9
Setting
The figure shows the factory setting.
×16/SPD1 switch
[Function setting switch]
No.1: SPD H/L switch
(Highest speed)
No.2: SPD2 EN switch
(Speed2 selection)
No.3: RUN switch
(Operating current rate)
No.4 to 6: ACC switch
(Acceleration time,
deceleration time)
×1/SPD2 switch
[Speed setting switch]
Two different operating speeds of high speed and low speed can be set in the
CVD
driver SC type.
It defines the high speed side as "Speed1" and the low speed side as "Speed2”
to be as follows.
y
Speed1 ...........Operating speed at the high speed side for when the M0 input
is turned OFF.
y
Speed2 ...........Operating speed at the low speed side for when the M0 input
is turned ON.
Speed1
Speed2
FWD input
RVS input
M0 input
Two setting patterns are available for the Speed1 and Speed2, and they vary
depending on the setting of the SPD2 EN switch (function setting switch
No.2).
Setting
pattern
SPD2 EN
switch
Speed setting method
Switch used
Pattern 1
OFF
Speed1:
Selected one from 256 different
speeds
Use in a combination of
×16/SPD1 and ×1/SPD2
Speed2:
Fixed to a 10% speed of the
Speed1
No use
Pattern 2
ON
Speed1:
Selected one from 16 different
speeds
×16/SPD1
Speed2:
Selected one from 16 different
speeds in a range of 0.5 to 50%
of the Speed1
×1/SPD2
Setting procedure
Select the highest speed of the Speed1.
Select the setting method of the Speed2.
Set the operation speed for the Speed1 and Speed2.
Set the acceleration time and deceleration time
Set the operating current rate
The setting is completed.
Conformity to the EMC Directive
Effective measures must be taken against the EMI that the motor and driver
may give to adjacent control-system equipment, as well as the EMS of the
motor and driver itself, in order to prevent a serious functional impediment in
the machinery. The use of the following installation and wiring methods will
enable the motor and driver to be compliant with the EMC directive. Refer to
p.11 for the applicable standards.
Oriental Motor conducts EMC measurements on its motors and drivers in
accordance with the "Example of motor and driver installation and wiring" in
the below.
The user is responsible for ensuring the machine's compliance with the EMC
Directive, based on the installation and wiring explained below.
•
Power supply
The
CVD
driver SC type is a product of DC power input. Use a DC power
supply (switched-mode power supply etc.) that conforms to the EMC
Directive.
•
Connecting the signal cable
Refer to "Prevention of noise propagation" on p.8.
•
How to ground
y
The cable used to ground the motor and driver must be as thick and short
as possible so that no potential difference is generated.
y
Choose a large, thick and uniformly conductive surface for the grounding
point.
y
Install the motor to the grounded metal plate.
•
Example of motor and driver installation and wiring
Motor
Driver
DC power
supply
Cable
clamp
Grounded panel
Motor cable
Programmable
controller
Power supply
cable
Signal cable
(connection cable)
Grounding
Grounding
Grounding
Grounding
Grounding
Grounding
is a shielded box.
Grounding Grounding
The driver uses parts that are sensitive to electrostatic charge. Take
measures against static electricity since static electricity may cause
the driver to malfunction or suffer damage.