Oregon Scientific WMR89 Скачать руководство пользователя страница 4

4

EN

G ET T I NG   S T A R T ED

  NO T E   

Install batteries in the remote sensors before the 

base station matching the polarities (+ and -).

  NO T E   

Use alkaline batteries for longer usage and 

consumer grade lithium batteries in temperatures below 

freezing.

S ET   U P   R EM O T E  W I ND   S ENS O R

The wind sensor takes wind speed and direction 

readings.  The sensor is battery operated. It is capable 

of transmitting data to the base station wirelessly within 

an approximate operating range of 100 meters (328 feet). 

T o   i n s e r t   b a t t e r i e s :

1

2

1.  Unscrew the anemometer from the wind sensor 

carefully.

2.  Insert batteries matching the polarities (+ / -) and 

replace the anemometer. 

S ET   U P   R EM O T E  T EM P ER A T U R E  /   H U M I D I T Y

S ENS O R

The remote sensor can collect data from up to 3 channels.

T o   s e t   u p   t h e   r e m o t e   s e n s o r :

1.  Slide open the battery door.
2.  Slide channel switch to select a channel (1/2/3).  Use 

a different channel for each sensor.

3.  Insert the batteries, matching the polarities (+ / -).
4.  Close the battery door.

S ET   U P   R A I N  G A U G E

The rain gauge collects rain and takes rainfall readings. 

The sensor can remotely transmit data to the base station.

T o   s e t   u p   t h e   r a i n   g a u g e :

1.  Remove screws and slide the cover off in an upwards 

motion. 

2.  Insert the batteries (2 x UM-3 / AA), matching the polarities 

(+ / -).

 

3.  Remove the fibre tape.

S ET   U P   B A S E  S T A T I O N

  NO T E   

Install batteries in the remote sensors before the 

base station matching the polarities (+ and -).

For continuous use, please install the AC adaptor.  The 

batteries are for back-up use only.

  NO T E 

  Make sure the adaptor is not obstructed and is 

easily accessible to the unit.

  NO T E 

 The base station and adaptor should not be 

exposed to wet conditions.  No objects filled with liquid, 

such as vases, should be placed on the base station 

and adaptor.

To completely disconnect from power, unplug adaptor 

from the mains.

T o   i n s e r t   b a t t e r i e s :

EU/UK

 

EU/UK

 

1.  Slide open the battery door.
2.  Insert the batteries, matching the polarities (+ / -).
3.  Close the battery door.

NO T E 

 

Do not use rechargeable batteries. It is recommended 

that you use alkaline batteries with this product for longer 

performance.

  NO T E 

 Batteries should not be exposed to excessive 

heat such as sunshine or fire.

Содержание WMR89

Страница 1: ...re humidity unit 10 Remote rain gauge 10 P r e c a u t i o n s 1 1 About Oregon Scientific 1 1 EU D e c l a r a t i o n o f C o n f o r m i t y 1 1 F C C s t a t e m e n t 1 1 D i s p o s a l i n f o r m a t i o n f o r u s e r s 1 2 I NT R O D U C T I O N Thank you for selecting the Oregon Scientific Full Wireless Weather Station Kit WMR89 WMR89A This system can provide you with weather informati...

Страница 2: ...es 2 Battery compartment 3 S EA R C H Searches for sensors or for the radio controlled clock signal 2 x AA UM 3 1 5V batteries 4 x screws Type B 1 x rain collector 4 R ES ET Returns unit to default settings 5 EU U K switch Select the nearest radio signal W M R 8 9 only 6 Micro USB socket 7 AC adapter socket L C D D I S P L A Y 1 2 A 3 B C D AVG GUST 1 No main power supply 2 U S B indicates a succe...

Страница 3: ...e past 24 hours rainfall 4 Barometer UV rainfall readings 5 UV level indicator 6 Barometric pressure UV rainfall units display 7 M A X barometer UV rainfall display 8 Barometricpressure UV rainfallhistoricalbarchartdisplay D C l o c k c a l e n d a r m o o n p h a s e a r e a 1 3 2 6 7 4 5 1 History mode display 2 AM PM 3 Time zone offset 4 Timestamp indicator 5 Clock signal reception indicator 6 ...

Страница 4: ... S ET U P R A I N G A U G E The rain gauge collects rain and takes rainfall readings The sensor can remotely transmit data to the base station T o s e t u p t h e r a i n g a u g e 2 1 1 Remove screws and slide the cover off in an upwards motion 2 Insertthebatteries 2xUM 3 AA matchingthepolarities 3 3 Remove the fibre tape S ET U P B A S E S T A T I O N NO T E Install batteries in the remote senso...

Страница 5: ... a l l t h e w i n d s e n s o r a b Secure the sensor connector in the desired location a Align the back of the sensor connector to an existing pole Secure in place by inserting the ends of the U bolt into the holes on the sensor connector and securing it with washers and bolts OR b Insert 4 type A screws into the holes of the sensor connector Screw firmly into place i e fence Slide wind vane ont...

Страница 6: ...llected rain T I P Press R ES ET button on back of the base station to erase all testing data B A C K L I G H T Press L I G H T to activate the backlight for 5 seconds C L O C K R EC EP T I O N This product is designed to synchronize its calendar clock automatically once it is brought within range of a radio signal W M R 8 9 EU DCF 77 signal within 1500 km 932 miles of Frankfurt Germany UK MSF 60 ...

Страница 7: ...t quarter Third quarter Waxing Gibbous Waning Crescent NO T E The moon phase displays in opposite orientation if you are in southern hemisphere A U T O S C A NNI NG F U NC T I O N T o a c t i v a t e t h e o u t d o o r t e m p e r a t u r e a n d h u m i d i t y a u t o s c a n f u n c t i o n 1 Press S EL EC T repeatedly to navigate icon to the Outdoor temperature reading in the or Humidity area...

Страница 8: ...imestamp records the date and time when storing the wind speed readings T o s e l e c t t h e w i n d s p e e d u n i t 1 Press S EL EC T repeatedly to navigate icon to the wind speed wind direction wind chill area 2 Press U NI T to switch between Kilometers per hour k p h Miles per hour m p h Meters per second m s Knots k n o t s T h e w i n d l e v e l i s s h o w n b y a s e r i e s o f i c o n...

Страница 9: ...to the barometer UV rainfall area 2 Press M O D E repeatedly to select 3 Press M A X M I N to toggle between current MAX UV index display The timestamp of when maximum UV was recorded is displayed accordingly in the clock area T o c l e a r m a x i m u m U V r e a d i n g 1 Press S EL EC T repeatedly to navigate icon to the barometer UV rainfall area 2 Press M O D E repeatedly to select UV display...

Страница 10: ...mp I ND O O R R EL A T I V E H U M I D I T Y Operating range 25 to 90 Displayed range 25 to 95 Accuracy 25 40 7 40 80 5 80 90 7 Memory Current Min and Max R A D I O C O NT R O L L ED A T O M I C C L O C K Synchronization Auto or disabled Clock display HH MM SS Hour format 12hr AM PM or 24hr Calendar DD MM or MM DD Weekday in 6 languages E G F I S R R EM O T E W I ND S ENS O R U NI T L x W x H 178 ...

Страница 11: ...tency between the English version and any other language versions the English version shall prevail EU D EC L A R A T I O N O F C O NF O R M I T Y Hereby Oregon Scientific declares that Full Wireless Weather Station Kit with USB upload model WMR89 WMR89A is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC A copy of the signed and dated Declaration ...

Страница 12: ...nd accumulators and waste batteries The barred symbol of the rubbish bin shown on the equipment indicates that at the end of its useful life the product must be collected separately from other waste Please note that the batteries rechargeable batteries must be removed from the equipment before it is given as waste To remove the batteries accumulators refer to the specifications in the user manual ...