appropriate action. If the problem persists, contact your nearest 

office.

Phenomena

Check items

Motor does not rotate.

Motor sometimes rotates 

and stops.

 

Check the power supply voltage.

 

Connect the power supply and the motor correctly.

 

Connect the supplied capacitor correctly.

 

If terminal blocks or crimp terminals are used, 

check them for poor connection.

 

Keep the load at or below the allowable value.

The motor rotates in the 

direction opposite to the 

specified direction.

 

Connect the supplied capacitor correctly.

 

The connection varies depending on the gear 

ratio of the gearhead.

 

The rotation direction is as viewed from the 

output shaft end. Check the reference direction.

Motor temperature 

abnormally high 

[Motor case temperature 

exceeds 90 °C (194 °F) ]

 

Check the power supply voltage.

 

With a single-phase motor, connect the supplied 

capacitor correctly.

 

Review the ventilation condition.

Noisy operation

 

Assemble the motor and gearhead correctly.

 

Assemble a gearhead of the same pinion type as 

the motor.

Regulations and standards

„

„

UL Standards, CSA Standards, CCC System

This product is recognized by UL under the UL and CSA Standards, and also 

certified by CQC under the China Compulsory Certification (CCC) system.

The motor model name represents the model that conforms to the standards.

Applicable standards

Applicable standards

Certification Body / File No.

UL 1004-1, UL 1004-2, UL 1004-3

UL /

UL File No.E64197, E64199

CSA C22.2 No.100, CSA C22.2 No.77
GB/T 12350

CQC

 

Thermal Class: 130 (B)

 

z

Standards for accessories

 

Capacitor: UL File No.E83671 (CYWT2), 

VDE License No.112847 (capacitors with a rated voltage of 250 VAC), 

114747 (capacitors with a rated voltage of 450 VAC)

 

Capacitor cap: UL File No.E56078 (YDTU2)

„

„

CE Marking

This product is affixed the CE Marking under the Low Voltage Directive.

 

z

Low Voltage Directive

Applicable standards

EN 60034-1, EN 60034-5, EN 60664-1
Momentary excess torque based on EN 60034-1

Model Momentary excess torque

Momentary excess torque represents 

a maximum torque that can maintain 

the operation for 15 seconds without 

stalling or abrupt speed change even 

if the torque is increased gently while 

operating at rated voltage and rated 

frequency.

2RK6 
3RK15

120% of the rated torque

4RK25

150% of the rated torque

5RK40 
5RK60

160% of the rated torque

5RK90

130% of the rated torque

Installation conditions 

(For EN standard)

Overvoltage category

, Pollution degree 2, Class

equipment

When the machinery to which the motor is mounted requires overvoltage 

category

specifications, install the motor in a cabinet that connect to power 

supply via an isolation transformer.

Motor temperature rise tests

Temperature rise tests required by the above standards are performed in a state 

that has been attached a heat radiation plate instead of a gearhead.

The size and material for the heat radiation plates are as follows.

[Size]

2RK6

: 115×115 mm (4.53×4.53 in.) 

3RK15

: 125×125 mm (4.92×4.92 in.)

4RK25

: 135×135 mm (5.31×5.31 in.) 

5RK40

: 165×165 mm (6.50×6.50 in.)

5RK60

5RK90

: 200×200 mm (7.87×7.87 in.)

[Thickness] 5 mm (0.20 in.)

[Material] Aluminum alloy

„

„

RoHS Directive

The products do not contain the substances exceeding the restriction values of 

RoHS Directive (2011/65/EU).

Содержание K Ⅱ Series

Страница 1: ...Do not disassemble or modify the motor This may cause electric shock or injury Caution Do not use the motor beyond its specifications Doing so may result in electric shock injury or damage to equipment Do not touch the motor during operation or immediately after stopping The surface is hot and may cause a skin burn s Do not lift the motor by holding the motor output shaft or motor lead wires Doing...

Страница 2: ...ving the gearhead from the motor Remove the hexagonal socket head screws 2 pieces assembling the motor and gearhead and detach the motor from the gearhead Hexagonal socket head screw Installing the gearhead to the motor 1 Keep the pilot sections of the motor and gearhead in parallel and assemble the gearhead with the motor while slowly rotating it clockwise counterclockwise At this time note so th...

Страница 3: ...del EPCR1201 2 Capacitor connection When crimp terminals are used use the FASTON terminals 187 Series TE Connectivity Use the supplied capacitor cap to insulate the capacitor terminal connection Capacitor 187 series Capacitor cap Note For lead wire connection use one lead wire for each individual terminal Connection method to a terminal block Remove the terminal box cover for the terminal box type...

Страница 4: ... input power to the motor and protecting the motor coil from burnout Troubleshooting When the motor cannot be operated correctly refer to the contents provided in this section and take appropriate action If the problem persists contact your nearest office Phenomena Check items Motor does not rotate Motor sometimes rotates and stops Check the power supply voltage Connect the power supply and the mo...

Отзывы: