Orientalmotor BLM5200HPK-5 Series Скачать руководство пользователя страница 5

5

„

„

Permissible radial load and permissible axial load

The radial load and the axial load on the gearhead output shaft must be 

kept under the permissible values listed below.

Note

Failure due to fatigue may occur when the gearhead bearings 

and output shaft are subject to repeated loading by a radial or 

axial load that is in excess of the permissible limit.

10 mm (0.39 in.)

20 mm (0.79 in.)

Distance from output shaft end

Axial load

Radial load

Gear 

ratio

Motor shaft 

rotation speed 

*

(r/min)

Permissible radial load [N (lb.)]

Permissible 

axial load 

[N (lb.)]

Distance from output shaft end

10 mm (0.39 in.) 20 mm (0.79 in.)

5

1500

521 (117)

663 (149)

39 (8.7)

3000

365 (82)

464 (104)

27.3 (6.1)

3600

261 (58)

332 (74)

19.5 (4.3)

10

1500

977 (210)

1244 (270)

88 (19.8)

3000

684 (153)

871 (195)

61.6 (13.8)

3600

489 (110)

622 (139)

44.0 (9.9)

20

1500

1243 (270)

1582 (350)

177 (39)

3000

870 (195)

1107 (240)

124 (27)

3600

622 (139)

791 (177)

88.5 (19.9)

30

1500

1824 (410)

2280 (510)

255 (57)

3000

1277 (280)

1596 (350)

179 (40)

3600

912 (200)

1140 (250)

128 (28)

50

1500

2032 (450)

2540 (570)

275 (61)

3000

1422 (310)

1778 (400)

193 (43)

3600

1016 (220)

1270 (280)

138 (31)

100

1500

2888 (640)

3496 (780)

422 (94)

3000

2022 (450)

2447 (550)

295 (66)

3600

1444 (320)

1748 (390)

211 (47)

200

1500

3483 (780)

4216 (940)

461 (103)

3000

2438 (540)

2951 (660)

323 (72)

3600

1742 (390)

2108 (470)

231 (51)

300 

450

1500

4461 (1000)

5174 (1160)

686 (154)

3000

3123 (700)

3622 (810)

480 (108)

3600

2231 (500)

2587 (580)

343 (77)

600 

1200

1500

5245 (1180)

5921 (1330)

824 (185)

3000

3672 (820)

4145 (930)

577 (129)

3600

2623 (590)

2961 (660)

412 (92)

 

*

The speed control range is 80 to 3600 r/min.

Connection

„

„

Connecting the motor and driver

Connect the connection cable (sold separately) to the motor and driver.

There are two types of connection cables which cable leading directions 

are different.

The following explains as an example of "leading in direction of 
output shaft."

Connection cable

Motor

Leading in opposite direction of output shaft

Leading in direction of output shaft

[ Cable leading direction ]

The connection procedures are 

explained as an example of this cable 

leading direction.

To driver

Note

Do not apply a strong force on the locking lever of the 

connector for motor connection. Applying a strong force on 

the locking lever may cause damage.

Locking lever

Содержание BLM5200HPK-5 Series

Страница 1: ...M Motor Connector Type Foot Mount Gearhead JB Gearhead Parallel Shaft Gearhead JV Gearhead Warning Do not disassemble or modify the motor and gearhead Doing so may result in electric shock injury or d...

Страница 2: ...the driver for the rotation direction of the motor output shaft and the setting method About rotation speed and gear ratio z z Maximum rotation speed 3600 r min Use the motor in conditions where the m...

Страница 3: ...method of the product Installation location Install the product in a well ventilated location that provides easy access for inspection Common conditions Indoors Operating ambient temperature 0 to 40...

Страница 4: ...d are used to attach the motor and gearhead temporarily When assembling be sure to use the hexagonal socket head screws which were removed Connecting with other equipment When installing a load on the...

Страница 5: ...540 570 275 61 3000 1422 310 1778 400 193 43 3600 1016 220 1270 280 138 31 100 1500 2888 640 3496 780 422 94 3000 2022 450 2447 550 295 66 3600 1444 320 1748 390 211 47 200 1500 3483 780 4216 940 461...

Страница 6: ...nded Two Protective Earth Terminals are provided on the driver Be sure to ground one of the Protective Earth Terminals Do not share the Protective Earth Terminal with a welder or any other power equip...

Страница 7: ...wer supply cable and other drive cables from the signal cables by means of double insulation Applicable Standards EN 60034 1 EN 60034 5 EN 60664 1 Installation conditions EN Standard For incorporating...

Страница 8: ...November 2017 Technical Support Tel 800 468 3982 8 30 A M to 5 00 P M P S T M F 7 30 A M to 5 00 P M C S T M F www orientalmotor com Schiessstra e 44 40549 D sseldorf Germany Technical Support Tel 00...

Отзывы: