background image

 

Caution

 

 

• 

Do not use the motor beyond its specifications, or electric shock, 
injury or damage to equipment may result. 

• 

Do not touch the motor during operation or immediately after 
stopping. The surface is hot and may cause a burn. 

• 

Do not hold the motor output shaft or motor lead wires. This may 
cause injury. 

• 

Keep the area around the motor free of combustible materials in 
order to prevent fire or a burn. 

• 

To prevent the risk of damage to equipment, leave nothing around 
the motor that would obstruct ventilation. 

• 

To prevent bodily injury, do not touch the rotating parts (output 
shaft, cooling fan) of the motor during operation. 

• 

When an abnormality is noted, turn off the power immediately, or 
fire, electric shock or injury may occur. 

• 

The motor’s surface temperature may exceed 
70 °C, even under normal operating conditions. If 
a motor is accessible during operation, post the 
warning label shown in the figure in a 
conspicuous position to prevent the risk of skin 
burn(s). 

 

Warning label

• 

Dispose the product correctly in accordance with laws and 
regulations, or instructions of local governments. 

Preparation 

 

Checking the product 

Verify that the items listed below are included. Report any missing 
or damaged items to the branch or sales office from which you 
purchased the product. 

• 

Motor ............................................... 1 unit 

• 

OPERATING MANUAL ................ 1 copy 

 

Checking the model name 

Check the model number against the number indicated on the 
product. 

 

Model Model Model 

4IK25GN-FCH 4IK25GN-ECH 4IK25GN-SH 
4IK25AA-FCH 4IK25AA-ECH 4IK25AA-SH 
5IK40GN-FCH 5IK40GN-ECH 5IK40GN-SH 
5IK40AA-FCH 5IK40AA-ECH 5IK40AA-SH 
5IK60GE-FCH 5IK60GE-ECH 5IK60GE-SH 

 

5IK60A-FCH 5IK60A-ECH 5IK60A-SH 
5IK60GU-FCH 5IK60GU-ECH 5IK60GU-SH 
5IK90GE-FCH 5IK90GE-ECH 5IK90GE-SH 
5IK90A-FCH 5IK90A-ECH 5IK90A-SH 
5IK90GU-FCH 5IK90GU-ECH 5IK90GU-SH 

 

 

Installation 

 

Location for installation 

The motor is designed and manufactured for installation in 
equipment. 
Install it in a well-ventilated location that provides easy access for 
inspection. The location must also satisfy the following conditions: 

• 

Inside an enclosure that is installed indoors (provide vent holes) 

• 

Operating ambient temperature 

10 to +40 °C (+14 to +104 °F) (non-freezing) 

10 to +50 °C (+14 to +122 °F) for three-phase 200 V 

• 

Operating ambient humidity 85%, maximum (non-condensing) 

• 

Area that is free from an explosive atmosphere or toxic gas (such 
as sulfuric gas) or liquid 

• 

Area not exposed to direct sun 

• 

Area free of excessive amount dust, iron particles or the like 

• 

Area not subject to splashing water (storms, water droplets), oil 
(oil droplets) or other liquids 

• 

Area free of excessive salt 

• 

Area not subject to continuous vibration or excessive shocks 

• 

Area free of excessive electromagnetic noise (from welders, 
power machinery, etc.) 

• 

Area free of radioactive materials, magnetic fields or vacuum 

• 

1000 m (3300 ft.) or less above sea level 

 

How to install the motor 

• 

Round shaft type 

Drill holes on the mounting plate and fix the motor on the plate 
using screws, nuts, and washers (not supplied). Be careful there is no 
gap between the motor installation surface and the bracket. 

Washer

Nut

Motor

Mounting screw
(not provided) 

Mounting plate

 

First number in 

motor model 

Screw size 

Tightening torque [N·m (lb-in)]

4 M5 

2.5 

(22) 

5 M6 

3.0 

(26) 

 

Note

Do not insert the motor into the mounting hole at an 
angle or force it in, as this may scratch the flange pilot 
section and damage the motor. 

Отзывы: