4.  Connection and operation

• Connect the motor according to the 

"4. 2 Basic connection diagram"

 on page 6.

• Insulate all the wire connections, such as the connection between the motor and the capacitor connection.

  Capacitor cap are available to insulate capacitor connection.

2

1

3

Capacitor cap

Capacitor

Capacitor caps

 

 Pass the lead wires through the capacitor cap as shown in the figure.

 

 Connect the lead wires to the terminals or use terminal ends.

 

 Cover the capacitor with the capacitor cap.

Capacitor connection (For only single-phase motors)

A

B

C

D

187 

series

The capacitor internal wiring is as follows:

Capacitor terminals are internally electrically connected in twos; A-B and C-D for easy

connection.

For easy to install terminals use 187 series FASTON Terminals. (TE Connectivity)

For lead wire connection, use one lead wire for each individual terminal.

4. 1 Connection method to a terminal block

Terminal block

Protective earth terminal

Rubber sheet

Cable outlet of 

Terminal box cover

Cable

Cable clamp

Terminal box cover

To ensure safety, ground the motor using the protective earth terminal   inside the

terminal box.

Appropriate cable

  Cable diameter: Ø8.0 ~ Ø12.0mm (0.315 ~ 0.472inch DIA.)

Appropriate lead wire

  AWG18 (0.75mm

2

) min.

Appropriate crimp terminal

  Use the crimp terminal as below for connection (not supplied). Dimensions in millimeters (inch).

For connection to earth terminal

Tightening torque 1.0 ~ 1.5N·m (8.8 ~13.3lb-in)

  Ring terminal

 

Ø4.1 (.161DIA.) or more

9 (.354) or less

4.5 (.177) or less

For connection to terminal block

Tightening torque 0.8 ~ 1.0N·m (7.0 ~8.8lb-in)

  Ring terminal with insulation 

Fork terminal with insulation

 

Ø3.6 (.142DIA.) or more

7.2 (.283) or less

3.8 (.150) or less

6.2 (.244) or les

s

(after crimp)

 

3.6 (.141) or more

6.2 (.244) or less

6.2 (.244) or les

s

(after crimp)

Installation of the terminal box

Terminal cover screws

Terminal box cover

Cable outlet of 

terminal box cover

Terminal box

Attaching screws (4-M4)

Gasket

Terminal plate

• When sealing the terminal box cover, ensure that no scraps or particles get caught

  between the contact surfaces.

  Also, this terminal box is constructed to hold a gasket. If this gasket comes out of

  the box, please reseal it correctly on the box.

• Refer to the tightening torque table (left) to determine the appropriate tightening

  torque to use when fastening the terminal box cover, cable outlet of terminal box

  cover and so on.

• Cable entry is possible at any of the four sides of the terminal box.

  Undo the screws which attach the terminal box to the motor case (M4, four),

  position the terminal box so that the outlet faces in the desired direction and

  refasten the screws.

  In order to maintain a tight seal around the terminal box, a rubber sheet is used

  between the terminal box and terminal plate. Also this terminal box is constructed

  to hold a rubber sheet. If this rubber comes out of the box, please seat it correctly

  on the box.

Note

  To make shielding function fully effective, use a cable of an appropriate

 diameter.

Tightening torque

Terminal box cover

1.0 ~ 1.5N·m (8.8 ~ 13.3lb-in)

Cable outlet of terminal box cover

3.2 ~ 8.0N·m (28 ~ 70lb-in)

Cable clamp

0.2 ~ 0.3N·m (1.77 ~ 2.6lb-in)

Attaching screws

1.0 ~ 1.5N·m (8.8 ~ 13.3lb-in)

Содержание BH Series

Страница 1: ...ction device thermal protector is automatically reset The load holding force will be lost if the motor s overheat protection device thermal protector is activated Provide a safety measure by using a separate circuit interrupter to engage the brake Failure to do so may result in injury or damage to equipment The motor is ClassⅠ equipment Install the motor so as to avoid contact with hands or ground...

Страница 2: ...T A Round Shaft CH400CFAUL2 BHI62SMT G2 Pinion Shaft BH6G2 BH6G2 RA BH6G2 RH BHI62SMT A Round Shaft Gearheads are sold separately With combination types the motor and gearhead are pre assembled 1 The gear ratio appears at the position in the model number indicated by the box For example BHI62SMT 50 means that the model is equippedwith a 50 1 gear ratio For right angle shaft type there is RA or RH ...

Страница 3: ...r to the mounting plate with screws nuts and washers The mounting screws are not provided Be sure that no gaps are left between the motor and the surface of the mounting plate Illustration shows BH6G2 RH Note For BH6G2 RH when using the gearhead flange to mount the gearhead to equipment proper alignment between the hollow shaft inside dimension and the load shaft is necessary The diameter of the b...

Страница 4: ...isulphide grease etc to the load shaft and to the inner circumference of the hollow shaft Hollow shaft inside dimensions and recommended load shaft dimensions Unit mm inch Gearhead Model BH6G2 RH Hollow shaft inside dimensions H8 Ø25 0 033 0 9855DIA 9843DIA Recommended load shaft dimensions h7 Ø25 0 0 021 9843DIA 9834DIA After attaching the load attach the safety cover Note Do not apply excessive ...

Страница 5: ...4 5 177 or less For connection to terminal block Tightening torque 0 8 1 0N m 7 0 8 8lb in Ring terminal with insulation Fork terminal with insulation Ø3 6 142DIA or more 7 2 283 or less 3 8 150 or less 6 2 244 or less after crimp 3 6 141 or more 6 2 244 or less 6 2 244 or less after crimp Installation of the terminal box Terminal cover screws Terminal box cover Cable outlet of terminal box cover ...

Страница 6: ... CCW CW Motor Line Capacitor Magnetic brake SW1 ON Ro Co Ro Co ON SW2 CW CCW P E B U2 Z2 B U1 CW Motor Magnetic brake Ro Co Ro Co P E B V U B W Ro Co SW1 Line S R T V U W BHI62 MT A CCW CW Motor Line Capacitor Magnetic brake SW1 ON Ro Co Ro Co ON SW2 CCW CW P E B U2 Z2 B U1 CW Motor Magnetic brake Ro Co Ro Co P E B V U B W Ro Co SW1 Line R S T U V W Direction of rotation Direction of rotation To r...

Страница 7: ...otor above 90 C 194 F will shorten the life of the coil and the ball bearings Motor case temperature can be measured by fastening a thermometer to the motorʼs surface or with thermo tape Bring motors to a complete stop before switching the direction of rotation If you try to switch the direction of rotation before the motor has stopped it may not change or may require time This may damage the moto...

Страница 8: ...e bellow If the inspection shows that everything is normal but the motor and control unit still are not functioning correctly contact the nearest ORIENTAL MOTOR office Problem Things to check The motor does not rotate or motor rotates at low speed 1 Is the correct voltage being supplied to the motor 2 Are lead wires properly and firmly connected 3 Is the load too large 4 If lead wires have been ex...

Страница 9: ...traße 44 40549 Düsseldorf Germany Technical Support Tel 00 800 22 55 66 22 www orientalmotor de Tel 01256 347090 www oriental motor co uk Tel 01 47 86 97 50 www orientalmotor fr Tel 02 93906346 www orientalmotor it Tel 0800 060708 www orientalmotor com tw Singapore Tel 1800 8420280 www orientalmotor com sg Tel 1800 806161 www orientalmotor com my Korea Tel 080 777 2042 www inaom co kr 4 8 1 Higash...

Отзывы: