2
Caution
•
Do not use the motor beyond its specifications, or electric shock,
injury or damage to equipment may result.
•
Do not touch the motor during operation or immediately after
stopping. The surface is hot and may cause a burn.
•
Do not hold the motor output shaft or motor lead wires. This may
cause injury.
•
Keep the area around the motor free of combustible materials in
order to prevent fire or a burn.
•
To prevent the risk of damage to equipment, leave nothing around
the motor that would obstruct ventilation.
•
To prevent bodily injury, do not touch the rotating parts (output
shaft, cooling fan) of the motor during operation.
•
When an abnormality is noted, turn off the power immediately, or
fire, electric shock or injury may occur.
•
The motor’s surface temperature may exceed
70 °C, even under normal operating conditions. If
a motor is accessible during operation, post the
warning label shown in the figure in a
conspicuous position to prevent the risk of skin
burn(s).
Warning label
•
Dispose the product correctly in accordance with laws and
regulations, or instructions of local governments.
Preparation
Checking the product
Verify that the items listed below are included. Report any missing
or damaged items to the branch or sales office from which you
purchased the product.
•
Motor ............................................... 1 unit
•
OPERATING MANUAL ................ 1 copy
Checking the model name
Check the model number against the number indicated on the
product.
Model Model Model
4IK25GN-FCH 4IK25GN-ECH 4IK25GN-SH
4IK25AA-FCH 4IK25AA-ECH 4IK25AA-SH
5IK40GN-FCH 5IK40GN-ECH 5IK40GN-SH
5IK40AA-FCH 5IK40AA-ECH 5IK40AA-SH
5IK60GE-FCH 5IK60GE-ECH 5IK60GE-SH
5IK60A-FCH 5IK60A-ECH 5IK60A-SH
5IK60GU-FCH 5IK60GU-ECH 5IK60GU-SH
5IK90GE-FCH 5IK90GE-ECH 5IK90GE-SH
5IK90A-FCH 5IK90A-ECH 5IK90A-SH
5IK90GU-FCH 5IK90GU-ECH 5IK90GU-SH
Installation
Location for installation
The motor is designed and manufactured for installation in
equipment.
Install it in a well-ventilated location that provides easy access for
inspection. The location must also satisfy the following conditions:
•
Inside an enclosure that is installed indoors (provide vent holes)
•
Operating ambient temperature
−
10 to +40 °C (+14 to +104 °F) (non-freezing)
−
10 to +50 °C (+14 to +122 °F) for three-phase 200 V
•
Operating ambient humidity 85%, maximum (non-condensing)
•
Area that is free from an explosive atmosphere or toxic gas (such
as sulfuric gas) or liquid
•
Area not exposed to direct sun
•
Area free of excessive amount dust, iron particles or the like
•
Area not subject to splashing water (storms, water droplets), oil
(oil droplets) or other liquids
•
Area free of excessive salt
•
Area not subject to continuous vibration or excessive shocks
•
Area free of excessive electromagnetic noise (from welders,
power machinery, etc.)
•
Area free of radioactive materials, magnetic fields or vacuum
•
1000 m (3300 ft.) or less above sea level
How to install the motor
•
Round shaft type
Drill holes on the mounting plate and fix the motor on the plate
using screws, nuts, and washers (not supplied). Be careful there is no
gap between the motor installation surface and the bracket.
Washer
Nut
Motor
Mounting screw
(not provided)
Mounting plate
First number in
motor model
Screw size
Tightening torque [N·m (lb-in)]
4 M5
2.5
(22)
5 M6
3.0
(26)
Note
Do not insert the motor into the mounting hole at an
angle or force it in, as this may scratch the flange pilot