Oregon Scientific WR103 Скачать руководство пользователя страница 9

EN

9

ABOUT RADIO CHANNELS

The NWR radio channels work in the same way as a
regular radio channel. All of the NWR transmission
stations operate on 1 of 7 frequencies.

The WR103N labels each frequency as a channel (A-G).
Once the radio frequency for a region has been selected,
the WR103N will receive voice and code information
from that station. The radio channel information is located
on the upper left hand corner of the LCD.

To change to radio channel:

1.

In any of the time displays, press and hold 

CHANNEL

for 2 seconds.

2.

Press   or   to switch between various channels.

3.

When the appropriate channel has been selected,
press

 MODE 

to confirm and return to the Clock-

Display mode.

NOTE

NOTE

A

162.400 MHz

B

162.425 MHz

C

162.450 MHz

D

162.475 MHz

E

162.500 MHz

F

162.525 MHz

G

162.550 MHz

Channel

Corresponding Radio Frequency

PROGRAMMING “SAME” COUNTY CODES

SAME county codes are required to receive weather and
environmental information, and need to be entered into
the WR103N. Up to 6 specific SAME codes can be
entered into 6 display fields.

The system can only alert the user to weather or

warning information after SAME county-code information
has been entered and enabled.

When the county code display is first entered, the user
will see a display field providing the option of selecting all
(ALL) or none [----] of the county codes. Selecting ALL
will set the unit so all of the warnings and weather
messages from a specified channel can be received. If
none [----] is selected the unit will receive warning or
weather information only from the specific regions that
have been specified with respective county codes.

It is recommended to select a SAME code field

between (1-6) and then enter a specific code for that
field. Selecting ALL will result in the unit giving warnings
for regions that are not relevant to the user. These
regions are quite large and can encompass about 5,000
square miles (13 sq km).

6 display fields permit up to 6 county codes to be entered.
The user can select less than 6 codes by leaving the
unused display fields empty.

Содержание WR103

Страница 1: ...ed by the NWR 7 Finding local NWR channels and county codes 7 About radio channels 9 Programming SAME county codes 9 Description of specific area message encoding codes 10 Radio volume 12 Clock and ca...

Страница 2: ...y LCD is easy to read Switching from 1 display mode to another is a 1 step procedure and the electro luminescent EL backlight ensures that nighttime warnings can be seen in low light levels ABOUT THE...

Страница 3: ...it channel setting mode 4 INDICATOR Red green LED indicates radio on off and alert status 5 COUNTY BUTTON Enables county mode Change county settings 0 6 Enter change the setting of a displayed county...

Страница 4: ...ases volume Turns selected daily alarm 1 or 2 on off Scrolls downward to select county code 6 0 3 ANTENNA Receives radio signals 4 SNOOZE BUTTON Enables the snooze function when alarm sounds Momentari...

Страница 5: ...dicators WARNING WATCH STATEMENT and TEST 5 Low battery warning icon 6 Alarm 1 and 2 icons GETTING STARTED Please note that the WR103N does not have an on off switch and that the LCD will light up onc...

Страница 6: ...nctions of time and date shows current time date or alarm time and status for either alarm 2 Radio Status Mode Displays information specific to the early warning functions of the radio To alternate be...

Страница 7: ...the radio on position and adjust the volume level if necessary MESSAGE CODES USED BY THE NWR When the NWR airs urgent warnings a digital code known as Specific Area Message Encoding SAME is included...

Страница 8: ...ntana Many counties have been subdivided into as many as 9 smaller subsections The numbers 1 to 9 in the far left column of the SAME code identifies specific subsections of a county If a county has no...

Страница 9: ...mental information and need to be entered into the WR103N Up to 6 specific SAME codes can be entered into 6 display fields The system can only alert the user to weather or warning information after SA...

Страница 10: ...es has their own 2 digit code County sub section code The last digit on the extreme left is the county sub section A county may be subdivided into nine sub sections each number between 1 9 represents...

Страница 11: ...TY to bypass the county code field 0 and advance to county code field 1 3 To enter the county code in this field press and hold COUNTY for 2 seconds The extreme left county code digit will flash 4 To...

Страница 12: ...ress or to make the minutes selection NOTE NOTE 6 When finished press COUNTY to advance to the next county code field or wait 9 seconds to automatically return to clock display mode RADIO VOLUME Befor...

Страница 13: ...W TO SET THE ALARMS The WR103N has 2 alarms alarm 1 and alarm 2 They can be used together or independently The Alarm icons are only displayed when alarm 1 or alarm 2 are active No icon s indicate that...

Страница 14: ...e alarm 1 or 2 Press MODE to enter alarm 1 or alarm 2 display followed by or When an alarm is activated the alarm time will be displayed in the alarm display In the Clock Display mode the respective a...

Страница 15: ...blic during times of emergency The EAS communication link is instant and can target the State National and LocalArea levels The EAS and NWS share the same digital signal used on the National Oceanic a...

Страница 16: ...WARNING For more information about the Emergency Alert System and event codes please visit www fcc gov eb eas or www nws noaa gov os eas_codes htm Nature of Activation Event Codes Message Nature of A...

Страница 17: ...counties in that state If the Test is cancelled due to the threat of severe weather the Test broadcast schedule will resume with the next available good weather day If you have any questions regardin...

Страница 18: ...damage The unit contains no user serviceable parts 5 Only use new batteries as specified in this instruction manual Do not mix new and old batteries as the old batteries may leak corrosive or hazardou...

Страница 19: ...scientific com about international FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interferenc...

Страница 20: ...ww oregonscientific com or on the warranty card for this product for all inquiries instead We Name Oregon Scientific Inc Address 19861 SW 95th Ave Tualatin Oregon 97062 USA Telephone No 1 800 853 8883...

Страница 21: ...EN 21 Weather Emergency Alert Monitor Model WR103N USER MANUAL...

Страница 22: ...EN 22 086L003504 038 2005 Oregon Scientific All rights reserved...

Отзывы: