Object dictionary
125
3 E
therC
z
Non-excitation mode selection (413Dh)
This is used to select whether to enable the dynamic brake status or the free-run status when the motor is in a non-
excitation state. In the dynamic brake status, the motor windings will be in a state of being short-circuited inside the
driver, and the braking torque will generate. In the free-run status, the dynamic brake will be disabled, and the
braking torque will not generate.
Index
Sub
Name
Type
Access
PDO
Save
Range
Update
413Dh
00h
Non-excitation mode
selection
U8
RW
No
0, 1
(Initial value: 0)
A
Details of range
Setting value
Description
0
Dynamic brake status
1
Free-run status
z
Wrap positioning mode (414Fh)
This is used to set the operation mode for wrap positioning operation.
For details about operation mode, refer to “Operation mode of Profile position mode” on p.56.
Index
Sub
Name
Type
Access
PDO
Save
Range
Update
414Fh
00h
Wrap positioning mode
U8
RW
RxPDO
0, 1, 2, 3
(Initial value: 0)
B
Details of range
Setting value
Description
0
Wrap absolute positioning
1
Wrap proximity
2
Wrap forward direction
3
Wrap reverse direction
z
Main power mode (41FAh)
This is used to set the voltage mode of the main power supply. The voltage mode of the main power supply voltage is
discriminated in 50 ms after the main power supply is turned on. Set the Main power mode (41FAh) to "0: 24 VDC" or
"1: 48 VDC" when the main power supply starts up slowly or the voltage of the main power supply is unstable.
Index
Sub
Name
Type
Access
PDO
Save
Range
Update
41FAh
00h
Main power mode
INT8
RW
No
−1, 0, 1
(Initial value: −1)
D
Details of range
Setting value
Description
−1
Automatic discrimination (discriminates the input power supply voltage automatically.)
0
24 VDC mode
1
48 VDC mode
•
The optimal values in the motor control parameters are set in the driver according to the voltage
mode. If the voltage mode is not set correctly, torque may decrease or vibration may increase.
•
If −1 is set, after the control power supply is turned on, the voltage value is automatically
discriminated when the main power supply is turned on first. Be sure to shut off the control power
supply when changing the voltage of the main power supply.
•
The voltage mode actually operated can be checked with the Operation voltage mode (40B7h).